110 K 38 32 C 70 60 X ZZ NA E D B 72.2 58.2 I 70 60 W 12-REA63 12-REA50 100 86 66 53 30-0.033 69 55 M10 x 1.5 x 16 M8 x 1.25 x 16 188 176 M14 x 1.5 x 11.5 M12 x 1.25 x 7.5 192 180 0 26 25 0 32-0.039 167 Specific Product Precautions Be sure to read before handling. 12-CY1B/3B/1R/3R/REA.
8 22 8 15 80 18 M6 x 1 20 40 36 M26 x 1.5 124 13 10 70 41 41.6 3 16 11 29 10 16 92 23 M6 x 1 26 50 46 M32 x 2 150 13 TF TN Nil P (Piping port) ZZ X W TT Model 12-REA25 12-REA32 12-REA40 50 Rc1/8 30 NPT1/8 137 G1/8 17 50 Rc1/8 40 NPT1/8 156 G1/8 19 60 Rc1/4 40 NPT1/4 182 G1/4 22 12-REA50/63 0 L0.2 33 B 2 x 4 x V Effective thread depth 16 2 x P (Piping port) 14 14 8 (R) D X Q Q 14.5 22 I 2
(For accumulated decrement) [ 150] 150 L/min (PF3A703H) [ H] Setting of Hysteresis [ 300] 300 L/min (PF3A706H) Caution Press the button once to reduce the value by one digit, press and hold to continuously reduce. [ 600] 600 L/min (PF3A712H) : If the error cannot be reset after the above measures are taken, then please contact SMC.
Only air, N2, are applicable. [6000] 6000 L/min (PF3A712H) [F 1] [ 150] 150 L/min (PF3A703H) The accumulated flow has exceeded the accumulated flow range. (For accumulated increment) [H_1 ] Setting of Hysteresis [ 300] 300 L/min (PF3A706H) Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system.
), ANATEL (Brazil), NOM (Mexico), ETA (India), IC (Canada), NBTC (Thailand), SRRC (China), NCC (Taiwan), KC (Korea), ACMA (Australia/New Zealand), Radio Law certificate IMDA (Singapore), SIRIM (Malaysia), ENACOM (Argentine), ICASA (South Africa), NCT (Philippines), FAC (Russia), CoC (Ukraine), ANRT (Morocco) Power supply voltage 24 VDC 10% For control and input (US1) Current consumption 150
Piston speed (3) 150 cm3/min or less 200 cm3/min or less 300 cm3/min or less Supply pressure 0.1 MPa Total allowable leakage MQQ M 800 cm3/min or less 1000 cm3/min or less 1200 cm3/min or less Supply pressure 0.3 MPa 1500 cm3/min or less 2000 cm3/min or less 3000 cm3/min or less Supply pressure 0.5 MPa RHC Note 1) Use clean, dry air with no freezing.
Options J: With drain guide T: With element service indicator Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5 6 6 7 7 9 9 9 11 N 35 O 54 66 66 80 80 88 88 102 136 P 70 84 84 100 100 110
Micromist separator AMD900, 1000, 901 Model Connect (Flange) 2B 2B/3B/4B 400 A 280 B 6B C 550 D 150 E 270 F 823 G 3 H 797 J 620 AMF801 AMF901 445 12B 570 300 520 1093 3 867 AMF800/900/1000 Mounting Caution q Verify the direction of the flow of the compressed air and the "e" mark that indicates the inlet of the product before connecting.
Inch size 1/4" 1/8" 5/32" Flow rate (l/min(ANR)) 170 100 120 150 IN OUT Effective area (mm2) 2.6 1.5 1.8 2.3 IN P1 Note) Flow rate is the value measured under a pressure of 0.5 MPa and a temperature of 20C.
Standard Strokes Symbol Rubber bumper Bore size [mm] Standard stroke [mm] 12 (10 x 2) 16 (12 x 2) 10, 20, 30, 50, 100 20 (16 x 2) 25 (20 x 2) 20, 30, 50, 100, 150 32 (25 x 2) 40 (32 x 2) 50 (40 x 2) 63 (45 x 2) 80 (56 x 2) 100 (71 x 2) 25, 50, 100, 150, 200 Intermediate strokes are available as a special order. Refer to pages 10 and 11 for cylinders with auto switches.
