DATA OUT 1 2 3 SET 1 2 SET MONOSASHI-KUN AC100V OUT1 COM OUT2 COM COM OUT3 Series Guide Series CE1 Bore size (mm) Available stroke range Standard stroke (mm) Series CEP1 Standard stroke (mm) Bore size (mm) 12 equiv. 250 400 500 300 175 200 150 125 100 75 50 100 25 75 50 25 12 25 to 150 20 equiv. 20 25 to 300 32 25 to 400 40 25 to 600 50 25 to 600 63 25 to 600 CEU1 CEU5 Output transistor system
For Air Upstream pressure of valve P1 1.0 MPa 1.0 Downstream pressure of valve (P2) MPa Downstream pressure of valve (P2) MPa 0.8 Subsonic Critical pressure 0.9 0.6 0.7 0.8 Sonic 0.4 0.6 0.5 0.4 0.2 0.3 0.2 0.1 0 VX211 VX22 VX23 VX2 4 VX2 5 VX2 60-02 VX2 602 50 100 150 200 250 300 350 3 100 200 300 400 500 600 4.5 200 400 600 800 1,000 1,200 3 2 3 2 3 2 3 2 03 04 6 500 1,000 1,250 8 500
Refer to the Installation / Operation manual for details Table 2.5-3 Monitoring method for contact input Contact input delay timer for reading Monitoring method 0 sec Continuous monitoring 1 to 300 sec Monitor only during operation 2.5 Contact input signal HRR Series 2-14 HRX-OM-W004 Chapter 2 Contact input/output communication Operation start Operation stops due to the alarm.
Conversion cable P5062-5 (Cable length: 300 mm) 300 * To connect the teaching box (LEC-T1-3mGm) or controller setting kit (LEC-W2) to the controller, a conversion cable is required. 7 JXCE1/91/P1/D1 Series Precautions Related to Differences in Controller Versions As the controller version of the JXC series differs, the internal parameters are not compatible.
Influence Unit Item Standard value Corrosion Scale Operating Environment/Storage Environment Warning generation p p p p p p pH (at 77F (25C) 6.0 to 8.0 100to 300 Electrical conductivity (77F (25C) [S/cm] 1. Avoid using the Thermoelectric Bath in an environment where it could be splashed by fluids (including mist) such as water, salt wa-ter, oil, chemicals, or solvents. 2.
. ~ + ~~ IZ/ A Modular Type Regulator with Built-in Pressure Gauge Series AR200 1 250 1 300 1400 1 Specifications Model AR2001 I AR2501 I AR3001 I AR4001 1/4,3/8 1 1/4,3/8 I 1/4,3/8,1/2 Port size 1/8,1/4 -' Proof pressure 1.5MPa 115.3kgflcm21 Max. operating pressure 1.0MPa 1 10.2kgf/cm21 Set pressure range 0.05~0.85MPa 10.51 ~8.7kgf/cm2J Ambient and fluid temperature -5~60 'C (Prevent
25 to 800 77 93 M8 x 1 M27 x 2 46 33 20 19 36 36 30 58 50 31 115 30 18 32 1/2 66 29 32 13 74 80 25 to 800 96 93 M33 x 2 57 32 M10 x 1.25 20 13 45 45 41 75 60 42 133 30 17 32 1/2 74 29 41 17 80 113 +0.052 0 100 25 to 1000 115 M42 x 2 58 42 M14 x 1.5 28 16 56 56 50 90 72 38 146 40 22 39 3/4 86 34 52 19 97 Bore size (mm) V Y ZZ W SS 40 6.5 11.5 58 190 151 50 8 11.5 65 203 158 63 12 17.5 69 250
, 300, 1/4 Vacuum suction type 350, 400, 450, 500 3/8 Note) Consult SMC for long stroke.
