VT/O317-G(-02) VT/O317-GS(-02) VT/O317-H(-02) VT/O317-HS(-02) VT/O317-C(-02) VT/O317-CS(-02) VT/O317-T(-02) VT/O317-TS(-02) VT/O317-TZ(-02) VT/O317-D(-02) VT/O317-DS(-02) VT/O317-DZ(-02) Coil assembly with terminal part no. Coil no.
CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Number of auto switches Built in magnet Nil S n 2 pcs. 1 pc. n pcs.
I PORTOPORTLOOP SEC mm2/s LABEL PRO Main modes ALM mm/s L C RUN Directs a program operation. Operation mode ACTUATOR & CONSTRUCTION SYSTEM CONTROLLER POWER ALARM STOP JOG Executes a JOG operation. JOG operation mode HOLD /BS UP L R MON Monitors operating condition. Monitor mode DOWN MODE ENT /ESC Directs alarm code display and clear.
[%F.S.] 2.5 2.0 1.5 1.0 0.5 0.0 0 1 2 3 4 5 Response time[s] [s] Operating pressure range Pressure [MPa] Operating range Fluid temperature [oC] When fluids with high temperature are used, the operating pressure range will be reduced. Operate within the range mentioned above.
Dimensions/40 to 100 Basic/CA2YB 4-J 2-P (Rc, NPT, G) MM Width across flats KA G G D E H1 AL B1 K A N F N B C M S + Stroke H ZZ + Stroke (mm) Bore size (mm) 40 50 63 80 100 Stroke range Up to 500 Up to 600 Up to 600 Up to 700 Up to 700 B C A AL B1 D E F G H H1 J K KA M MM N P S ZZ 30 35 35 40 40 27 32 32 37 37 60 70 85 102 116 22 27 27 32 41 44 52 64 78 92 16 20 20 25 30 32 40 40 52 52 10
Dimensions/20 to 100 Basic/CG1YB GA GB 2-P (Port size) (Rc, NPT, G) 2-TC Section TA/TB Width across flats B1 H1 MM 0 -0.05 I 0 -0.05 TD E D E AL A TA TB 4-TC K F F H TE TF TG NA S + Stroke ZZ + Stroke KA C 0.1 8-J NA Section TA/TB (mm) Bore size (mm) 20 25 32 40 50 63 TC TDH9 TE TF TG M5 x 0.8 4 0.5 5.5 +0.08 0 8 +0.08 0 M6 x 0.75 5 1 6.5 10 +0.08 0 M8 x 1.0 5.5 1 7.5 12 +0.08 0 6 1.25 8.5
U Min. bending radius of lead wire 10 Auto switch K M L B + Stroke A + Stroke E J S Note) This drawings above show type D-A7 and D-A8 reed switches. The values shown inside ( ) are for switches other than types D-A7 and D-A8. S and U dimensions for connector type auto switches (D-A7C, D-A80C, and D-J79C) are 7mm greater.
U Min. bending radius of lead wire 10 Auto switch K M E J S B + Stroke L + Stroke L A + 2 strokes Note) The drawings above show type D-A7 and D-A8 reed switches. The values shown inside ( ) are for switches other than types D-A7 and D-A8. S and U dimensions for connector type auto switches (D-A7C, D-A80C, and D-J79C) are 7mm greater.
h Nil L R S Operating direction Left Right a b h g d c f e Note) Lead wire length symbols 0.5m .
The product has a fan(s) and could cause serious danger to operators. 8.2 Specifications Cool outlet air (10oC) can be supplied.
Insulation type Electrical entry Electrical option Class B G C D, T S Note) S L, Z 1 (100 V) 2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) 5 (24 V) 6 (12 V) AC DC Note) Surge voltage suppressor is attached in the middle of a lead wire. 17-3-72 3 The VX series will be revised shortly.
[Option] Conforms to ISO 15407-2 Standard Size 18 mm, 26 mm Plug-in Type 5 Port Solenoid Valve Series VS 8-2/VS 8-4 S R S R Series VS 8-4 S R Series VS 8-2 S R Conforms to ISO 15407-2 Standard S R S R ISO Standard: Interface conforming to 18 mm size (VS 8-2) and 26 mm size (VS 8-4) Accommodates IP65 enclosure.
How to Order Manifold Assembly Example (VV5FA3-30) Closed center VFA3330-02 (1 set) Double solenoid VFA3230-02 (1 set) Single solenoid VFA3130-02 (3 sets) Manifold base (5 stations) D side U side VV5FA3-30-051 Stations 1 3 2 VV5FA3-30-0511 set (Type 30, 5-station manifold base part no.) VFA3130-023 sets (Single part no.) VFA3230-021 set (Double part no.)
Stations Ports 1, 3, 5 position Symbol 02 Stations 2 stations Note U D B U side (2 to 10 stations) D side (2 to 10 stations) Both sides (2 to 20 stations) Note 1) Double wiring specifications 16 02 16 stations 2 stations Supply/Exhaust block assembly specification Note 2) Specified layout (Up to 32 solenoids possible.) 20 20 stations Nil S R RS Internal pilot specification Internal pilot
SI unit for SV series valves ( EX500-S 01 ) ( EX500-Q 02 ) PWR PWR COM COM 64.4 80.3 64.4 28 66 84.8 79.4 68.5 80.3 series 54.5 60 60 43.2 43 43.2 22.2 22 22.2 13 10.5 28.6 44 0 1 36 10.5 1 0 22 23 The mounting and removing methods of SI unit are as shown below.
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-15 Connection of RS-232C HRS Series 3.3Installation 3-27 HRX-OM-S004 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.
Kodanska 46, CZ-100 10 Prague 10 Phone: 02-67154 790, Fax: 02-67154 793 Hungary SMC Hungary Kft. Budafoki ut 107-113, 1117 Budapest Phone: 01-204 4366, Fax: 01-204 4371 Sweden SMC Pneumatics Sweden A.B. Ekhagsvgen 29-31, S-14105 Huddinge Phone: 08-603 07 00, Fax: 08-603 07 10 Ireland SMC Pneumatics (Ireland) Ltd. 2002 Citywest Business Campus, Naas Road, Saggart, Co.
Motion on RECL32-300 ML1C REA REC Pressure fluctuation Load fluctuation Speed fluctuation RHC 0.5 0.5 0.3 0.5 Pressure (MPa) Pressure (MPa) Pressure (MPa) Reducing actuation cycle time 10 10 30 10 Load (kg) Load (kg) Load (kg) MTS 100 300 300 Speed (mm/s) Speed (mm/s) Speed (mm/s) 300 CC Max. 500mm/s of high speed transfer is possible.
DXT170-176-2-01 DXT170-176-2-02 DXT170-176-2-03 DXT170-176-2-04 DXT170-176-2-07 DXT170-176-3-51 DXT170-176-3-06 DXT170-176-3-05 DXT170-176-3-53 For Series VZ300/500 With light/surge voltage suppressor With surge voltage suppressor 100 VAC 200 VAC 110 VAC 220 VAC 240 VAC 6 VDC 12 VDC 24 VDC 48 VDC S E For VZ120 Indicator light is not available for grommet type.
For AC voltage valves there is no S option. It is already built-in to the rectifier circuit. With light/surge voltage suppressor (Non-polar type) DC specifications of type D and DO is only available with 12 and 24 VDC. For AC voltage valves there is no S option. It is already builtin to the rectifier circuit. For type R and U, DC voltage is only available.