50 Bore) Screw & Nut Kit included with cylinder Switch # Switch # Actuator Mounting Auto Switch Mounting Hardware (brackets,bands, screws & nuts) is identical to our CDS1 Tie Rod Mounting BT-12 (125/140 Bore) BT-16 (160 Bore) BT-18 (180 Bore) BT-20 (200 Bore) our new part # C95D Tie Rod Mounting BT-03 (32/40 Bore) BT-05 (50/63 Bore) BT-06 (80/100 Bore) -F5PSDPC NCDA1 Tie Rod Mounting NBT-150
Hz: 9.8 m/s2 Acceleration Sweep Count for X,Y,Z: 10 times (80 minutes in each direction) Conforms to IEC 68-2-6; 10-57 Hz: 0.15 mm Constant Amplitude 57-150 Hz: 19.6 m/s2 Acceleration Sweep Count for X,Y,Z: 10 times (80 minutes in each direction) 9 PneuAlpha Hardware Specification 2 Table 2.8:Environmental and Electrical Specications Insulation Resistance 7 Mohm at 500V DC per EN60730-1
N212 VaY' 3 Port lVFl 10 seies Direct Solenoid Operated o Cv 0.055 (0-100 PSI); 0.05 (0 -150 PSI) Port Size 118" NPTF (Standard) High Speed Response Time 8mSec.
Supplv Pressure 220 PSIG (15 Kqflcmz) Operating Pressure 22-150 PS|G (1.5-9.9 Kqf/cm2) 15-150 PS|G (1-9.9 Kqf/cm2) Ooeratino TemDerature 40-140'F (5-60'C) Bodv Aluminum Die Cast Spool & Sleeve 440F Stainless Steel, passivated & heat treated to 58-63 Rockwell C. Sleeve O-Rinqs Buna N Soacer Delrin Shock Pad Urethane Rubber Max. Cycle Rate 300 cPM Weight (Valve Body Only) oz.
Refer to catalog N366 Series Variations @ Boq1" l N m ) L lg) 10 16 20 25 32 40 50 MHY2NOD 10 0 . 1 6 71 70 MHY2N60 1 6 0.54 84 150 MHY2-MD 20 1 . 1 0 106 3m MHY2.25D 2.24 560 MHw2 Rack Style Unique seal design Grippng force when allows shorter total length construction and constant opening and closing fingers.
Not required Unrestricted 150/30 Note 1) Be certain that pressure within operating pressure range be supplied to supply port, because return pressure is introduced from supply port {1(P)} for activation. Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester.
Standard Stroke Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.
Membrane Air Dryers 361 405 428 468 548 618 83 187 53 113 212 54 1/4 73 140 40 Port size L B A Port size L A B C 70 91 3/8 1/2 3/8 IN Port size: 1/4 OUT Port size: 1/4 IDG30, 30L IDG50, 50L IDG60 IDG75, 100 IDG60L, 60S IDG75L, 75S IDG100L, 100S Model Model (67) (46) (26) IDG3, 5 IDG10 IDG20 Width across flats 17 Width across flats 14 Width across flats 14 Purge air outlet for dehumidification
page 60.) 25 or less Max. operating frequency (Hz) 5 Non-locking push type, push-turn locking slotted type, push-turn locking lever type Manual override (Manual operation) Individual exhaust for the pilot valve, common exhaust for the pilot and main valve Pilot exhaust method Body ported Lubrication Mounting orientation Shock/Vibration resistance (m/s2) Note 2) Not required Unrestricted 150
Station n L1 L2 Station 2 78 50 Station 20 438 410 3 98 70 4 118 90 5 138 110 6 158 130 7 178 150 8 198 170 9 218 190 10 238 210 11 258 230 12 278 250 13 298 270 14 318 290 15 338 310 16 358 330 17 378 350 18 398 370 19 418 390 65 Series SYJ7000 Type 42: Side Ported/SS5YJ7-42Stations C6,N7 C8,N9 [ ]: AC Grommet (G) 122 [126.4] Approx. 300 (Lead wire length) Manual override L1 14 L2 4-4.5