HOW TO ORDER NVFil 250 -N02 02 S v"lrrs..i"" Tt L Rolter Material (01, 02, O6) : Acetal (Standard) NVFM 250(1) Cy1.0 NVZM 450(1) Cy0.55 S : Steel Pilot Supply 0 : Internal Pilot From "P" Port 1 = External Pilot Supply (Special Order Only) 00 : lhlve Body Only 0l = StandardCam Lever 02 = Cam Lever-One Way 05 = Plunger 06 = Roller Plunger, Inline 08 = Toggle Lever 30 = Push Button-Mushroom'
kbps 0 1 1 2 500 kbps 0 2 2 3 : : : : PGM 6 2 62 9 6 3 63 6 4 : : PGM 9 DeviceNetPGMHW/SW ON -21No.EX-OMN0029CN-D V_SEL SI () Settings1 SI 1 2 OFF OFF 32 4 byte() OFF ON 24 3 byte ON OFF 16 2 byte ON ON 8 1 byte Baud Rate EX600 Settings1 3 4 OFF OFF 1 Mbps() OFF ON 500 kbps ON OFF 250 kbps ON ON 125 kbps 1 Mbps() -22No.EX-OMN0029CN-D Settings2 1 2 OFF OFF 0 () 0 byte OFF ON
(Removal procedure and ) Applicable message I/O message size Input: Max. 8 byte, Output: Max. 8 byte (Changeable by switch settings) 1 2 Baud rate 125 kbps 250 kbps 500 kbps 500 m or less Thick cable 250 m or less 100 m or less Max. length of Network 3 4 Thin cable 100 m or less 156 m or less 78 m or less 39 m or less Total extended cable length Note: Max. extended cable length is 6 m. 11
, 350, 400, 450, 500, 600, 700, 800 12-REA40 12-REA50 50 1300 Non-lube 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 63 12-REA63 Note 1) Stroke exceeding the standard stroke but below the maximum manufacturable stroke is available as special orders.
Turn power off and then on again. 1.6 Over current 500 ms 500 ms 0 1.0 5.0 1.3 1.2 Input signal Voltage [V] Flashing: Two ashing cycles of 250 ms at two-second intervals Error automatically resets when the supply ow rate is recovered (LED goes off). Insufcient supply ow rate Flow rate control Position control (Fully closed) 250 ms 250 ms 2000 ms 1 A
These default values can be changed in the Offset FB Overall Accuracy +/5% (0.5V DC) Input Impedance 150 kOhm or higher Input Voltage 0 10V DC Conversion Speed 10 ms Resolution 10/250 mv Analog Input Range 0 250 ECC-PNAL-20M*-D 8 Channels: I01 I08 ECC-PNAL-10M*-D 6 Channels: I01 I06 Description Analog Input Specication 7 2.4 Output Specication PneuAlpha Hardware Specification 2 Table 2.7
Note) If the set pressure is 250 kPa and the output pressure on the pressure sensor is 245 kPa, the deviation is 250 245 = 5 kPa. In order to correct the deviation, the controller increases the output signal until the pressure on the pressure sensor converges at 250 kPa. Step 1 Step 2 Step 3 Step 4 . . . . . . . . . . . . .
N.O. 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz Note) N.O. valve operates properly only when appropriate pressure is applied to the pilot.
110 110 130 130 130 170 170 195 195 195 245 245 245 19 19 19 19 19 19 20 20 10 10 10 10 10 10 20 20 63 63 63 63 63 63 76 76 14 14 14 17 17 17 17 17 90 90 90 126 126 126 197 197 30 30 30 60 60 80 120 120 177 177 177 227 227 227 285 285 110 110 110 130 130 130 150 150 120 120 120 140 140 140 170 170 30 310 380 450 520 590 45 385 485 585 685 560 650 750 850 Fixed Connection part dimensions
DataA: Inlet Air Temperature F 80 90 100 110 120 130 140 149 C 27 32 37.8 43 49 54 60 65 IDFB60/IDFB70 1.33 1.21 1.00 0.78 0.61 0.48 0.38 0.28 IDFB80/IDFB90 1.38 1.38 1.00 0.83 0.63 0.50 0.45 0.37 DataB: Ambient Temperature F 80 90 100 110 113 C 27 32 37.8 43 45 IDFB60/IDFB70 1.16 1.11 1.00 0.78 0.71 IDFB80/IDFB90 1.40 1.22 1.00 0.88 0.83 DataC: Inlet Air Pressure psi 50 60 70 80 90 100 120
Grommet, Grommet terminal, Conduit terminal DIN terminal, L plug connector, M plug connector Electrical entry VT 100, 200, 12, 24, 48, 110, 220, 240 AC (50/60 Hz) DC Coil rated voltage (V) VP 24, 6, 12, 48, 100, 110 Allowable voltage fluctuation 15 to 10% Inrush VG 5.6 VA/50 Hz, 5.0 VA/60 Hz 3.4 VA/50 Hz, 2.3 VA/60 Hz 1.8 W 2 W Note) Apparent power (AC) Holding W/o indicator light W/ indicator
Seal Metal seal Rubber seal Coil voltage 0 1 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Function 1 2 3 Stations U side Standard type (1 W) Low wattage type (0.5 W) External pilot Nil Y R (1) D side (2) Note 1) Applicable to DC specifications. Note 2) Refer to page 2-5-39 for external pilot specification.
