USB 7. 106 No.SFOD-OMT0009CN-B 7. 7. 4. ( EMG ) 4. 107 No.SFOD-OMT0009CN-B 1. 1.1 LEY/LEYG LEY16/LEYG16 LEY25/LEYG25 LEY32/LEYG32 LEY40/LEYG40 A B C A B C A B C A B C [mm] 10 5 2.5 12 6 3 16 8 4 16 8 4 [mm] 300 300 300 400 400 400 500 500 500 500 500 500 [mm/s] 500 250 125 500 250 125 500 250 125 300 150 75 [mm/s] 15 8 4 18 9 5 24 12 6 24 12 6 () [mm/s] 22 12 6 26 13 7 34 17 9 34
(IN0IN5) DRIVE ON No.2(IN0IN5 ) DRIVE OFF No.2(OUT0OUT5 ) AREA OFF BUSY ON() INP OFF No.2 AREA ON(170mm ) No.2 AREA OFF(130mm ) BUSY OFF() INP ON -50mm 50mm No.1 200mm 1~2:150~250mm No.1 200mm 12150250mm No.2 100mm 1~2:130~170mm No.2 100mm 130170mm ON IN05 OFF Min15ms Min15ms DRIVE ON OFF OUT05 BUSY INP AREA 150mm 0mm/s 50mm 200mm 100mm 170mm 130mm No1 No2 No1 No2 INP ONOFF
(IN0IN5) DRIVE ON No.2(IN0IN5 ) DRIVE OFF No.2(OUT0OUT5 ) AREA OFF BUSY ON INP OFF No.2 AREA ON(170mm ) No.2 AREA OFF(130mm ) BUSY OFF() INP ON 50mm No.1 :200mm 1~2:150~250mm No.2 :100mm 1~2:130~170mm 50mm No.1 200mm 12150250mm No.2 100mm 130170mm ON IN05 OFF Min15ms Min15ms DRIVE ON OFF OUT05 BUSY INP AREA 150mm 0mm/s 50mm 200mm 100mm 170mm 130mm No.1 No.2 No1 No2 INP ON,OFF
2)GW DHCP DHCP DHCP ON()/OFF() GW PLC GWDHCPON() DHCP DHCPON()LEC-GEN1DHCPIPPLC(PLC :7) DHCPON()DHCPIPLEC-GEN1IP config IPPLC (PLC:37) GWDHCPOFF() DHCPLEC-GEN1IP configIPPLC (PLC:7) (3) RSLogix5000EtherNet/IP GW RSLogix5000EtherNet/IPRSLogix5000Module Properties Assembly instance InputOutputConfiguration Comm Format: Data-SINT Comnection Parameters Instance Size Input 100 256 Output 150
bracket) Model Specifications IDG60LA IDG75LA IDG100LA IDG60SA IDG75SA IDG100SA Compressed Air Fluid Range of operating conditions Inlet air pressure MPa 0.31.0 -550 -550 Inlet air temperature oC Ambient temperature oC Standard performance Outlet air atmospheric pressure dew point oC Inlet air flow rate L/min(ANR) 224 308 400 75 140 230 Outlet air flow rate L/min(ANR) 170 240 300 50 100 150
Please set up the application to consider the signals will be invalid within 150 ms after power is supplied. -5No.D-S-OMU0002-A (9) Install a rotation stopper to the actuator piston rod. Use a guide or select an SMC product with a rotation stopping function. The accuracy may decrease without a rotation stopper.
Actuator Specifications Supplement 1.1 Initial setting of LEY/LEYG series Model LEY16/LEYG16 LEY25/LEYG25 LEY32/LEYG32 LEY40/LEYG40 Lead symbol A B C A B C A B C A B C Lead [mm] 10 5 2.5 12 6 3 16 8 4 16 8 4 Stroke [mm] 300 300 300 400 400 400 500 500 500 500 500 500 Max. speed [mm/s] 500 250 125 500 250 125 500 250 125 300 150 75 Min. speed [mm/s] (Independent and 15 8 4 18 9 5 24 12 6 24
A Communication error occurred (01-150) RESET Communi
drain With drain With drain With drain With drain (Semi-standard: Z) (With color zone) switch drain fitting guide cock guide cock guide H J H J H J H J H J B B B B B B B AC20A-D 28 27 27.8 37.5 37.5 57.5 37.5 58.5 37.5 58.5 104.9 91.4 87.4 93.9 AC30A-D 28 32.5 27.8 43 37.5 63 37.5 64 37.5 64 157.1 123.9 122.2 118 122 138 142 AC40A-D 28 41.5 27.8 52 42.5 73 42.5 73 42.5 73 186.9 155.6 153.9 150
A B C D E F G H LAT3-50 50 75 6 25 150 140 54.5 70 14 - 3. 2 Card Motor Return to Origin The Card Motor uses an incremental type sensor (linear encoder) to detect the position of the table. Therefore, it is necessary to return the table to the Origin Position after the power has been switched on. There are three [Return to Origin Position] methods as described below.
