System: P (Vacuum Pump System, Single Unit), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor, 0 to -101, Analog Output 1 to 5 V), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting), Bracket: B [One Bracket for Mounting Single Unit
System: P (Vacuum Pump System, Single Unit), Valves: R (Supply Valve; Self-holding, Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor, 0 to -101, Analog Output 1 to 5 V), Connector: L1 (L-type Plug Connector Lead Wire for Pressure Switch), Vacuum, V Port: 09 (Inch Size, ø5/16" One-touch Fitting), Bracket: B [One Bracket for Mounting Single Unit, (Mounting
NOTE [ on] Display ON [F80] [ dSP] Display OFF mode [F81] [P in] Security code [oFF] Not used The direct current power supply used should be UL approved as follows. Circuit (class 2) of maximum 30 Vrms (42.4 V peak) or less, with UL 1310 class 2 power supply unit or UL 1585 class 2 transformer. The product is a UL approved product only if it has a mark on the body.
N Bracket dimensions With auto-drain Model Port size A B C D E F G H J K L M U (Body) V (Adapter) L 178 211 277 321 B 260 298 366 436 T 9 9 11 11 S 8 16 21 26 R 78 97 98 115 P 50 35 45 46.5 1/4, 3/8 1/4, 3/8, 1/2 1/2, 3/4 3/4, 1 1/4, 3/8 1/4, 3/8, 1/2 1/2, 3/4 3/4, 1 AMR3000 AMR4000 AMR5000 AMR6000 100 120 130 160 180 210 246 290 264 302 370 440 10 10 45 70 101 121 131 161 51 61 66 81 28
M ast er Pow er SU P. ( D C24V) PRO FI BU SD P Sl ave1 O t her D P equi pm ent Sl ave2 O t her D P equi pm ent The pressure proportional to the signal on the second side is obtained.
Vertical actuation I II P W A P a (b) (a) P P a A W (1) Basically adjusted with meter-out control. When meter-in control is also used, lurching is reduced. (1) Basically adjusted with meter-out control.
Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Bracket B, Horizontal Mounting, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: w/o Lead Wire, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: None, Operation Manual: Operation Manual, Calibration Certificate
Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Bracket A, Vertical Mounting, Operation Manual: Operation Manual, Calibration Certificate
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A, Vertical Mounting)
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8)
Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: -, Operation Manual: -
Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: -, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: SI Unit Only, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: -, Operation Manual: -
Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)