Auto Switch Mounting Height (mm) Auto switch model Band mounting D-C7m/C80 D-H7m/H7mW D-H7NF D-H7BA D-M9mV D-M9mWV D-M9mAV D-A9mV D-M9m D-M9mW D-M9mA D-A9m D-C73C D-C80C D-H7C D-A7m D-A80 Hs Hs Hs Hs Hs Hs Bore size 10 17 18 17 19.5 20 16.5 16 20.5 21 20.5 23 23.5 19.5 (mm) Auto switch model Rail mounting D-M9m D-M9mV D-M9mW D-M9mWV D-M9mA D-M9mAV D-A9m D-A9mV D-A7mH/A80H D-F7m/J79 D-F7mW

Static Neutralization Characteristics (Discharge Time from 1000 V to 100 V) (1) Energy saving static neutralization nozzle/IZN10-01 (2) High flow rate nozzle/IZN10-02 5 5 0.1 MPa 0.05 MPa 4 4 0.3 MPa 0.05 MPa Discharge time [s] Discharge time [s] 3 3 0.1 MPa 2 2 0.7 MPa 0.3 MPa 1 1 0.5 MPa 0.5 MPa 0.7 MPa 0 0 200 400 0 0 400 200 Distance [mm] Distance [mm] (3) Female threads for piping/IZN10

consumption (W) Max. operating frequency (Hz) A 80 1200 B 40 1000 C 10 550 D 4 350 E Note) Two mounting screws (M3 x 0.5) and a gasket are included.

Mounting correctly Mounting incorrectly Solid state D-G59, D-G5P, D-K59, D-G5BA D-G59W, D-G5PW, D-K59W D-G59F, D-G5NT, D-G5NB Solid state D-H7A1, D-H7A2, D-H7B, D-H7BA D-H7C, D-H7NF, D-H7NW, D-H7PW, D-H7BW Reed D-C73, D-C76, D-C80, D-C73C, D-C80C Reed D-B53, D-B54, D-B64, D-B59W Auto switch Auto switch Auto switch mounting screw M3 x 0.5

Note D-F7/J79 D-F7V D-J79C D-F7W/J79W D-F7WV D-F7BAL/F7BAVL D-F79F D-F7NTL Switch mounting screw RS H A 20, 25 BQ-1 (M3 x 0.5 x 8l) Square nut D-A7/A8 D-A73C/A80C D-A7H/A80H D-A79W RZQ Switch mounting screw 32, 40 50, 63 Magnetic body (Steel plate, etc.)

A /B 90 0.1mm/ 2-1. 2-2 F.G CE1-R** CE1 CEU5 OUT1OUT5 RS-232C OUT1OUT20(bank ) (31 ) 221 () B L F G D 0.5 L 3 Z 12 12mm 20 20mm 32 32mm 40 40mm 50 50mm 63 63mm 4063 N R H (mm) (mm) (mm) 25 50 75 100 125 150 175 200 250 300 400 500 12 20 32 40 50 63 222 A90 D-A90 M9N D-M9N M9NW D-M9NW A93 D-A93 M9P D-M9P M9PW D-M9PW A96 D-A96 M9B D-M9B M9BW D-M9BW A90V D-A90V M9NV D-M9NV

, D-A9V D-M9, D-M9V D-F9W, D-F9WV 5 5 5 1 pc. 10 5 10 2 pcs.

(In this case, be sure to connect a reverse voltage suppression diode.) + +V D OUT OV X Relay Other Warning 1. Consult SMC concerning water resistance, flexibility of lead wires, and usage at welding sites, etc. 98

MDHR2-20, 30 MDHR2-10, 15 H H L L Auto switches of D-M9NV, D-M9PV, D-M9BV, and D-M9AV are used. Auto switches of D-M9N, D-M9P, D-M9B, and D-M9A are used. Auto switches of D-M9NV, D-M9PV, D-M9BV, and D-M9AV are used. Max. Protrusion of Auto Switch from Edge of Body: L, H Max.

