SMC Corporation of America
Elite Part Number Search
Search Results "ISE71-F02-L2"

Type: Pressure Switch, Fluid Type: Air, Maximum Pressure Rating: 1MPa, Minimum Pressure Rating: 0kPa, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Output Method: Switch, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [NPT] NPT, Plumbing Thread Nominal: [1/4] 1/4, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 1.5, Operating Humidity

Nozzle Size: 03 [Nominal Nozzle Size: ø0.3mm; Large Flow, N.C.: 50.8psi (0.34MPa); Latching: 58psi (0.4MPa)], Body: 3 [For Manifold; Port Specification: No Distinction], Exhaust: Port Exhaust, Individual Exhaust, Valve Combination: Supply Valve: N.C.; Release Valve: N.C., Rated Voltage: 24VDC, Electrical Entry: L-Type Plug Connector w/Lead Wire, Manual Override: Non-Locking Push Type, Sensor

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Pressure Range: ISE75G (0 to 2 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)

Pressure Range: ISE79S (0 to 50 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H])

Pressure Range: ISE70G (0 to 1 MPa), Piping: N02 (NPT 1/4), Orifice: T (Orifice shipped with the Product), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)

Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: N (NPN Output), Unit Specification: M (Fixed SI Unit), Stations: 1, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: L2 (w/Control Unit, Supply

Pressure Range: ISE75G (0 to 2 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

The HRZ series thermo-chiller is a high performance device for circulating fluid with a constant temperature. Available in 3 temperature range designs so the best chiller can be selected for operating temperature needs.  No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled

The HRZ series thermo-chiller is a high performance device for circulating fluid with a constant temperature. Available in 3 temperature range designs so the best chiller can be selected for operating temperature needs.  No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled

The HRZ series thermo-chiller is a high performance device for circulating fluid with a constant temperature. Available in 3 temperature range designs so the best chiller can be selected for operating temperature needs.  No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled

The HRZ series thermo-chiller is a high performance device for circulating fluid with a constant temperature. Available in 3 temperature range designs so the best chiller can be selected for operating temperature needs.  No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled

The ISA series is a non-contact style air catch sensor for applications requiring confirmation of work present for machining operations. Due to the construction of the sensor, fluctuations in the supply pressure does not influence operations. The ISA series is IP66 rated and is dust proof and drip proof. Air catch sensor, Operating pressure: 0.05 to 0.2MPa, Enclosure IP66, Port size: 1/8

The ISA series is a non-contact style air catch sensor for applications requiring confirmation of work present for machining operations. Due to the construction of the sensor, fluctuations in the supply pressure does not influence operations. The ISA series is IP66 rated and is dust proof and drip proof. Air catch sensor, Operating pressure: 0.05 to 0.2MPa, Enclosure IP66, Port size: 1/8

The ISA series is a non-contact style air catch sensor for applications requiring confirmation of work present for machining operations. Due to the construction of the sensor, fluctuations in the supply pressure does not influence operations. The ISA series is IP66 rated and is dust proof and drip proof. Air catch sensor, Operating pressure: 0.05 to 0.2MPa, Enclosure IP66, Port size: 1/8

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com