It cannot be used if connected in the opposite direction. 4.6-24 Series AME Dimensions: AME150 to AME350 M Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 146 167 167 198 198 I 56 66 66 80 80 J 15 20 17 22 19 K 5 8 8 8 8 L 9 12 12 14 14 N 35 40 40 50 50 O 54 66 66 80 80 P 70 84 84 100 100 Q 26 28 28 34 34 R 4.5 5 5 5 5 S 1.6 2.0 2.0 2.3 2.3 1/8, 1/4, 3/8
Options J: With drain guide M Mounting Dimensions Model Port Size (Nominal size B) A G F E D C B S 1.6 2.0 2.0 2.3 2.3 3.2 3.2 4.5 4.5 R 4.5 5 5 5 5 9 9 10 12 Q 26 28 28 34 34 50 50 60 76 P 70 84 84 100 100 110 110 130 180 O 54 66 66 80 80 88 88 102 136 N 35 40 40 50 50 55 55 65 85 L 9 12 12 14 14 14 14 16 20 K 5 8 8 8 8 10 10 10 15 J 15 20 17 22 19 25 21 30 40 I 56 66 66 80 80 90 90 100
12 93.4 101.4 19 143.8 151.8 2 21.4 29.4 3 28.6 36.6 4 35.8 43.8 5 43 51 6 50.2 58.2 7 57.4 65.4 8 64.6 72.6 9 71.8 79.8 10 79 87 11 86.2 94.2 13 100.6 108.6 14 107.8 115.8 15 115 123 16 122.2 130.2 17 129.4 137.4 18 136.6 144.6 20 151 159 L1 L2 4-11-13 14 Series S070 Manifold Options Blanking plate assembly (for SS073A) 7 SS070A-10A (for separable base) This assembly is mounted on a manifold
Clamping block Fulcrum L Bore size: 50 Bore size: 63 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 50 100 150 200 250 300 10 9 8 7 6 5 4 3 2 1 0 50 100 150 200 250 300 Allowable load mass [kg] Allowable load mass [kg] 15 15 105 30 30, 45, 60 105 90 120 120 75 90 45, 60 75 Arm opening angle: 135 Arm opening angle: 135 Distance to the center of gravity [mm] Distance to the center of gravity [mm] Bore
measured with pressure at 0.5MPa and temperature at 20C. 14
As the flow rate when Kv = 1 is calculated as the formula: Q0 = 15 x 1/1.5 = 10 [L/min], read off P when Q0 is 10 [L/min] in Graph (2). The reading is 0.036 [MPa]. Example 2) Obtain the saturated steam flow rate when P1 = 0.8 [MPa] and P = 0.008 [MPa] with a solenoid valve with a Kv = 0.05 [m3/h]. Read off Q0 when P1 is 0.8 and P is 0.008 in Graph (2), the reading is 20 kg/h.
Model IDF1E IDF2E IDF3E IDF4E 0.26 Air discharge without drainage Operating air pressure 50 Hz 0.085 0.12 0.18 Air flow capacity (m3/min (ANR)) 6 l (ANR) per cycle 0.3 MPa 60 Hz 0.1 0.14 0.21 0.29 10 l (ANR) per cycle 0.5 MPa Model IDF6E IDF8E IDF11E 0.65 14 l (ANR) per cycle 0.7 MPa 50 Hz 0.32 0.5 Operation cycle: 1 cycle per min. Operation time: 2 sec./min.
Max. flow capacity L/min (ANR) 3F 4 30 4G 6 65 5H 8 130 7J 10 200 Plug-in type Bracket SFE-BR 3 Symbol Applicable model 3 SFE3l 4 SFE4l 5 SFE5l 7 SFE7l One-touch fitting type Specifications Model SFE11 SFE3 SFE4 SFE5 SFE7 Fluid Note 1) Air Maximum flow capacity Note 2) Up to 3 L/min (ANR) Up to 30 L/min (ANR) Up to 65 L/min (ANR) Up to 130 L/min (ANR) Up to 200 L/min (ANR) Filtration rating
With L-bracket B1 With pivoting bracket B2 With DIN rail mounting bracket B3 Output specification Refer to page 450.