Plug Insertion Force in Pressurized Condition Insertion Force of Series KK 350 300 250 Insertion force N Series KK6 200 Series KK4 150 100 Series KK3 Series KK2 50 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Charging pressure MPa Insertion Force of Series KKA 500 Series KKA8 Series KKA9 400 Series KKA7 Insertion force N 300 Series KKA6 Series KKA4 200 100 Series KKA3 0 0 0.1 0.2 0.3 0.4 0.5
Cushion adjustment (Relief adjustment) man-hours are the same as the adjustment (cushion needle adjustment) for general purpose cylinders. 350 High power cylinder 300 General purpose cylinder (SMC Series CG1) Buffer capacity [kgf cm] Quality of cushioning (RHCF40-500, Load weight 5kg, Supply pressure 0.5MPa, Horizontal operation) 250 500 3000mm/s 1000mm/s 2000mm/s 200 500mm/s 400 150 Deflection
70 30 40 50 60 30 60 70 50 40 20 Point of application L (mm) Point of application L (mm) RS H A RZQ MIW20 MIS20 MIW25 MIS25 MIW32 MIS32 MI W S 200 320 0.7 MPa 500 CEP1 0.7 MPa 280 0.2 MPa 0.3 MPa 0.4 MPa 0.5 MPa 0.6 MPa 0.7 MPa 0.6 MPa 0.6 MPa 160 CE1 0.5 MPa 240 0.5 MPa 400 0.4 MPa 0.4 MPa CE2 0.3 MPa Lateral load F (N) Lateral load F (N) Lateral load F (N) 200 0.3 MPa 120 0.2 MPa ML2B 300
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.1 0.05 0.01 50 100 300 200 (141) 500 Maximum speed (mm/s) 2. Rod end allowable lateral load Make sure that the lateral load that is applied to the rod end will be no more than the values shown in the tables.
Bore sizes: 25, 32 40, 50, 63 mm; Stroke lengths: 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 mm; Maximum stroke length: 1300 mm (25, 32, 40, 50 & 63 bore); Minimum operating pressure: 0.18 MPa (26 psi); Speed: 50 ~ 300 mm/sec.
Bore sizes: 25, 32 40, 50, 63 mm; Stroke lengths: 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 mm; Maximum stroke length: 1300 mm (25, 32, 40, 50 & 63 bore); Minimum operating pressure: 0.18 MPa (26 psi); Speed: 50 ~ 300 mm/sec.
1% F.S. or lessMaximum load impedance: 300 (Power supply voltage 12 V)600 (Power supply voltage 24 V)Minimum load impedance: 50 Non-voltage input (Reed or Solid state), Low level: 0.4 V or less, 5 ms or longer input3 1/2-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 25 ?3C)Lights up when output is turned ON.
1% F.S. or lessMaximum load impedance: 300 (Power supply voltage 12 V)600 (Power supply voltage 24 V)Minimum load impedance: 50 Non-voltage input (Reed or Solid state), Low level: 0.4 V or less, 5 ms or longer input3 1/2-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 25 ?3C)Lights up when output is turned ON.
1% F.S. or lessMaximum load impedance: 300 (Power supply voltage 12 V)600 (Power supply voltage 24 V)Minimum load impedance: 50 Non-voltage input (Reed or Solid state), Low level: 0.4 V or less, 5 ms or longer input3 1/2-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 25 ?3C)Lights up when output is turned ON.
1% F.S. or lessMaximum load impedance: 300 (Power supply voltage 12 V)600 (Power supply voltage 24 V)Minimum load impedance: 50 Non-voltage input (Reed or Solid state), Low level: 0.4 V or less, 5 ms or longer input3 1/2-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 25 ?3C)Lights up when output is turned ON.
Double acting, single rod, non-rotating, direct mount, Bore size *: 20, 25, 32, 40, 50, 63, Standard stroke *: 25, 50, 75, 100, 125, 150, 200, 250, 300, Auto switch capable, Variety of lead wires and prewired connectors, CG1 CYLINDER, NON ROTATING, ROUND BODY CYLINDER, 333, 0.65 lb
. *, various mounting configurations, cushion for noise damping.Air cylinder, double rod, non-lube type, Bore sizes *: 125, 140, 160, 180, 200, 250, 300, Mountings: basic, foot, flange, trunnion, Rod boots and cushions available, Auto switch capable for 125mm~200mm bores, CS1 Cylinder, TIE ROD CYLINDER, 529, 164.54 lb