Figures in body of chart are suggested minimum rod diameters Exposed Length of Piston Rod (IN) Tons 10 20 40 60 70 80 100 120 1/2 3/4 1 3/4 13/16 1-1/16 1 5/8 7/8 1-1/8 1-1/4 1-3/8 1-1/2 11/16 15/16 1-3/16 1-3/8 1-1/2 2 3/4 1 1-1/4 1-7/16 1-9/16 1-3/16 3 13/16 7/8 1-1/8 1-3/8 1-9/16 1-5/8 1-7/8 4 15/16 1 1-3/16 1-1/2 1-5/8 1-3/4 2 2-1/4 5 1 1-1/8 1-5/16 1-9/16 1-3/4 1-7/8 2-1/8 2-3/8 7-1/
17 9 20.8 10.5 22.8 10.5 8 10 12 When tube insert parts are in line as KQU Union Y, use KRC1.
For operation control of double acting cylinders Two power valves driven by a double acting cylinder allows operation control in 9 positions (3 positions X 3 positions = 9 positions) including slow stopping, acceleration, and deceleration. 3 7 1 5 9 2 4 6 8 Reciprocation Pressure center Closed center Exhaust center Pressure & closed center Exhaust & closed center VEX Universal porting for
XT53440 05 Number of stations 05 06 12 1 station 2 station 8 station 13-9-10
(Tightening torque of M3 screw: 0.5 to 0.7 Nm) 9.
115.1 2 x 5.2 (For mounting) (1/8) 12(PA) port (Mounting groove for M6 thread) (6.4) 12 64 9.4 38.5 63 56.5 (63) 31.5 51.5 31 (60) (74) (43) 3/8, 1/2 1(P), 3(R) port (Distance between ports) 3R 1P NO 40 3 9 M5 x 0.8 (Breathing hole) 42 30.5 100.8 For vacuum/VPA742V-1(-F) 03 04 A B 3/8, 1/2 2(A) port 51.5 2 x 5.2 (For mounting) NC 33 4.5 2A 31 41 (2) (9) 115.1 2 x 5.2 (For mounting) 1/8 12
10 Distance from the workpiece (mm) 0 1 2 3 4 5 6 7 8 9 10 Distance from the workpiece (mm) 0 1 2 3 4 5 6 7 8 9 10 Distance from the workpiece (mm) Size: 80 Size: 100 30 50 0.4 (MPa) 0.4 (MPa) 25 40 0.3 (MPa) 0.3 (MPa) Lifting force (N) Lifting force (N) 20 30 0.2 (MPa) 15 0.2 (MPa) 20 10 0.1 (MPa) 0.1 (MPa) 10 5 0 0 0 1 2 3 4 5 6 7 8 9 10 Distance from the workpiece (mm) 0 1 2 3 4 5 6 7
Form w 1 Material N S U F GN GS 13 06 6 7 3.4 9 ZP B 08 8 9 4.8 10 4 1 N: NBR, S: Silicone rubber, U: Urethane rubber, F: FKM, GN: Conductive NBR, GS: Conductive silicone rubber 2.5 Mounting Bracket Assembly Flat, Ball Joint Type Thin Flat Type with Ribs Bellows Type C A B D Construction p. 115 Mounting Bracket Assembly From p. 121 Single unit 10 to 50 w q ZP 10 B N D Model A B C D E F G
They should be used only to provide support. 9 Mechanically Jointed Rodless Cylinder with Protective Cover Series MY1W Note) The operating range is a guide that includes hysteresis, and therefore, is not guaranteed. The range may vary greatly (as much as 30%) depending on the operating environment.
With float type auto-drain With drain guide Port size A B C D E J K L M N F G H Model P IDG3M/3HM/5M/5HM IDG10M/10HM 157 201 226 150 146 56 87 196 162 158 99 1/8, 1/4 5.5 66.5 35 210 196 15 9 IDG20M/20HM 1/4, 3/8 205 201 66 130 209 13 12 223 209 IDG30M/30HM 162 158 87 6 78 40 20 303 IDG30LM 149 145 56 86 196 9 210 196 5.5 7 5.5 70 95 70 35 50 35 15 22 15 IDG50M/50HM 3/8 177 172 80 87 241
If a moment or torque directly acts on the cylinder, it will lead to reduced service life or damage to machinery. 10-10-8 9 3 Position Cylinder Series RZQ Construction u i @2 r !0 y q w !9 e @1 @4 !3 RE A B @0 REC !2 CX @3 !
