Especially in the case of small diameter pads. 6.When transporting in an upward direction, factors such as acceleration, wind pressure and impact force must be considered in addition to a workpiece weight. Use caution particularly when lifting items such as glass plates and circuit boards, because a large force will be applied by the wind pressure.

double (B) 2 (A) 4 (B) 2 (A) 4 Same manifolds as series SYJ3000 are prepared. 1 (P) 3 (R) 5 (R) 1 (P) 3 (R) SS5YJA3 Fill the same as SS5YJ3 3 position closed center 3 position closed center (B) 2 (A) 4 (B) 2 (A) 4 Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base model no. 1 (P) 3 (R) 5 (R) 1 (P) 3 (R) 3 position exhaust

V) Power supply voltage Communication type Communication protocol: Dedicated for SMC Communication speed : 750 kbps Current for input branch Max. 1 A per branch Power supply for input and controlling GW: Max. 4.1 A (Inside GW unit: 0.1 A, Input unit: 4 A) Power supply for output: Max. 6 A Current for output branch Max. 1.5 A per branch Rated current At 0.75 A per branch: 20 m or less At

40 60 80 100 Load N 0 20 40 60 80 100 Load N 0 50 100 150 200 250 Data 8-9-9 9 Series MXY Table Deflection Table deflection due to pitch moment load Displacement at A when load is applied F Table deflection due to yaw moment load Displacement at A when load is applied F Table deflection due to roll moment load Displacement at A when load is applied F A A F A F F L L L L dimension mm L dimension

L G ZA F H K J ZX I B C E D A ZR ZM 2 x M3 countersunk head screw mounting hole ZMA ZQ ZH ZU ZFC10, 20 ZL Applicable tubing O.D.

If this surface is to be used for mounting, a spacer composed of a non-magnetic substance (aluminum, etc.) is required as shown in the figure below.

As a rule, it should be turned about 90 past the point at which tightening can be felt.

Use caution, as there is a danger of being burned if a valve is touched directly. 2. Valves may reach high temperatures when continuously energized. Use caution, as there is a danger of being burned if a valve is touched directly. SOL. AC AC SOL. Without light AC SOL. Light With light 10 Series VCB Specific Product Precautions Be sure to read before handling.

Example: The figure below is based on the condition of set values as P1 = 40 [kPa] and P2 = 20 [kPa].

If the chewed portion of the tube is used as is, this can cause problems such as air leakage or difficulty in removing the tube. 2. When mounting a One-touch fitting, use a suitable wrench to tighten the hexagonal flats of the fitting. Moreover, position the wrench at the lower part of the hexagonal flats as close to the threads as possible.

1) (Station n) 48.5 [55.5] + + + + + 48.5 [55.5] 33.1 + + + + + 20 A A 33.1 20 5.1 (Pitch) P=10.5 18.5 One-touch fitting (A port) Applicable tubing O.D.: 4, 5/32" A A 5.1 (Pitch) P=10.5 18.5 M5 x 0.8 (A port) Station n L1 L2 3 58 50 Station 20 236.5 228.5 6 89.5 81.5 8 110.5 102.5 10 131.5 123.5 Station 2 47.5 39.5 4 68.5 60.5 5 79 71 7 100 92 9 121 113 11 142 134 12 152.5 144.5 13 163 155

PN01 Node address setting] or SII Configured Station Alias as necessary. You can set a node address as follows. After the node address setting is changed, cycle the power. Axis selection rotary switch (SW2/SW3) Pr.

As a guide, refer to the proper tightening torques shown below.

exhaust center 2(B) (A)4 2(B) (A)4 (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) How to Order Manifold Base 3 position pressure center 2(B) (A)4 Same manifolds as SYJ5000 series are prepared.

Low speed supply Initial operation return stroke PA PP B Cylinder movement with fixed orifice 2 1(P) 1/2 PP > PA Pressure stroke D PP 2(A) 1 3(R) B A C PA PR (atmospheric pressure) ON A Time When 1/2 PP PA after the cylinder reaches , piston B fully opens and PA increases rapidly as shown from to and becomes the same pressure as PP.

D2 D3 L1 L2 L3 L4 M1 L5 Weight T D1 H(1) D2 D3 L1 L2 L3 L4 M1 L5 H(1) A(2) A(2) AQ Weight (g) (g) Model Min.

Using pliers, snap A into B as shown below so that there is no gap between A and B, and secure the connector. The A and B portion of the sensor connector are already tacked down temporarily at the time of shipment. Do not snap the A portion in place before inserting the cable. Note that the connector cannot be taken apart to be reused once it is crimped.

Take care to avoid striking the cylinder tube with other objects or handling it in a way that could cause deformation. The cylinder tube and slider units have a non-contact construction. For this reason, even a slight deformation or slippage of position can cause malfunction and loss of durability, as well as a danger of degrading particulate generation characteristics. 2.

Applicable dryer Weight lb [g] A B A 0.8 [20] 0.8 [20] AME 8.7 [220] 9.4 [240] 0.08 [35] IDF-FL209 IDFB3E AMF IDFB4E 14.8 [375] 7.7 [195] 0.12 [55] IDF-FL203 B IDFB6E ZFC 13.3 [340] 0.15 [70] IDF-FL204 IDFB8E 10.4 [265] SF 14.8 [375] 0.17 [75] IDF-FL205 IDFB11E 0.4 [10] SFD [17.3] 440 [14.5] 370 [0.26] 120 IDF-FL206 IDFB15E LLB (IDF-FL209) (IDF-FL203 to 208, 213, 214) IDFB22E 21.7 [550] 14.4

B 1 0 A B 1 0 A B 1 0 A B 1 0 9 61.5 A A A A R4.5 26 62.5 97 = 4.5 (5.5) (35) (L3) (5.2) 52 (L4) Stations D side U side 1 2 3 4 5 6 7 8 n 2-C6 P(SUP) port P A P A A A A A A A 24.5 (11) 13.5 R B R B B B B B B B (7.5) 7 2-C6 R(EXH) port 19.2 P = 11 2n-C3, C4, C6, M5 C3: One-touch fitting for 3.2 C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5 threads Broken lines indicate DIN