DIN 49.7) 23 8 70.6 [72.8] 39 2-5.5 (For mounting) 1/8 (P, R port) (Pitch) P=19 20 Manual override Approx. 300 (Lead wire length) (Station n) (Station 1) (Light/surge voltage suppressor) + + + + 57 [64] 41.6 25 1/8 (A port) 23 8 19.5 (Pitch) P=19 20 L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (W0) 53.5 53.5 53.5 53.5 3.4 87.1 3.4 3.4 3.4 70.7 [72.9] 80.5 [82.7]
End Detection A 22 D-A9 D-F9 D-F9 W B W 20 (22) A D-A9 V D-F9 V D-F9 WV W B Dimension inside ( ) is for model D-A9 V.
A L D VT KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 3.2 4 6 8 10 16 16 18 20.5 22 31.5 32 35 39 43 3.2 6 8 10 12 D VP Color: White VG VP L DIN rail 12.5 (Pitch) 5.25 7.5 AXT100-DR-l VQ Enter suffix the number from DIN rail dimensions table below.
) (in) D-B5 D-B6 D-C7 D-C80 D-C73C D-C80C D-B5 D-B6 D-C7 D-C80 D-C73C D-C80C D-B59W D-H7 D-H7C D-H7W D-H7BAL D-H7NF D-B59W D-H7 D-H7C D-H7W D-H7BAL D-H7NF D-H7LF D-G59 D-K59 D-H7LF D-G59 D-K59 Auto switch model Auto switch model B 0.42 0.31 0.52 0.51 0.56 0.83 B 0.86 0.59 0.76 0.85 0.75 1.20 A 0.94 0.78 1.00 1.23 1.13 1.58 A 0.94 0.78 1.00 1.23 1.13 1.58 B 0.50 0.39 0.60 0.59 0.64 0.91 B
M L 8 12 KPQL12-00 KPGL12-00 31.4 7.5 25 50 40 20 20.9 Note 1) D indicates the maximum diameter.
(Max. 20 stations) SUP/EXH block assembly mounting position Valve stations Series 3 5 7 02 2 stations SY3000 SY5000 SY7000 20 20 stations Symbol Mounting position U side D side Both sides Special specifications Applicable stations U D B M 2 to 10 stations 2 to 20 stations In case of special specifications, indicate separately on a manifold specification sheet.
Model Model L D L D TCU0805-1-N-X6 TCU0425-1-N-X6 1 N x 8 31 3 to 90 L x 5.2 + 200 N x 4 18 1 3 to 90 L x 5.9 + 200 8 5 TCU0805-2-N-X6 TCU0425-2-N-X6 2 42 3 to 40 L x 3 + 200 N x 16 L x 4.4 + 200 N x 8 2 3 to 90 4 2.5 28 TCU1065-1-N-X6 TCU0425-3-N-X6 1 52 3 to 45 L x 5 + 200 N x 10 N x 12 3 3 to 63 L x 2.9 + 200 28 10 6.5 TCU1065-2-N-X6 TCU0604-1-N-X6 2 3 to 35 N x 20 52 L x 3 + 200 N x 6
0 5 10 15 20 25 Circulating fluid flow rate [L/min] Circulating fluid flow rate [L/min] HRR050-A-20, HRR050-W-20 0.5 Circulating fluid pressure [MPa] Outlet: 60 Hz 0.4 0.3 Outlet: 50 Hz Return port Return port (Option Z) 0.2 Allowable operating range 0.1 0 0 10 20 30 40 Circulating fluid flow rate [L/min] Required Facility Water Flow Rate 012 018 024 030 HRR -W HRR010-W-20 30 20 Facility
Protrusion of Auto Switch from Edge of Body (L) MHT (mm) Air gripper model Auto switch model D-Y59 D-Y7P D-Y69 D-Y7PV MHY MHC2-10 MHC2-16 MHC2-20 MHC2-25 6 6 5 3 8 7 6 4 MHW MRHQ Auto Switch Hysteresis Misc. Auto switches have hysteresis similar to micro switches. Use the table below as a guide when adjusting auto switch positions, etc.
3 0.4 MRHQ 0.5 0.5 Misc. 1 2 2 0.3 0.4 0.4 D0.2 1 1 0.3 200 30 20 10 0 30 20 10 0 30 20 10 Gripping point L mm Gripping point L mm Gripping point L mm 12-8-11 12 Series MHC2/MHCA2/MHCM2 Confirmation of Inertial Moment of Attachment Step 2 Confirm the inertial moment of one of the two attachments.
