Bore Size: 8mm, Stroke: 20mm, Adjuster: Metal Stopper, Magnet: w/o Magnet and Rail, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Bore Size: 8mm, Stroke: 20mm, Adjuster: Rubber Stopper, Magnet: w/o Magnet and Rail, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Bore Size: 8mm, Stroke: 10mm, Adjuster: Rubber Stopper, Magnet: w/o Magnet and Rail, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Bore Size: 8mm, Stroke: 10mm, Adjuster: Metal Stopper, Magnet: w/o Magnet and Rail, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Bore Size: 8mm, Stroke: 10mm, Adjuster: -, Magnet: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Types: Gasket, Maintenance part name: Seal kit, Bore size(ø): 8, Compatible air cylinder details: Compact Cylinder, Enhanced Water-Resistance Type, Double Acting, Single Rod, Material: FKM
Type: Table Type, Cylinder Inner Diameter(Ø): 8, Stroke(mm): 10, Max. Load Mass (Horizontal Mounting)(kg): 0.05~0.8, Table Size Length L(mm): 21, Table Material: [Aluminum] Aluminum, Guide: [Rolling Guide] Linear guide type, Table Size Width W(mm): 22, Table Size Height H(mm): 18, Table Parallelism(µm): 20, Environment: General Purpose, Maximum Load(kg): 0.75, Port Screw Type: M screw, Adjuster
Type: Table Type, Cylinder Inner Diameter(Ø): 8, Stroke(mm): 20, Max. Load Mass (Horizontal Mounting)(kg): 0.05~0.8, Table Size Length L(mm): 41, Table Material: [Aluminum] Aluminum, Guide: [Rolling Guide] Linear guide type, Table Size Width W(mm): 22, Table Size Height H(mm): 18, Table Parallelism(µm): 20, Environment: General Purpose, Maximum Load(kg): 0.75, Port Screw Type: M screw, Adjuster
.: 4, 6, 8, 10, 12, Applicable fittings include: KQ, KJ, KF, KFG, and M/MS, Tubing colors include: black, white, red, blue, yellow green, Maximum operating pressure: 20C = 0.8 MPa and 60C = 0.4 MPa, TUBING, WEAR RESISTANT, CONNECTORS, TUZ WEAR RESISTANT TUBING, FX, TUZ 6MM, .86112 lb, ModelTubing O.D. (mm)Tubing I.D. (mm)--TUZ060464--
Standard condition (ANR) and normal condition (NOR) are defined as follows: Standard condition (ANR): 101.3kPa, 20C, 65%RH. Normal condition (NOR): 101.3kPa, 0C
Standard condition and normal condition are defined as follows: Standard condition: Displayed flow rate which is converted to volume at 20C, 101.3 kPa (absolute pressure). Normal condition: Displayed flow rate which is converted to volume at 0C, 101.3 kPa (absolute pressure).
Standard condition and normal condition are defined as follows: Standard condition: Displayed flow rate which is converted to volume at 20C, 101.3 kPa (absolute pressure). Normal condition: Displayed flow rate which is converted to volume at 0C, 101.3 kPa (absolute pressure).
Standard condition and normal condition are defined as follows: Standard condition: Displayed flow rate which is converted to volume at 20C, 101.3 kPa (absolute pressure). Normal condition: Displayed flow rate which is converted to volume at 0C, 101.3 kPa (absolute pressure).
Standard condition and normal condition are defined as follows: Standard condition: Displayed flow rate which is converted to volume at 20C, 101.3 kPa (absolute pressure). Normal condition: Displayed flow rate which is converted to volume at 0C, 101.3 kPa (absolute pressure).
SUS316L Stainless Steel Fitting Specifications Applicable tubing Nylon/Fluoro tubing Fluid Water/Chemical base paint, Ink, Cleaning solvent (Water, Butyl acetate), Air Max. operating pressure (at 20C) (MPa) 1.0 (C) Ambient and fluid temperature 0 to 60 Weight VCC12 (2 port) 37 g Valve VCC13 (3 port) 48 g For 2 port 29 g Blanking plug assembly For 3 port 45 g For 2 port (2 stations, one-piece
W (due to an increase in the heat generation of the pump) Note 1) -MT: Applicable to deionized water piping + High pressure pump Note 2) The capacity at the thermo-chiller outlet when the circulating fluid temperature is 20C. Note 3) Required minimum flow rate for cooling capacity or maintaining the temperature stability. Note 4) Cooling capacity will decrease as pump power increases.
W (due to an increase in the heat generation of the pump) Note 1) -MT: Applicable to deionized water piping + High pressure pump Note 2) The capacity at the thermo-chiller outlet when the circulating fluid temperature is 20C. Note 3) Required minimum flow rate for cooling capacity or maintaining the temperature stability. Note 4) Cooling capacity will decrease as pump power increases.
Installation environment and power supply are within specification range and stable. 6 The capacity at the thermo-chiller outlet when the circulating fluid temp. is 20C. 7 Fluid flow to maintain the cooling capacity and the temperature stability.
Installation environment and power supply are within specification range and stable. 6 The capacity at the thermo-chiller outlet when the circulating fluid temp. is 20C. 7 Fluid flow to maintain the cooling capacity and the temperature stability.
Heater operation, PID control Refrigerant type/Refrigerant charge R134a/0.14kg R134a/0.26kg Niose level (reference value) Note 7) 52dB (A) 55dB (A) Weight 26kg 37kg Applicable drain tube O.D. 10mm Coating colour Body panels:White 1 Base:Gray 2 IP Class IP2X Overvoltage Category Category / IEC60664-1 Pollution Degree Degree 2 Applicable directive CE Marking Note 1: ANR refers to conditions of 20C