How to Order B 20 30 D C CQSY Without auto switch F9BW S B 20 30 D C CDQSY With auto switch Number of auto switches Built-in magnet 2 pcs. 1 pc. n pcs.

Z 11 Lead wire min. bending radius 10 Auto switch D-A7, A8 K M E S J B + Stroke A + Stroke L Rod end male thread H1 Rod end nut C1 X L1 Rod End Male Thread (mm) Bore size (mm) 63 Auto switch D-A9, F9 C1 X H1 L1 26 28.5 M18 x 1.5 33.5 80 32.5 35.5 M22 x 1.5 43.5 100 32.5 35.5 M26 x 1.5 43.5 (mm) Without auto switchWith auto switch Bore size (mm) Stroke range (mm) C D E F H I J K L M N O P

, A90V D-A93, A93V D-A96, A96V Series CQSW Basic Non-rotating Rod 12 16 5, 10, 15, 20 25, 30 How to Order . 1 Construction . 9 20 25 5, 10, 15, 20 25, 30, 35, 40 45, 50 12, 16 20, 25 Dimensions ...10 &11 Series CQS How to Order . 1 12 16 20 25 5, 10 Construction . 12 Solid state switch D-M9N, F9NV D-M9P, F9PV D-M9B, F9BV D-F9NW, F9NWV D-F9PW, F9PWV D-F9BW, F9BWV Dimensions ...13 to 16 Series

/F8P/F8B D-M9N/M9P/M9B When detecting extended stroke end When detecting retracted stroke end 10 mm or more 10 mm or more (2) 1 1 3 7 Stroke 3 + Stroke 7 CUJ CU CQS Note 1) Solid state switch: D-M9 includes one auto switch.

D-H7W D-H7BAL D-H7NF D-A73C D-A80C D-H7C D-A79W D-F7 D-F7W D-J79 D-J79W D-F7BAL D-F79F D-J79C Auto Switch Mounting Position (mm) D-A7H/A80H/A72 D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C/F7BAL D-F79F D-H7 D-H7C D-H7W D-H7BAL D-H7NF D-C7 D-C80 D-C73C D-C80C D-A73 D-A80 D-A79W Bore B A B A B A B A B A 32 8 (6) 7 (5) 8.5 (6.5) 14.5 (11.5) 9 (7) 8 (6) 7 (5) 6 (4) 6 (5) 12 (9) 40 10 (11) 12 (9) 7.5

of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com D-H7 D-H7W D-H7BAL D-H7NF D-A73C D-A80C D-H7C D-A79W D-F7 D-F7W D-J79 D-J79W D-F7BAL D-F79F D-J79C Auto Switch Mounting Position (mm) D-A7H/A80H/A72 D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C/F7BAL D-F79F D-H7 D-H7C D-H7W D-H7BAL

U side D side D D D D D D 3 2 1 Stations How to Order Solenoid Valve 10 SV 1 1 0 0 F 5 Note) Clean series Note) Available with manifold block for station additions. Refer to the WEB catalog.

The CNA2 series cylinder with lock is suitable for mid-stroke stops, emergency stops, and drop prevention. An equal holding force in extending and retracting directions make it possible to lock at either end of the stroke. High reliability and stable holding force are maintained by using a substantially lengthened brake shoe with superior wear resistance. The locking mechanism is isolated

-1 S Series Introduction .D-27 How To Order.D-28 90.D-29 Repair Kits .D-33 Seal Options .D-33 PS Series Introduction .D-4 How To Order.D-5 In-Line.D-6 90.D-15 Repair Kits .D-26 Seal Options .D-26 D Swivels Quick Coupling Division 8145 Lewis Road Minneapolis, MN 55427 www.parker.com/quickcouplings D-3 Introduction PS Series Swivels Introduction Features The design and manufacturing processes