22 3.2 6 8 10 12 3.2 4 6 8 10 31.5 32 35 39 43 D VT Color: White VP VG L DIN rail VP 12.5 (Pitch) 5.25 7.5 AXT100-DRS070 As for , enter the number from the DIN rail dimensions table. 25 35 5.5 VQ 12.5 L Dimension L = 12.5n + 10.5 VKF Each manifold can be mounted on a DIN rail.
5 V Current output*1 4 mA 4.16 mA 20 mA B D 0 L/min C*2 D Voltage output (0 to 10 V)*1*3 0 V 0.1 V 10 V Model Minimum value of rated flow range*4 Maximum value of rated flow range PF3A703H 30 L/min 3000 L/min PF3A706H 60 L/min 6000 L/min PF3A712H 120 L/min 12000 L/min A C 0 0 *1 Analog output accuracy is within 3% F.S. *2 A and C will change according to the setting of the zero cut function
(mm) D H Bore size B GA L LB GC GB C A LX LH MM NB Y X NA Z S LD 3.5 through, 6.5 depth of counterbore 4 9.5 28 8 M4 x 0.7 12 4 8 31.5 85 65 10 15 12 14 16 5 11 20 23 16 4.5 through, 8 depth of counterbore 5 5 9.5 16 15 18.3 20 16 5 11 20 26 20 8 28 M5 x 0.8 10 16 31.5 86 66 Specific Product Precautions Be sure to read before handling. Caution on mounting Caution 1.
L H L H L H 15 - 1020 /2 713 3 () 30%(F.S.) 25%(F.S.) 20%(F.S.) LEHZ(J) 10,16 20,25 32,40 LEHF 10 20 32,40 LEHS 10 20 32,40 / () 8.2 !
(Except L kit) U D U D The maximum and minimum number of stations are varied depending on kit. (Refer to the table below.)
Auto switch model D-A9 D-A9V D-F9BAL D-M9 D-M9V D-F9W D-F9WV Bore size (mm) B A B A B A 12 11 78 12 79 8 75 20 15 85 16 86 12 82 Operating Range Auto switch model Bore size (mm) 12 20 10 3 D-A9/A9V 6 D-M9/M9V D-F9W/F9WV D-F9BAL 2.5 3 5 Since this is a guideline including hysteresis, not meant to be guaranteed.
Bore size (mm) Stroke (mm) Bore size (mm) Manufacturable stroke range Applicable auto switch Note D25 50 100 75 125 150 175 200 250 300 400 500 12 25 to 150 D-A7/A80 D-A7H/A80H D-A73C/A80C D-A79W D-F7V D-F7/J79 D-J79C D-F7WV D-F7W/J79W D-F7BAL/F7BAVL D-F79F/F7NTL Switch mounting screw (M3 x 0.5 x 8l ) Square nut 12 20 -X BQ-1 20 25 to 300 32 2025 to 400 40 25 to 600 32 40 50 63 Switch
Model Flow range 0.5 L/min 2 L/min 5 L/min 10 L/min 20 L/min 50 L/min 100 L/min 200 L/min 0.5 L/min 20 L/min LFE1 0.4 L/min 24 L/min 0.4 L/min 24 L/min 2.5 L/min 100 L/min LFE2 2 L/min 120 L/min 2 L/min 120 L/min 5 L/min 200 L/min LFE3 4 L/min 240 L/min 4 L/min 240 L/min Rated flow range Display flow range Set flow range 21 These safety instructions are intended to prevent hazardous situations
-D DC(+) DC(-) (OUT1) (OUT2) ( ) GND 30 ms GND 30ms ( 20 ) -63No.PF-OMM0004-D OUT1 (OUT1)80 mA OUT2 (OUT2)80 mA 140 ( ( 1 ) 110 10 -64No.PF-OMM0004-D () PF3W704 PF3W720 PF3W740 PF3W711 PF3W721 (3 mPas(3 cP)) 1 0.54 L/min 216 L/min 540 L/min 10100 L/min 50250 L/min 3.555.0 L/min ( 3.5 L/min 0.0) 1.722.0 L/min ( 1.7 L/min 0.0) 0.355.50 L/min ( 0.35 L/min 0.00) 20350 L/min (
Operating Fluid and Ambient Temperature Tightness of Valve (Leakage Rate) NBR, FKM, EPDM Seal material Leakage rate (With water pressure) 0.1 cm3/min or less Operating fluid temperature (C) Solenoid valve option (symbol) Ambient temperature (C) Power source Nil, G, L E, P 1 to 99 1 to 60 1 to 40 20 to 60 20 to 40 AC DC Note) With no freezing 3 4 Direct Operated 2 Port Solenoid Valve Series