Please contact us for the latest version.sales@ocaire.com, SS5YJ3 OTHER SIZE RATING, VALVE, SS5YJ3 MFLD SYJ3000, 1J, SS5YJ3 OTHER SIZE RATING, 0.44092 lb

base mounted or body ported styles.Bar stock type manifold for SYJ3000 valves, Supply and exhaust ports common (20, 31, 32, 41 types), Valves individually wired, Maximum 20 stations available as standard, 5 port sizes available, SS5YJ3 OTHER SIZE RATING, VALVE, SS5YJ3 MFLD SYJ3000, 1K, SS5YJ3 OTHER SIZE RATING, 0.66069 lb

base mounted or body ported styles.Bar stock type manifold for SYJ3000 valves, Supply and exhaust ports common (20, 31, 32, 41 types), Valves individually wired, Maximum 20 stations available as standard, 5 port sizes available, SS5YJ3 BUILT IN FITTING LESS THAN 1/4, VALVE, SS5YJ3 MFLD SYJ3000, UJ, SS5YJ3 BUILT IN FITTING LESS THAN 1/4, 0.99208 lb

Caution: SI unit for general purpose output block (EX500-Q 02 etc.) M3 x 18: 2 pcs. (Hexagon socket head cap screw (with SW)) : Please refer to the separate catalog regarding assembly and disassembly with other unit. Warning: WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.

PF2M7-B.eng:PF2M7-B.eng.qxd 21/04/09 14:02 1 Before Use Digital Flow Switch PF2M7## Wiring Wiring of connector Connections should only be made with the power supply turned off. Use separate routes for the product wiring and any power or high voltage wiring. Otherwise, malfunction may result due to noise.

Dynamic viscosity [m2/s] Viscosity [Pas] Density [kg/m3] Viscosity and dynamic viscosity are obtained by the formulas below. Dynamic viscosity [cSt] Viscosity [mPas] Density [g/cm3] 1 [mPas1 [cP] 13 Working Principle 1. When air is supplied, it passes through the switching valve and enters drive chamber B. 2.

Dynamic viscosity [m2/s] Viscosity [Pas] Density [kg/m3] Formulas below can be used for common units 1cP = 1mPas = 10-3Pas 1cSt = 1mm2/s = 10-6m2/s 13 Working Principle 1. When air is supplied, it passes through the switching valve and enters drive chamber B. 2.

Dynamic viscosity [m2/s] Viscosity [Pas] Density [kg/m3] Formulas below can be used for common units 1cP = 1mPas = 10-3Pas 1cSt = 1mm2/s = 10-6m2/s Pulsation Attenuating Capacity The process pump generates pulsation because it discharges a liquid using two diaphragms.

Bore size Hexagon socket head Appropriate tightening (mm) cap screw (mm) torque (Nm) 6, 10 M3 1.0810% 16 M4 2.4510% Do not use compressed air containing a lot of condensate, which 20, 25 M5 5.1010% can cause the operating failure of the product and other pneumatic 32 M6 8.0410% equipment. Ensure that fluid and ambient temperature are within the specified range.

Applicable model AMG150 AMG250 AMG350 AMG450 AMG550 AMG650 AMG850 Bracket assembly With cap bolt With spring washer BM51 BM52 BM53 BM54 BM55 BM56 BM57 Condition of inlet air Pressure: 0.7MPa Temperature: 25C Relative humidity: 100% How to Order AMG 250 03 J B Liquid water content (Water droplet content): 1.5g/m3 (ANR) Options Body size Compressed air flow: Rated flow of each model J Drain

bar)]Recommended flow m3/min(ANR)Weight gAN500-061603212 or less165

bar)]Recommended flow m3/min(ANR)Weight gAN500-061603212 or less165

bar)]Recommended flow m3/min(ANR)Weight gAN700-124408830 or less435

Tightening torque Thread Appropriate tightening torque Nm (kgfcm) M3 M5 0.3 to 0.5 (3 to 5) 1.5 to 2 (15 to 20) Wiring 1Polarity When DC power is to be connected to a solenoid valve equipped with light and/or surge voltage suppressor, check for polarity indications.

SY SYJ Specifications Max. operating pressure Min. operating pressure SX 0.8MPa 0.15MPa 5 to 50C 2.7mm 2(0.15) 180CPM VVQ1000-FPG-02 1set VQ1000-FPG-C6M5-D 2 pcs.

READY POWER OUT VALVE OUTPUT DC24V OV COM SOL.a SOL.b +24V SIG OV 7 10 4 20-M3 x 0.5 65 72 A view 82 0.2 92 87.6 58.4 62 8 35.5 A 1.15-39

KS KX 20 to 60C (No freezing) Flame resistant polypropylene (Equivalent to UL-94 standard V-0) Black Material Ambient temperature KM Color KF Model Applicable One-touch fitting Union elbow Union tee Straight union KQ2L06-00A KQ2T06-00A KQ2H06-00A Applicable exhaust valve N (Stations) Model M TMA-04 10 KEA06 H/DL L/LL TMA-06 8 KQ2L08-00A KQ2T08-00A KQ2H08-00A KEB06 KEA08 KEB08 KEC-02 KC TMA

DC 5 6 24 VDC 12 VDC Port size AC (50/60 Hz) Symbol Port size VP300 1/8 1/4 3/8 1/2 VP500 VP700 1 2 3 4 7 B 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] 240 VAC 24 VAC 01 02 03 04 Made to Order Nil Electrical entry Pilot exhaust port with piping thread (M3) specification (Refer to page 24).

Available in thread sizes from M3 to 1/2 in both inch (NPT) and metric R(PT) and with tube sizes from 3.2mm to 12mm OD (metric) and 1/8 to 1/2 OD (inch) and with optional elbow and universal style (increased flexibility) and meter-in and meter-out, these speed controls are designed to meet most applications.

Available in thread sizes from M3 to 1/2 in both inch (NPT) and metric R(PT) and with tube sizes from 3.2mm to 12mm OD (metric) and 1/8 to 1/2 OD (inch) and with optional elbow and universal style (increased flexibility) and meter-in and meter-out, these speed controls are designed to meet most applications.