Size SCFM 50 PSI 60 PSI 70 PSI 80 PSI 90 PSI 100 PSI 110 PSI 1/2" ID 20 1.8 1.3 1 0.9 0.8 0.7 0.6 30 5 4 3.4 2.8 2.4 2.3 2 40 10.1 8.4 7 6 5.4 4.8 4.3 50 18.1 14.8 12.4 10.8 9.5 8.4 7.6 60 23.4 20 17.4 14.8 13.3 12 70 28.4 25.2 22 19.3 17.6 80 34.6 30.5 27.2 24.6 3/4" ID 20 0.4 0.3 0.2 0.2 0.2 0.2 0.1 30 0.8 0.6 0.5 0.5 0.4 0.4 0.3 40 1.5 1.2 0.9 0.8 0.7 0.6 0.5 50 2.4 1.9 1.5 1.3 1.1 1 0.9
Size SCFM 50 PSI 60 PSI 70 PSI 80 PSI 90 PSI 100 PSI 110 PSI 1/2" ID 20 1.8 1.3 1 0.9 0.8 0.7 0.6 30 5 4 3.4 2.8 2.4 2.3 2 40 10.1 8.4 7 6 5.4 4.8 4.3 50 18.1 14.8 12.4 10.8 9.5 8.4 7.6 60 23.4 20 17.4 14.8 13.3 12 70 28.4 25.2 22 19.3 17.6 80 34.6 30.5 27.2 24.6 3/4" ID 20 0.4 0.3 0.2 0.2 0.2 0.2 0.1 30 0.8 0.6 0.5 0.5 0.4 0.4 0.3 40 1.5 1.2 0.9 0.8 0.7 0.6 0.5 50 2.4 1.9 1.5 1.3 1.1 1 0.9
Bore size (Stroke (mm)) 6 8 12 16 20 25 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50, 75, 100, 125, 150 Applicable Auto Switches/Refer to Best Pneumatics No. 3 for further information on auto switches.
SJ3000-50-1A-ll SJ3000-50-1AS-ll SJ3000-50-1AR-ll X, PE port: Metric size 4 Inch size 5/32" Internal pilot (Metric size) C6: With 6 one-touch fitting (straight) C8: With 8 one-touch fitting (straight) L6: With 6 one-touch fitting (elbow upward entry) L8: With 8 one-touch fitting (elbow upward entry) B6: With 6 one-touch fitting (elbow downward entry) B8: With 8 one-touch fitting (elbow downward
Detection nozzle: 1.0 Detection side piping: 6 x 4 tubing Detection nozzle: 1.5 Detection side piping: 6 x 4 tubing Detection nozzle: 2.0 Detection side piping: 6 x 4 tubing 70 70 70 60 60 60 Supply pressure Supply pressure Not detectable 50 50 50 0.1MPa Hysteresis (m) Hysteresis (m) Hysteresis (m) 0.1MPa 40 40 40 Supply pressure 30 30 30 0.1MPa 20 20 20 0.15MPa 0.15MPa 0.15MPa 10 10 10 0.2MPa
-XC6 -XC8 -XC9 -XC10 -XC11 Adjustable stroke cylinder/Adjustable extension type Air-hydro type (mm) Adjustable stroke cylinder/Adjustable retraction type Bore size 20, 25 32, 40 50, 63, 80, 100 Standard stroke Dual stroke cylinder/Double rod 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Dual stroke cylinder
50 PF2MC7202 30 30 42 48 58 -99No.PF-OMZ0002-A Lead wire with M8 connector (ZS-40-A) M12-M8 conversion lead wire (ZS-40-M12M8-A) -100No.PF-OMZ0002-A Revision history A: Contents revised in several places.
Bore size (mm) Bolt Hexagon wrench size Tightening torque (Nm) 32, 40 MB-32-48-C1247 4 5.1 50, 63 MB-50-48-C1249 5 11 80, 100 Foot MB-80-48AC1251 6 25 Other MB-80-48BC1251 5) When replacing the support brackets, the tie-rod nuts on the cylinder body will be loosened.
