21 No.SFOD-OMT0011CN-A (4) (4-1) 4.2 (4-1) 4.2 JXCPC Online() PCJXC Online((Offline)) 22 No.SFOD-OMT0011CN-A (5) 5-1 4.3 4.6 (5-1) JXCPC () PCJXC ( 23 No.SFOD-OMT0011CN-A (6) 6-1 Current Alarm driver alarmcontroller alarm No. 4.8 (3) 4.8 (3) 4.8 (3) 24 No.SFOD-OMT0011CN-A 6-2 x : Axis x: Alarm History x No.
When the cylinder is used with a clamping mechanism, there is a danger of work pieces dropping out of it if there is a decrease in clamping force due to a drop in circuit pressure caused by a power outage. Therefore, safety equipment should be installed to prevent damage to machinery and human injury.
PB B A B A B A N.C. N.O. Double acting Double acting With flow rate adjustment PA PA N.C. B A PB B A Double acting N.C. Double acting With by-pass PA PA N.C. PB B A B A Double acting N.C. Double acting With flow rate adjustment & by-pass PA PA N.C. PB B A B A Double acting N.C.
Devise a safe system so that if a person engages the emergency stop or if a safety device is tripped during a system malfunction,such as a power outage, the operation of the magnet gripper will not cause a hazard to humans or damage the equipment. 7. Consider the action when operation is restarted after an emergency or abnormal stop.
Remote modeOpen A The time of FLT alarmClose FLT Operation stop FLT alarm status signal B The time of FLT alarmOpen A The time of WRN alarmClose WRN Continuing operation WRN alarm status signal B The time of WRN alarmOpen ALM Alarm status signal A The time of alarmClose B The time of alarmOpen RDY TEMP READY signal A TEMP READY statusClose B TEMP READY statusOpen A EnabledClose FREZ Anti-freezing
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
Devise a safe system so that if a person engages the emergency stop or if a safety device is tripped during a system malfunction,such as a power outage, the operation of the magnet gripper will not cause a hazard to humans or damage the equipment. 7. Consider the action when operation is restarted after an emergency or abnormal stop.
Devise a safe system so that if a person engages the emergency stop or if a safety device is tripped during a system malfunction,such as a power outage, the operation of the magnet gripper will not cause a hazard to humans or damage the equipment. 7. Consider the action when operation is restarted after an emergency or abnormal stop.
D 8 I m + mL kgm Find the gripper's moment of inertia. b a+b 12 I = m + mL kgm a Find the actual moment of inertia.
Y B G A 90 B 90 B G A D Note 1) 90 G A H X X X D Note 1) D Note 1) B B B F E F F E A H A G G RG RT RS B 296 305 C R310 R445 D 93 129 E 60 87 F 10 15 G 6 7 B 296 309 C R390 R495 D 93 129 E 60 87 F 10 15 G 6 7 B 299 307 C R350 R440 D 93 129 F 10 15 G 6 7 H 610 700 A 600 743 A 680 797 A 643 740 15 32 15 32 15 32 Y Note 2) Y Note 2) Y Note 2) X 558 to 573 685 to 708 X 518 to 533 558 to 581 X
Ensure input branch current does not exceed the specification range. 3 Mode No.4 Number of branch Valid port A OFF 16 points per port COM A and B B ON 8 points per port COM A to D Check the connection of UNLIT COM port branch to input unit. 4 COM A-D is not LIT 23 22
Remove a housing from a body by rotating 4 mounting screws counterclockwise with a hexagon wrench key. Hexagon wrench key Nominal: 5 2) Remove the valve guide. Hold the valve guide with a spanner on the spanner flat to rotate it counterclockwise and remove the valve guide. Spanner Nominal: 30 3) Remove the valve spring. 4) Remove the valve assembly.
Take sufficient shielding measures when installing at the following place. (1) A place where noise due to static electricity is generated (2) A place where electric field strength is high (3) A place where there is radioactive irradiation (4) A place near power line Do not use the product near by a place where electric surges are generated.
Remove a housing from a body by rotating 4 mounting screws counterclockwise with a hexagon wrench key. Hexagon wrench key Nominal: 5 2) Remove the valve guide. Hold the valve guide with a spanner on the spanner flat to rotate it counterclockwise and remove the valve guide. Spanner Nominal: 30 3) Remove the valve spring. 4) Remove the valve assembly.
Blanking block assembly (VCA30, 40) VVCA 3 0 2A 00 3 4 Series VCA30 Series VCA40 This is used when a blanking block is mounted on a manifold as preparation for a planned valve installation.
cable O.D.: 6.8 to 11.5) CE1 CE2 Proper Auto Switch Mounting Position D-H7 D-H7C D-H7NF D-H7W D-H7BAL D-C7 D-C80 D-C73C D-C80C ML2B D-G39 D-K39 D-A33/A34 D-A44 D-B5 D-B64 D-B59W D-G5NTL Bore size (mm) C J G5-S A B A B A B A B A B A B CV 20 56.0 31.5 50.0 25.5 55.0 30.5 51.5 27.0 53.0 28.5 49.5 25.0 25 MVGQ 56.0 31.5 50.0 25.5 55.0 30.5 51.5 27.0 53.0 28.5 49.5 25.0 32 59.5 36.5 53.5 30.5
Space at manual release Leave a space in order to release by hitting with a plastic hammer. 150 Min.
Normally open Normally closed Polycarbonate AD52 -A AD51 -A Nylon AD52 -6-A AD51 -6-A Metal AD52 -2-A AD51 -2-A 1 Enter the piping thread type to of the bowl assembly part number. Nil: Rc thread, N: NPT thread, F: G thread Please consult with SMC separately for psi and F unit display spccifications.
Do not use a stopper cylinder for intermediate stopping of loads directly connected to a cylinder, etc. The operating ranges shown in the catalog should only be used for stopping pallets on a conveyor. If loads connected directly to a cylinder, etc., are stopped with a stopper cylinder, the cylinder's thrust will become a lateral load. Please consult with SMC in this case. Danger 1.
Do not use a stopper cylinder for intermediate stopping of loads directly connected to a cylinder, etc. The operating ranges shown in the catalog should only be used for stopping pallets on a conveyor. If loads connected directly to a cylinder, etc., are stopped with a stopper cylinder, the cylinder's thrust will become a lateral load. Please consult with SMC in this case. Danger 1.