AT Ambient temperature 0.98 B 75 psi (0.53 MPa) Inlet air pressure 0.95 C IDF IDU 14 SCFM Air consumption Note) Values obtained from the table below. IDFA 2 Calculate the corrected air flow capacity. IDFB IDFB Corrected air flow capacity = 14 SCFM (0.82 x 0.98 x 0.95) = 18 SCFM Obtain the corrected air flow capacity from the following formula.
Model Controller Allowable Moment (Nm) Allowable static moment Allowable dynamic moment LG1H20 Model Mounting orientation Load movement direction Pitching Rolling Yawing 71 79 75 Horizontal/Lateral Horizontal/Lateral Lateral Horizontal a = 1000 a 4000 a = 2000 L1 (mm) Pitching Mep m : Transfer load (kg) a : Work piece acceleration (mm/s) Me: Dynamic moment L : Overhang to work piece center
When the motor mounting position is right side parallel (LEFS*R) or left side parallel (LEFS*L), the rotation direction selection is 0(+: Counter motors side).
Petroleum, Water-glycol, Emulsion: NBR; Phosphoric ester: FKM, EPDM Model/Rated Flow Rate Connection Model Port size Rated flow rate Companion flange, Female threaded companion flange, L-block companion flange, L-block female threaded companion flange, S-block companion flange, S-block female threaded companion flange (L/min) FHG9A-M-04 FHG9A-M-06 FHG9A-M-08 FHG9B-M-10 FHG9B-M-12 FHG9B-M-
4 16 14+ST 4.5 4.5 (Hexagon socket set screw) M8 x 1.25 x 8 L (Bolt holder) 1 40 45 45 3 3 330.2 330.2 330.2 42 20 8 8 6.5 counterbore depth 5.5 (Same on the opposite side) 3.4 through 2 x M3 x 0.5 through 3 3 6.5 45 45 M4 x 0.7 x 14.5 L (Hexagon bolt) and M4 x 0.7 (Hexagon nut) M3 x 0.5 x 10 L (Hexagon socket head cap screw) 2 x M4 x 0.7 through Steel ball Steel ball (14+ST) (16) 4 2 x M3
1 Filter Bowl assembly Lubricator AF11-2 AF11-3 AL12-2 AL12-3 14-3-11 2 Series AU Flow Characteristics Inlet pressure: 1.0 MPa Outlet pressure (MPa) Outlet pressure (MPa) Outlet pressure (MPa) Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Pressure Characteristics Inlet pressure: 0.7 MPa, Outlet pressure: 0.2 MPa, Flow rate: 20 l/min (ANR) Outlet pressure (MPa) Outlet
Fittings & Tubing Air Cylinders Rotary Actuators J 12 Maximum 14.5 (With stroke adjuster at retraction end) I 7.5 8 15 15 14 14 12 6.5 6.5 Vacuum suction port Rc, G, NPT1/8 12 25 6.5 K NA x M6 x 1 thread depth 6.5 25 KA Stroke adjuster at extension end Stroke adjuster at retraction end 6 18 46.5 (With stroke adjuster at extension end) N x M5 x 0.8 thread depth 10 (Insert) 6 x M5 x 0.8 thread
Operate under the following conditions to avoid malfunction. < N.O. type > Operating pressure: 15 psi [0.1 MPa] or more Operate the compressor at 3.7 kW (14 scfm [400 L/min (ANR)]) or more.
Display for Wireless Base 14 3.2.1. Information tab 14 3.2.2. Input/Output monitor tab 16 3.2.3. Setting tab 20 3.3. Display for Wireless Remote 30 3.3.1. Information tab 30 3.3.2. Input/Output monitor tab 32 3.3.3. Setting tab 36 3.4. Detailed information of units 41 3.4.1. Information tab 41 3.4.2. Details of I/O monitor tab 50 4. Setting Function 57 4.1. Edit TAG 57 4.2.