The cylinder section does not have a water resistant enclosure. 3-3 Allowable Kinetic Energy 3-3-1 Allowable Kinetic Energy (J) Bore size(mm) 12 20 32 40 50 63 Allowable Kinetic EnergyE 0.022 0.055 0.15 0.26 0.46 0.77 3-3-2 Mass of Cylinder Movable Parts (g) Cylinder stroke (mm) Bore size(mm) 25 50 75 100 125 150 175 200 250 300 400 500 12 28 33 38 43 48 53 20 70 84 98 112 126 140 154 168
Heavy load Standard load Medium load Light load 1 10 50 100 200 1 0.25 0.49 0.98 1.96 2 20 2 0.49 75 200 400 0.74 1.47 2.94 3 30 3 0.74 100 300 600 0.98 1.96 3.92 4 40 125 400 800 4 0.98 1.23 2.45 4.90 5 50 5 1.23 150 500 1000 1.47 2.94 5.88 6 75 200 600 1200 6 1.47 1.96 3.92 7.84 7 100 250 700 1400 7 1.72 2.45 4.90 9.80 8 300 300 800 1600 8 1.96 2.94 5.88 11.76 9 500 500 900 1800 9 2.21
Tightening torque Nominal 1.40.1Nm 125 or 150 10. Mount the bowl assembly. AL20-A Referential tightening torque Hold the bowl assembly by hand and rotate clockwise. Do not use tool for mounting because the bowl may be damaged. See check item for referential tightening torque. 2.1 Nm Disassembly 1. Remove the bowl assembly.
Wiring diagram (Power supply and monitor output) Switch output NPN type Switch output PNP type ITV 0 0-52 ITV 0 0-53 When a current of approx.150 mA or more is applied, the over current circuit will operate, Er.5 will be displayed and the operation will stop.
The graphs below show the variation of the distance for the product to turn ON, for 3 types of gap, by changing the supply pressure (50 kPa) when the product is set to turn ON at 150 kPa supply pressure. Detection nozzle: 1.5 Piping: F type: 4 x 2.5 tube Test conditions G, H type: 6 x 4 tube Reference pressure: 150 kPa : Use within the rated pressure range (100 kPa to 200 kPa).
(between FE and all accessible terminals) Insulation resistance 10 M ohm or more (500 VDC is given between FE and all accessible terminals) Ambient temperature Operation: -10 C to 50 C Storage: -20 C to 60 C Ambient humidity 35% to 85% RH (non-condensing) 10 Hz to 57 Hz (constant amplitude) 0.75 mm 57 Hz to 150 Hz (constant acceleration) 49 m/s2 2 hours for each direction X, Y and Z (complies
Performance Performance data shown in this chapter is based on an electrified plate (dimensions: 150 x 150 mm, electrostatic capacity: 20pF) defined by ANSI standard (ANSI/ESD STM3.1-2006). Use this data as a guideline for selection, as the performance data may vary depending on the material and size of the work piece. 5 -1.
Round cutting pliers Nominal: 125 or 150 Tightening torque: 1.4 0.1 Nm 10) Mount the bowl assembly. Hold the bowl assembly by hand and rotate clockwise. Do not use tool for mounting because the bowl may be damaged. Refer to the Check item for referential tightening torque. Actuators Modular F.R.L.
150 130 120 50 50 MSZA30A (High precision type) MSZA50A(High precision type) D70 60 50 40 30 20 10 0 120 100 80 60 40 20 0 Load N Load N 291 Rotary Table Air Consumption Air consumption is the volume of air which is expended by the rotary tables reciprocal operation inside the actuator and in the piping between the actuator and the switching valve, etc.
Note 1) Note 2) Maximum available stroke (mm) Bore size (mm) 20 25 32 40 Standard stroke (mm) Model Long stroke (mm) 1 pc. 201 to 350 301 to 400 301 to 450 301 to 800 25, 50, 75, 100, 125, 150, 200 D-C7, C8 D-B5, B6 D-H7 D-G5N 15mm 10mm 1500 25, 50, 75, 100, 125, 150, 200, 250, 300 20mm 20mm 15mm 10mm D-B59W D-H7LF Note 1) Intermediate strokes other than the above are produced upon receipt