55 75 F 17 26 41 52 G 40 39 63 68 H 87 91 129 142 J XLAQ-16 XLAQ-25 XLAQ-40 XLAQ-50 40 50 65 70 Note) The heater (Option) is not available with XLAQ-16. 471 Aluminum One-touch Connection and Release High Vacuum Angle Valve 2-step Control, Single Acting/Bellows Seal, O-ring Seal XLDQ Series How to Order XLDQ M9N A 40 q w e r t y w Actuator port direction q Flange size Rear flange surface
Effective area is larger than the former model. 6, 10, 16, 20 AS12l1F-M5 AS13l1F-M5 M5 X 0.8 6, 10, 16, 20 AS12l1F-U10/32 AS13l1F-U10/32 10-32UNF 20, 25, 32 AS22l1F-01 AS23l1F-01 R(PT)1/8 Tube swivels 360 20, 25, 32, 40 AS22l1F-02 AS23l1F-02 R(PT)1/4 40, 50, 63 AS32l1F-02 AS33l1F-02 R(PT)1/4 Universal style permits 360 piping swivel. 40, 50, 63 AS32l1F-03 AS33l1F-03 R(PT)3/8 63, 80, 100
50 5 0 10 15 20 25 Discharge rate (L/min) Discharge rate (L/min) PAF3410 Air Consumption PAF5410 Air Consumption 200 SUP = 0.5 MPa 300 SUP = 0.5 MPa Air consumption (L/min [ANR]) Air consumption (L/min [ANR]) 150 SUP = 0.4 MPa SUP = 0.4 MPa 200 SUP = 0.3 MPa SUP = 0.3 MPa 100 SUP = 0.2 MPa SUP = 0.2 MPa 100 50 0 0 10 15 20 25 5 0 20 30 40 50 10 0 Discharge rate (L/min) Discharge rate (L/
The optimum size for a pressure differential of P 0.4 MPa and a flow of 50 L/min will be the VXZ2 3 A (10 orifice, port size 1/4). 500 400 VXZ2 25 Cv = 12 6 D 300 VXZ2 20 Cv = 9.2 5 C 200 VXZ2 15 Cv = 5.3 4 B Flow rate Q [L/min] 100 VXZ2 Port size 3/8 10 Cv = 2.4 VXZ2 Port size 1/4 10 Cv = 1.9 50 3 A 40 3 A 30 25 20 10 0.01 0.02 0.03 0.04 0.05 0.1 0.2 0.3 0.4 0.5 Pressure differential P
Specifications Lock Specifications Lock position Rear, Front Double acting Action 32 40 50 63 Air Fluid Holding force (max.)
* , *PVC PVC PVC () PVC PVC , -10No.PF-OMN0009CN-F PF3W5 48 () 3 A : 04 20 40 11 21 0.5~4 L/min 2~16 L/min 5~40 L/min 10~100 L/min 50~250 L/min 2 04 20 40 11 21 R 04 20 40 11 21 S 250L/min G L/min(gal/min) / : SI : G : 1[L/min]=0.2642[gal/min] 1[gal/min]=3.785[L/min] 1=9/5+32 L/min 100L/min250L/min Rc N NPT F G IS0228 1 N M8(3m) 04 20 40 11 21 03 3/8 04 1/2 06 3/4 10 1/1 12
MT-S8 8 40 MT-S12 12 Caution Do not apply a load that is 50% or more of the theoretical output.
back direction [mm] 150 100 50 0 50 100 150 150 100 50 0 50 100 150 250 200 150 100 50 0 50 100 150 200 250 0 0 50 50 0.5 s 100 100 0.5 s 150 150 1 s 200 200 2 s 1 s 250 250 5 s 2 s 5 s 300 300 3) With energy saving type de-ionizing cartridge, Supply pressure: 0.3 MPa Installation distance in height from ionizer to workpiece (Charged object location) [mm] Installation distance in height
XL-25 XL-40 XL-50 XL-63 AC90240V Ass'y XLA25-60S-1 XLA25-60S-1 XLA25-60S-2 Ass'y 1 1 1 H4 AC100V 200/40 200/50 400/100 / AC200V 800/40 800/50 800/100 Ass'y XLA25-60S-1 XLA25-60S-2 XLA25-60S-2 XLA25-60S-3 Ass'y 1 1 1 1 H5 AC100V 200/40 400/70 400/80 600/130 / AC200V 800/40 1600/80 1600/80 2400/130 XL-80 XL-100 XL-160 AC90240V Ass'y XLA25-60S-3 XLA25-60S-2 XLA25-60S-2 Ass'y
MXJ4 MXJ4L 4.5 MXJ6 MXJ6L 6 MXJ8 MXJ8L 8 60 500 50 Theoretical output (N) MXQ / MXS 40 MXQ 100 Height (mm) 30 50 20 MXJ 10 MXJ 10 50 5 20 30 150 Stroke (mm) 0 1 10 100 1000 Allowable moment (Nm) Operating pressure: 0.5 MPa when operating direction is OUT.
How to Order Burst pressure drop curve 1.0 TL0604 Metric sizes 20 Burst pressure drop coefficient 0.8 TIL01 20 Inch sizes 0.6 Length Applicable to both metric and inch size Tubing Model 0.4 Symbol 10 20 50 100 Type Length 10 m 20 m 50 m 100 m 0.2 Roll 0 20 40 60 80 100 120 140 160 180 200 220 240 260 Temperature (C) Straight 2 m 2S Length Applicable to inch size only Eluting fluorine ion
Circulating fluid temperature[] Fig. 8-8 Cooling Capacity (HRL100/200/300-A-20) 8.4 Cooling Capacity HRL Series 8-8 HRX-OM-W060 Chapter 8 Documents 8.5 Pump Capacity 8.5.1 HRL100A20 CH1 0.6 60 0.5 50 Circulating fluid outlet Lifting head [m] Pressure [MPa] 0.4 40 0.3 30 Usable flow rate range 0.2 20 Circulating fluid return 0.1 10 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 Circulating