SMC Corporation of America
Elite Part Number Search
Search Results "HRSH100-A-20-AS"

1) (Station n) 48.5 [55.5] + + + + + 48.5 [55.5] 33.1 + + + + + 20 A A 33.1 20 5.1 (Pitch) P=10.5 18.5 One-touch fitting (A port) Applicable tubing O.D.: 4, 5/32" A A 5.1 (Pitch) P=10.5 18.5 M5 x 0.8 (A port) Station n L1 L2 3 58 50 Station 20 236.5 228.5 6 89.5 81.5 8 110.5 102.5 10 131.5 123.5 Station 2 47.5 39.5 4 68.5 60.5 5 79 71 7 100 92 9 121 113 11 142 134 12 152.5 144.5 13 163 155

PN01 Node address setting] or SII Configured Station Alias as necessary. You can set a node address as follows. After the node address setting is changed, cycle the power. Axis selection rotary switch (SW2/SW3) Pr.

As a guide, refer to the proper tightening torques shown below.

exhaust center 2(B) (A)4 2(B) (A)4 (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) How to Order Manifold Base 3 position pressure center 2(B) (A)4 Same manifolds as SYJ5000 series are prepared.

Low speed supply Initial operation return stroke PA PP B Cylinder movement with fixed orifice 2 1(P) 1/2 PP > PA Pressure stroke D PP 2(A) 1 3(R) B A C PA PR (atmospheric pressure) ON A Time When 1/2 PP PA after the cylinder reaches , piston B fully opens and PA increases rapidly as shown from to and becomes the same pressure as PP.

D2 D3 L1 L2 L3 L4 M1 L5 Weight T D1 H(1) D2 D3 L1 L2 L3 L4 M1 L5 H(1) A(2) A(2) AQ Weight (g) (g) Model Min.

Using pliers, snap A into B as shown below so that there is no gap between A and B, and secure the connector. The A and B portion of the sensor connector are already tacked down temporarily at the time of shipment. Do not snap the A portion in place before inserting the cable. Note that the connector cannot be taken apart to be reused once it is crimped.

Take care to avoid striking the cylinder tube with other objects or handling it in a way that could cause deformation. The cylinder tube and slider units have a non-contact construction. For this reason, even a slight deformation or slippage of position can cause malfunction and loss of durability, as well as a danger of degrading particulate generation characteristics. 2.

Applicable dryer Weight lb [g] A B A 0.8 [20] 0.8 [20] AME 8.7 [220] 9.4 [240] 0.08 [35] IDF-FL209 IDFB3E AMF IDFB4E 14.8 [375] 7.7 [195] 0.12 [55] IDF-FL203 B IDFB6E ZFC 13.3 [340] 0.15 [70] IDF-FL204 IDFB8E 10.4 [265] SF 14.8 [375] 0.17 [75] IDF-FL205 IDFB11E 0.4 [10] SFD [17.3] 440 [14.5] 370 [0.26] 120 IDF-FL206 IDFB15E LLB (IDF-FL209) (IDF-FL203 to 208, 213, 214) IDFB22E 21.7 [550] 14.4

B 1 0 A B 1 0 A B 1 0 A B 1 0 9 61.5 A A A A R4.5 26 62.5 97 = 4.5 (5.5) (35) (L3) (5.2) 52 (L4) Stations D side U side 1 2 3 4 5 6 7 8 n 2-C6 P(SUP) port P A P A A A A A A A 24.5 (11) 13.5 R B R B B B B B B B (7.5) 7 2-C6 R(EXH) port 19.2 P = 11 2n-C3, C4, C6, M5 C3: One-touch fitting for 3.2 C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5 threads Broken lines indicate DIN

This can be prevented by inserting a noise filter, such as aline noise filter and ferrite core, between the switch-mode power supply and the product, or by using a series power supply instead of a switch-mode power supply. Hysteresis (H_1) Window comparator mode : For vacuum: High vacuum ON OFF 5.

Install a solenoid valve for braking as close to the cylinder as possible. If there is a long distance between the cylinder and valve, it may cause fluctuations in the stop accuracy or unexpected sudden slide table movements.

MY1CW16/20 MY1MW16/20 MX B A MTS Reed Switch Solid State Switch D-A90(V), D-A93(V), D-A96(V) (mm) D-M9N(V), D-M9P(V), D-M9B(V) D-F9NW(V), D-F9PW(V), D-F9BW(V) MY 16 20 Mounting position 16 20 Mounting position Mounting position 16 20 93 94 A A A 73 74 70 90 CY 107 106 B B B 87 86 90 110 6.5 7 8.5 6.5 Operating range Note) Operating range Note) Operating range Note) 11 7.5 MG CX MY1MW25/32

B Auto switch a b d c Proper mounting positions (mm) A B Bore size (mm) 63 80 100 10 13 17.5 14 18.5 23.5 Proper mounting positions (mm) a b 14 18 17 c 20 24 23 d D-A9 type D-F9 type D-F9 W type 2 6 5 8 12 11 In order that adjacent switches do not misoperate, they should be set within 1mm of the proper mounting positions indicated in the table above.

MY1CW16/20 MY1MW16/20 B A Reed Switch Solid State Switch D-A90(V), D-A93(V), D-A96(V) (mm) D-M9N(V), D-M9P(V), D-M9B(V) D-F9NW(V), D-F9PW(V), D-F9BW(V) 16 20 Mounting position Mounting position 16 20 A A B B Operating range Note) Operating range Note) Solid State Switch Reed Switch 24 Series MY1W Mounting of Auto Switch & Installation of Lead Wire Cover (50, 63) Caution Be sure to install

Do not connect the earth to a water pipe, a gas pipe, or a lightening rod. Do not plug too many leads into a single socket. That causes exothermic heat or fire.

The U-shaped groove is machined into the cushion ring in such a way that this acceleration process can proceed smoothly (as a sine function).

Plugging one of the cylinder ports (A or B) enables use as a 3 port valve. lt should not be used in special applications such as use as a non-leakage valve. Make sure the exhaust port is open if used as a 3 port valve. Solenoid {X) represents plugged port. common Exhaust ifflg"o,BJ"". rnd Pilot valve I Exhaust air from pilot valve will flow to main valve exhaust port.

Gasket Uni thread A ridge shape has been created as a Uni thread for common applications for Rc, G, NPT and NPTF. The male thread for piping drastically cuts piping man-hours. Applicable Tubing Tubing material Tubing O.D.