SMC Corporation of America
Elite Part Number Search
Search Results "MXP10-20C-M9P"

slotted style Max. operating frequency (Hz) VP Manual override Individual pilot exhaust style, Common Exhaust (pilot and main valve) style Pilot exhaust Not required Lubrication Base mounted Free Mounting position VQ Impact/Vibration resistance (m/s2) (2) 150/30 JIS Symbol Dust proof Protection structure VQZ Note 1) According to dynamic performance test JIS B8374-1981 (Coil temperature 20C

At 0.5 MPa, temperature 20C 1690 910 Elbow type Check valve Series AK Large valve capacity Low cracking pressure/0.02 MPa Port size Rc Effective area (mm2) Model 1 8 1 4 27.5 (Rc ) 95 (Rc ) 230 (Rc 1) AK2000 1 4 3 8 1 2 1 2 , 1 4 AK4000 AK6000 , , 3 4 , 1 Series AK 13-14-15 15 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200

Port Solenoid Valve 3 Port Solenoid Valve Power Consumption (with power saving circuit) Temperature rise: 1C (with power saving circuit) V100 Specifications V100 Specifications V100 Specifications V100 Specifications Type With power saving circuit Standard Valves of specific power consumption can be manufactured to suit the f f f p f p p Power Consumption 0.1W 0.35W Temperature rise 1.0C 20C

The valve can be used at ambient temperatures as low as 20C, but take measures to prevent freezing or solidification of impurities, etc. 2. When used in cold areas, adopt freeze prevention measures such as draining the water from pipelines. If warmed with a heater, etc., avoid the coil unit.

The valve can be used at ambient temperatures as low as 20C, but take measures to prevent freezing or solidification of impurities, etc. 2. When used in cold areas, adopt freeze prevention measures such as draining the water from pipelines. If warmed with a heater, etc., avoid the coil unit.

The product can be used at an ambient temperature as low as 20C, but take measures to prevent the solidification or freezing of impurities, etc. 2. When using for water, etc. in a cold area, devise a means to prevent freezing, such as draining the water from pipelines after stopping supply and exhaust water for a pump or other device.

How to Find the Flow Rate (at air temperature of 20C) Subsonic flow when P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P(P2 + 0.1013) Sonic flow when P1 + 0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) Q: Air flow rate [l/min (ANR)] S: Effective area (mm) P: Differential pressure (P1-P2) [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Correction for different air temperatures

(coil temperature 20C, at rated voltage, without surge voltage suppressor) Note 2) Impact resistance: No malfunction when tested with a drop tester in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states.

Standard condition: Flow rate converted to a volume at 20C, 101.3 kPa (absolute pressure), and 65% RH Normal condition: Flow rate converted to a volume at 0C, 101.3 kPa (absolute pressure), and 0% RH Reversible display mode When the switch is used upside down, the orientation of the display can be rotated to make it easier to read by using the reversible display function.

Standard condition: Flow rate converted to a volume at 20C and 101.3 kPa (absolute pressure) Normal condition: Flow rate converted to a volume at 0C and 101.3 kPa (absolute pressure) Response time The response time can be selected to suit the application.

Standard condition: Flow rate converted to a volume at 20C and 1 atm (atmosphere) Normal condition: Flow rate converted to a volume at 0C and 1 atm (atmosphere) * Also, the increase or decrease of the flow and temperature will not change the on/off status of the output while the forced output function is activated.

(Coil temperature: 20C, at rated voltage) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.

Voltage for 20C-114 POTTED (Type P)Class F rated at 105IEEE* and 110 C. Continuous & 125 C. IntermittentU.L.** Coast Rating*** 125 Continuous. The unit is water proof. *IEEE*The temperatures listed are the limiting temperature definitions by this organization for insulation material categories. Therefore, a 2C-115 coil should be used with a field Voltage of 130 volts 60 cycles.

SUS316L Stainless Steel Fitting Specifications Applicable tubing Nylon/Fluoro tubing Fluid Water/Chemical base paint, Ink, Cleaning solvent (Water, Butyl acetate), Air Max. operating pressure (at 20C) (MPa) 1.0 (C) Ambient and fluid temperature 0 to 60 Weight VCC12 (2 port) 37 g Valve VCC13 (3 port) 48 g For 2 port 29 g Blanking plug assembly For 3 port 45 g For 2 port (2 stations, one-piece

(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.

(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.

(Coil temperature: 20C, at rated voltage, without surge suppressor.) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.

ASD330F CM2 VZ500 TU0604 1 m AN11001 25 Cylinder size 32 Values at 0.5 MPa and 20C. Cylinder extension speed: 100 mm/s Meter-out needle fully open 100 mm/s Return speed Solenoid valve (Reference) Recommended circuit for high return speed When low extension speed and high return speed are desired, the following circuit using 3-port is recommended.

ASS ASR ASQ Flow Rate and Effective Area KE Model ASP330F ASP430F ASP530F ASP630F TMH 8 8 10 10 12 Metric size 6, 8 6 1/4" 5/16" 1/4" 5/16" 3/8" 3/8" 1/2" Tubing O.D. 5/16" Inch size JIS Symbol Flow rate (l/min(ANR)) Controlled flow (Free flow) 180 600 750 1100 1190 330 350 Effective area (mm2) 9.3 11.6 17 18.4 2.9 5.2 5.4 Note) Flow rate values are measured at 0.5 MPa and 20C.

ASD330F CM2 VZ500 TU0604 1 m AN11001 25 Cylinder size 32 Values at 0.5 MPa and 20C. Cylinder extension speed: 100 mm/s Meter-out needle fully open 100 mm/s Return speed Solenoid valve (Reference) Recommended circuit for high return speed When low extension speed and high return speed are desired, the following circuit using 3-port is recommended.