Temperature characteristics Current consumption (No load) Weight Note 3) Port size (Rc, NPT, G) Detection type Indicator light Operating pressure range Proof pressure Accumulated flow range Note 4) 0 to 50C 5% F.S. or less 1% F.S. or less 2% F.S. or less 3% F.S. or less (15 to 35C, based on 25C), 5% F.S. or less (0 to 50C, based on 25C) 160 mA or less 170 mA or less 290 g 150 mA or less 250
After removing the cause of the alarm or warning, the alarm or warning can be deactivated in any of the methods marked in the alarm / warning deactivation column. "6" of the figure, "B" of the alphabet, and "D" are displayed as follows. 6 B D 7.1 Alarms List This section provides list of alarms.
Note) X465 AMR Note) Except symbol G ITV IC Switch specifications Output specifications NPN output PNP output 1 to 5 V output 4 to 20 mA output Symbol A B C D VBA VE VY1 With digital pressure switch G PPA Note 1) Please contact SMC separately for details about the external dimensions, etc.
, CFM x 102 l/min, CFM x 101 Display unit Note 1, 2) Real-time flow rate Accumulated flow l, ft3 x 101 0 to 50C 5% F.S. or less Operating fluid temperature Linearity Repeatability Temperature characteristics Current consumption (No load) Weight Note 3) 1% F.S. or less 2% F.S. or less 3% F.S. or less (15 to 35C, based on 25C), 5% F.S. or less (0 to 50C, based on 25C) 290 g 150 mA or less 250
Standard motor LJ1H202NF-K 100W to 250 [Tamagawa Seiki Co., Ltd.]
C N.C. dauto drain (dd AMG 150 sso) D N.O. daulo drain (dd. AMG 650 s5o) AMG 250 N I Body Size.
Multistage Ejector (N)ZL112 with Valve and (N)ZL212 Large Flow Type (N)ZL Series 3 Stage Construction Optional Supply & Release Valves Optional Pressure Sensors Series (N)ZL Multistage Ejector Energy saving, high flow, 3 stage diffuser construction Suction flow rate increased 250% and air consumption reduced 20% with 3 stage diffuser construction (Versus 1.3, single stage model) 1 stage
If the variable orifice is closed (turn the adjustment knob counterclockwise), all LED's are off. d When opening the variable orifice (turn the adjustment knob clockwise) the LED's will light up in the following order: Red 1, Red 2, Green 1, Green 2 f When the LED Green 1 is on, the output is energized.
1 EJECTOR MULTISTAGE Multistage Ejector Series ZL112/212 Energy-saving, large flow rate, 3 stage diffuser construction ZX Suction flow rate increased 250% and air consumption reduced 20% with 3 stage diffuser construction (Versus 1.3, one stage model) 1 stage perf stage perfor ormance mance 1 stage performance Vacuum pressure ZR Q1 Q2 Q3 ZM Q1 Q2 Q3 Maximum suction flow rate (l/min (ANR))
D-M9A Auto switch Auto switch B A (22) 22 B A Hs Hs 24.5 ( ): For D-A96 type 16 16 A B A B Hs Hs D-C7 D-C8 D-C73C D-C80C D-H7 D-H7W D-H7NF D-H7BA D-H7C B A Hs B Hs A Auto Switch Proper Mounting Position Auto Switch Mounting Height Auto switch model (mm) (mm) RSQ D-H7BA D-H7W D-H7 D-H7C D-H7NF D-H7 D-H7W D-H7NF D-H7BA D-C7/C8 Auto switch model D-C7 D-C80 D-C73C D-C80C D-M9V D-M9WV D-M9AV
Auto Switch Mounting Height (mm) Auto switch model Band mounting D-C7m/C80 D-H7m/H7mW D-H7NF D-H7BA D-M9mV D-M9mWV D-M9mAV D-A9mV D-M9m D-M9mW D-M9mA D-A9m D-C73C D-C80C D-H7C D-A7m D-A80 Hs Hs Hs Hs Hs Hs Bore size 10 17 18 17 19.5 20 16.5 16 20.5 21 20.5 23 23.5 19.5 (mm) Auto switch model Rail mounting D-M9m D-M9mV D-M9mW D-M9mWV D-M9mA D-M9mAV D-A9m D-A9mV D-A7mH/A80H D-F7m/J79 D-F7mW
, D-A9V D-M9, D-M9V D-F9W, D-F9WV 5 5 5 1 pc. 10 5 10 2 pcs.
D-A72/D-A73/D-A80 Band Mounting Style . D-A7xH/D-A80H Rail Mounting Style. D-A73C/D-A80C Rail Mounting Style . D-A5x/D-A6x Tie-rod Mounting Style. D-90/D-97 Direct Mounting Style . D-A90(V)/D-A93(V)/D-A96(V) Direct Mounting Style . D-90A/D-93A Direct Mounting Style . D-R73/D-R80 Direct Mounting Style. D-R73xC/D-R80xC Direct Mounting Style . 2-color Indication Type Reed Switch .
Auto Switch Mounting Dimensions D-Z7, D-Z8 (Reed switch) D-Y5, D-Y6, D-Y7 (Solid state switch) Dimension A Bore size Switch types 6 10 15 20 25 32 A D-Y59A, D-Y7P, D-Y59B D-Y69A, D-Y7PV, D-Y69B D-Y7NWV, D-Y7PWV, D-Y7BWV D-Y7NW, D-Y7PW, D-Y7BW D-Y7BAL D-Z7, D-Z8 0.2 0.7 6.0 0.7 6.5 1.2 Auto Switch Mounting Caution When mounting and securing auto switches, they should be inserted into the cylinder's
Auto Switch Specifications D-Y5, D-Y6, D-Y7P, D-Y7PV (with indicator light) D-Y59A, D-Y69A D-Y59A D-Y69A D-Y7P D-Y7PV D-Y59B D-Y69B Auto switch model no.
Note 12 16 20 25 32 40 50 D-F7 , J79 D-F7 V D-J79C D-F7 W, J79W D-F7 WV D-F7BAL, F7BAVL D-F7 F D-F7NTL D-F7, D-F7V D-J79, D-J79C D-F7W, D-F7WV D-J79W D-F7BAL, D-F7BAVL D-F7NTL, D-F79F Switch mounting screw (M3 x 0.5 x 10 ) Switch spacer Switch mouinting nut D-A7 , A80 D-A73C, A80C D-A7 H, A80H D-A79W 6 6 6 32, 40 50 BQ-2 D-F7LF 8 7 8 D-F9V D-F9W, D-F9WV D-F9BAL Switch mounting bracket Switch
(RedGreenRed) D-Y7BWV D-Y7BW D-Y7NWV D-Y7NW D-Y7PW Perpendicular D-Y7PWV Auto switch part no.
D-F9P D-F9G D-F9H D-F9GL D-F9HL D-F9B D-F9NL D-F9PL D-F9BL N.O.
Mounting Type D-Y59 , D-Y69 , D-Y7P(V) A B A B Auto Switch Specifications Grommet D-Y5, D-Y6, D-Y7P, D-Y7PV (with indicator light) D-Y59B D-Y7P D-Y7PV D-Y69A D-Y59A Perpendicular D-Y69B Auto switch part no.