The kinetic energy can be calculated using the formula below. 2 1 = I E E: Kinetic energy [ J ] 2 I: Moment of inertia [ 2 m kg ] : Angular speed [ s rad ] There is a threshold of kinetic energy that a rotary actuator allows. Therefore, by finding the moment of inertia, it is possible to find the threshold value of the rotation time.
VKF (A) 2 (A) 2 VQZ 1 (P) 3 (R) 1 (P) 3 (R) VZ VS VFN r e w q r e w q N.O. N.O. (A) 2 (A) 2 1 (P) 3 (R) 1 (P) 3 (R) Component Parts Description Material Note No.
r e w q r e w q VG VP S070 VQ VKF N.C.
Manifold mounting 3 D E DIN rail mount type Direct mount type 2.
ZP3P-20PTSF ZP3P-25PTSF ZP3P-35PTSF ZP3P-50PTSF p. 2 q Pad unit With Buffer p.6 e Buffer assembly Pad diameter Part no. 20 25 35 50 Dimensions ZPB2(J/K)10-B5 V V ZPB2(J/K)20-B5 V V ZPB3(J/K)10-B01 V V ZPB3(J/K)20-B01 V V p. 12 e Buffer assembly w T female thread adapter Pad diameter Part no. 20 25 35 50 Dimensions ZP3PA-T1-B5 V V ZP3PA-T2-B8 V V w T female thread adapter p. 11
Rod end nut 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 Clevis pin 50 Standard Locking release bolt (N type only) 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 63 Single knuckle joint 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 80 Double knuckle joint (with pin) Option 100 25, 50, 75, 100, 125, 150,
For manifold type 31, S31, 32, S32 Body option 5 port 0: Pilot valve individual exhaust for the pilot valve 3: Common exhaust type for main and pilot valve (With gasket and screws) D: Push-turn locking slotted type M5: With M5 port sub-plate For sub-plate, manifold type 41, S41, 46, S46 R port P, E port R port P, E port Electrical entry 24, 12, 6, 5, 3 VDC 100,110, 200, 220 VAC 24, 12, 6,
The D sub connector (25 pin) conforms with MIL standards, permitting use of commercially available connectors with wide interchangeability.
(Unclamping side) Bore size Nil Without lock L With lock 32 32 mm Auto switch type Nil Without auto switch (Built-in magnet) C D-P3DWASC E D-P3DWASE N D-P3DWA L D-P3DWAL Z D-P3DWAZ Guide pin diameter Mounting surface position (viewed from top) For guide pin diameter, refer to Table 1 below.
port size) Built-in One-touch fittings Applicable tubing O.D. 8 C8 Applicable valve model Piping P, E port Port size Symbol VV3Z4-S50: only C6 & C8.
Consult SMC for other voltages. 2.9-12 Series VQ100 Plug Lead Unit Manifold (VV3Q12) L1 10.8 3.5 5 L2 3 P E 8.9 P E 11 Round head screw M1.7 X 14 W (L type) 28.7 26.5 W (M type) 300 33.8 300 2-3.5 Mounting hole 4-M5 SY P, E port Manual override SYJ 11.5 P=10 300 Latching, 100V AC or more VK H (M type) U side D side n 5 4 3 2 1 300 H (L type) VZ VT VT 42.2 L type M type 36.3 VP W
(W0): SYJ7220-W0-01 Approx. 300 (Lead wire length) 65 31.5 [38.5] Max. 10 57.5 16.1 46.2 31.1 M8 x 1 36 18.5 Approx. 300 (Lead wire length) 42.6 [49.6] 2-3.2 (For mounting) 2-3.2 127.2 [131.6] 2-3.2 2-3.2 (For mounting) (For mounting) 107.6 [112] (For mounting) 125.4 145.4 147.2 110.6 97.6 65.6 35 35 35 35 21 21 25 21 25 21 Pg7 28 25 28 25 28 Applicable cable O.D. 3.5 to 7 28 Refer to the
Magnet: Built-in, Mounting: Axial Foot, Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 1000mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: -, Number: -
Magnet: Built-in, Mounting: Axial Foot, Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 125mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Axial Foot, Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 125mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: Spring/Air Pressure Lock, Auto Switch: F59--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Axial Foot, Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 125mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: Spring/Air Pressure Lock, Auto Switch: J59--Solid State, Gen. Purpose, 2 Wire, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Axial Foot, Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 175mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: J59W--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewied Connector: 3m, Number: 1 pc.
Magnet: Built-in, Mounting: Axial Foot, Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 200mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A53--Reed, DC Volt >5<24, LED, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Axial Foot, Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 200mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: B53--Reed, DC Volt >5 <24, LED, Lead Wire or Prewied Connector: -, Number: -
Magnet: Built-in, Mounting: Axial Foot, Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 250mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: F5P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewied Connector: 5m, Number: -