Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BJMT (B + J + M + T)
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: J (Automatic Water Supply Function)
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: B (Earth Leakage Breaker)
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: B (Earth Leakage Breaker)
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: MT (M + T)
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: T (High-pressure Pump)
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: JT (J + T)
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: W (SI Unit Only)
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: JM (J + M)
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BM (B + M)
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
THERMO CHILLER, CHILLER, 729, 40.00000 lb
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, MUFFLER 2 PT, AIRLINE EQUIPMENT, AN SILENCER, KB, AN 2 INCH STANDARD (PT), 2.17455 lb, ModelEffective area mm2Sonic conductance C [dm3/(s?
THERMO CHILLER, CHILLER, 729, 40.00000 lb
THERMO CHILLER, CHILLER, 729, 43 lb