D 11.4 11.4 13.4 d 6 6 8 WX 38 48 54 Y 9 11 14 S 4 6 9 Applicable O-ring C9 C9 C11.2 Bore size (mm) 25 32 40 8-12-19 20 Series MY1W Dimensions: 50, 63 4-MM depth M (LL) L 4-B counterbore depth C LD through-hole bottom side J depth K PA YW QW LW PB PG Q+ Stroke Rc 3/8 (Hexagon socket head taper plug) This port is not available for use.
Note 9) The anchor bolt fixing brackets (including 6 M8 bolts) are used for fixing to wooden skids when packaging the thermo-chiller.
Bit 11 Bit 13 Bit 15 4 Bit 0 Bit 2 Bit 4 Bit 6 Bit 8 Bit 10 Bit 12 Bit 14 (EX600-DXE) 1 2 3 4 5 6 7 8 0 2 4 6 8 10 12 14 Bit 0 Bit 2 Bit 4 Bit 6 Bit 8 Bit 10 Bit 12 Bit 14 14 15 16 17 18 19 20 21 1 3 5 7 9 11 13 15 Bit 1 Bit 3 Bit 5 Bit 7 Bit 9 Bit 11 Bit 13 Bit 15 -30No.EX-OMN0035CN-A (EX600-DXF) 0 1 2 3 4 5 6 7 2 Bit 0 Bit 2 Bit 4 Bit 6 Bit 8 Bit 10 Bit 12 Bit 14 3 Bit 1 Bit
{Refer to Table 9} It same for mounting bracket {Refer to Table 11 (P21)} Short Long Fig. 6 Tie rod installation condition 1 3 5 Table 9. Tightening torque Bore size Socket Tightening torque[Nm] 40,50 13 (M8) 7.4 63 17 (M10) 20 80,100 19 (M12) 29 2 4 Tie rod tightening order. 18 3-2-2.
No.MRQB-OM02 / / / / / / / / MRQ MRQ MRQ MRQ 1 1. 1. 1. 1. 11 1-1. 11 1-2. 11 1-3. 11 2. 2. 2. 2. 12 3. 3. 3. 3. 14 3-1. 14 3-2. 14 4. 4. 4. 4. 15 4-1. 15 4-2. 16 4-3. 17 4-4. 17 4-5. 18 4-6. 18 5. 5. 5. 5. 19 5-1. 19 5-2. 21 5-3. 22 6. 6. 6. 6. 24 6-1. 24 6-2. 24 6-3. 25 7. 7. 7. 7. 26 8. 8. 8. 8. 27 9. 9. 9. 9. 28 (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power
0.01mm 700.00mm 7016 00011170h PLC 00 01 11 70 h 2)-700.00mm GW [OUT Data]Address.6 Address.9 Address.7 Address.6 01h 00h 15bit 8bit 7bit 0bit (H) 00 01 11 70 h (H) Address.9 Address.8 70h 11h 15bit 8bit 7bit 0bit (L) 00 01 11 70 h (L) 0.01mm 2 -700.00mm -7016 FFFEEE90h PLC FF FE EE 90 h Address.7 Address.6 FEh FFh 15bit 8bit 7bit 0bit (H) FF FE EE 90 h (H) Address.9 Address.8 90h EEh
9, @0, @1 20 25 32 40 50 63 Set of nos. above !8, !9, @0, @1 MGP20-Z-PS MGP25-Z-PS MGP32-Z-PS MGP40-Z-PS MGP50-Z-PS MGP63-Z-PS Seal kit includes !8 to @1. Order the seal kit, based on each bore size. Since the seal kit does not include a grease pack, order it separately.
31.5 24.5 16.5 3 2.5 4 36 23.4 mounting hole 9 6.5 6.5 47.5 10.5 Foot bracket 15.4 16.7 PE port For the bracket assembly model, refer to page 4-14-19.
4.5 4.5 6.5 3.5 2-M3 x 0.5 (port size) 2-M3 x 0.5 (port size for axial piping type MTS8-P) 9 2-M3 x 0.5 Effective length 5 0.2 5 +0.035 +0.025 4 16 0.2 22 12 M2.5 x 0.45 12 41 + Stroke 53 + Stroke 9 15 0.2 9 4-M3 x 0.5, effective length 5 10 15 0.2 Rod end male threads Width across flats 3.5 +0.035 +0.025 4 M3 x 0.5 3.9 M3 x 0.5 6.4 7 8 4 24 5.5 2.4 Stud bolt part number: MT-S8 Rod end nut