70 75 80 85 90 95 100 105 110 115 140 165 75 80 85 90 95 100 105 110 115 120 145 170 90 95 100 105 110 115 120 125 130 155 180 95 100 105 110 115 120 125 130 135 160 185 100 105 110 115 120 125 130 135 140 165 190 105 110 115 120 125 130 135 140 145 170 195 15D (M) 10D (M) 20D (M) 15D (M) 25D (M) 20D (M) 30D (M) 25D (M) 10 35D (M) 30D (M) 15.5 40D (M) 35D (M) 45D (M) 40D (M) 50D (M) 45D
light Diode (varistor when non-polar types) LED In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
VN Solenoid valve option Nil Standard Rated voltage 1 2 3 4 5 6 7 8 9 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC separately.) LVC Select an option mark in page 17-3-9 by Applicable Fluids Check List for special fluids outside of the standard.
Form w 1 Material e Buffer spec. r Buffer stroke t Vacuum inlet y 4 4 1.6 Connection thread C N S U F GN GS 6 N4 N6 U4 U6 64 38 15 10 95 41 ZP Y 06 08 B J K A8 Width across flats 12 A 43 15 100 46 25 110 56 Width across flats 7 Dimensions Per Vacuum Inlet Model 30 B D E Fitting part min. hole size Vacuum inlet direction q Pad dia.
Therefore, design within the rated water flow range (refer to the model column). 37 37 55 55 75 75 110 110 How to Calculate Outlet Air Temperature Correction Factor by Cooling Water Temperature Air pressure 0.7 MPa Outlet air temperature can be calculated with inlet air temperature, cooling water temperature and amount of air in the following procedure.
5 Pilot valve assembly How to Order Pilot Valve Assembly SCZ2 G 1 1 Rated voltage Series VZ200 1 100 VAC, 50/60 Hz Pilot pressure exhaust Manual override Electrical entry 2 200 VAC, 50/60 Hz 1 Spacer side exhaust (Type 20) 3 110 VAC, 50/60 Hz Nil Push type (Safety style) G H L LN L plug connector With lead wire 600 mm lead wire 300 mm lead wire 4 220 VAC, 50/60 Hz Grommet B Locking type
Mounting bolt Mounting bolt diagram C D D Model C Mounting bolt Model C D Mounting bolt M5 x 55l x 60l x 65l x 70l x 75l M8 x 95l x 100l x 105l x 110l x 115l CHQB63 10D (M) 5D (M) CH QB20 55 60 65 70 75 80 85 90 95 100 70 75 80 85 90 95 100 105 110 115 140 165 75 80 85 90 95 100 105 110 115 120 145 170 90 95 100 105 110 115 120 125 130 155 180 95 100 105 110 115 120 125 130 135 160 185 100
(KPa) -111(KPa) () (H1) (H1) 1.1(MPa)2.2(MPa) 110(KPa) -111(KPa) (H_1) 1.1(MPa)2.2(MPa) 110(KPa) -111(KPa) (H1) (H1) 1.1(MPa)2.2(MPa) 110(KPa) -111(KPa) : OUT1 OUT2 "1""2"() P_1 P_2 -26No.PS-OMM0002CN-F [F 2] OUT2 OUT2 OUT1 , <> [F 2] [F 1] OUT1 (2426 ) [F 3] () <> [F 3] [F 3] -27No.PS-OMM0002CN-F [F 4] / / 0 <> [F 4] -28No.PS-OMM0002CN-F [F 4] / 5ms ooo1 C_5 10 ms