A B C NBR seal FPM seal EPR seal B Refer to Table q for application. 2 0 1 A VNA 15A Air operated VNA 15A 1 2 1 1 A T External pilot solenoid Manual override Rated voltage Valve size Port size Valve style Symbol Symbol 2 200V AC 50/60Hz 1 100V AC 50/60Hz Orifice size (mm) Symbol Port size RC(PT) 1 2 3Note) Valve size 1 to 4 3 110V AC 50/60Hz N.C. N.O.
Grade 4 M4.5 ISO class 6 10 M5.5 ISO class 7 0.1 0.5 1 1 M6.5 ISO class 8 Particle diameter (mm) Selection procedure (1) Required clean room cleanliness? Class M2.5 or Class M3.5 or Class M4.5? Diagram 1 Air flow (2) Air flow to the workpiece (Refer to Diagram 1.) Workpiece A The air flow is blocked before it reaches the workpiece.
As a guide, turn 90 from the position where it comes to feel tight. Set the tightening torque of a hexagon socket head set screw (M4 x 0.7) to be 1 to 1.2 Nm. 1. Fix it to the detecting position with a set screw by installing a mounting bracket in cylinder tie-rod and letting the bottom surface of a mounting bracket contact the cylinder tube firmly. (Use hexagon wrench) 2.
center (A) 4 (B) 2 SX q t r w 5 (R) 3 (R) 1 (P) (B) 2 (A) 4 3 position exhaust center (A) 4 (B) 2 5 (R) 3 (R) 1 (P) 3 position pressure center u (A) 4 (B) 2 3 (R) 1 (P) 5 (R) (This figure shows a closed center type.) 5 (R) 3 (R) 1 (P) Component Parts Replacement Parts Note Zinc die-casted Part no.
When used without a guide for a light load. (Application Example 1) When space is very limited.
A phase B phase Signal 2 (1) A scale of magnetic layers and non-magnetic layers with a pitch of 0.8mm is cut into the piston rod. (2) With movement of the piston rod, a sin, cos 2-phase signal (Signal 1) is received by the magnetic resistance element. For this wave form, 1 pitch (0.8mm) becomes exactly 1 cycle. (3) This is amplified and divided into 1/8 parts.
Excessive load will be applied to the piston rod, resulting in damage to the actuator and a reduced service life of the product. Model EQY16 EQY25 EQY32 Lead A B C H A B C H A B C Work load [kg] 1 1.5 3 1 2.5 5 10 2 4.5 9 18 9.
The brown [red] lead wire or terminal No.1 is (+) and the blue [black] lead wire or terminal No.2 is (). 1) If connections are reversed, a switch will operate, however, the light emitting diode will not light up. Also note that a current greater than that specified will damage a light emitting diode and it will no longer operate.
The brown [red] lead wire or terminal No.1 is (+) and the blue [black] lead wire or terminal No.2 is (). 1) If connections are reversed, a switch will operate, however, the light emitting diode will not light up. Also note that a current greater than that specified will damage a light emitting diode and it will no longer operate.
(With stroke adjuster at extension end) 3.5 (With stroke adjuster at retraction end) 26 58 35 62 48 5H9 depth 4 +0.030 0 F 20 18 N 1 x F 2 2-M6 x 1 thread depth 10 41 5H9 depth 4 +0.030 0 30 M 0.5 37.5 40 Z ZZ (NN1) x H G 10.5 24 10.5 24 H B A 10.5 10.5 5.1 9.5 26 1 5H9 depth 4 +0.030 0 6 NN-M6 x 1 thread depth 12 B A 5H9 depth 4 +0.030 0 Section AA Section BB GA HA (mm) Model F 35 35 35
Dryer Capacity Model A B C D E F B IN PUT IDF1D-1 to 11C-1 IDU3D-1 to 11C-1 4.2 x 7 (Long hole) Single phase Single turn 110VAC (50Hz) 110 to 120VAC (60Hz) 100VAC (50Hz) 100 to 110VAC (60Hz) 500VA 78 94 100 64 75 1.5 IDF-TR500-1 E D 4-F IDF15C-1 IDU15C-1 4.2 x 9 (Long hole) Input cord 2m 1kVA 104 122 134 75 114 4 IDF-TR1000-1 IDF-TR -2 C A OUT PUT Weight (kg) Primary voltage Secondary voltage
2, 3, 7 How to Order MSQB A F9B 1 Basic Type Number of auto switches 2 pcs. 1 pc. n pcs.
As a guide, turn 90 from the position where it comes to feel tight. Set the tightening torque of a hexagon socket head set screw (M4 x 0.7) to be 1 to 1.2 Nm. 1. Fix it to the detecting position with a set screw by installing a mounting bracket in cylinder tie-rod and letting the bottom surface of a mounting bracket contact the cylinder tube firmly. (Use hexagon wrench) 2.
As a guide, turn 90 from the position where it comes to feel tight. Set the tightening torque of a hexagon socket head set screw (M4 x 0.7) to be 1 to 1.2 Nm. 1. Fix it to the detecting position with a set screw by installing a mounting bracket in cylinder tie-rod and letting the bottom surface of a mounting bracket contact the cylinder tube firmly. (Use hexagon wrench) 2.
As a guide, turn 90 from the position where it comes to feel tight. Set the tightening torque of a hexagon socket head set screw (M4 x 0.7) to be 1 to 1.2 Nm. 1. Fix it to the detecting position with a set screw by installing a mounting bracket in cylinder tie-rod and letting the bottom surface of a mounting bracket contact the cylinder tube firmly. (Use hexagon wrench) 2.
Combination description Holder mounting bracket Spacer length X417 X416 1 2 1 1 1 1 1 A, L, AS, LS X416 on one side X416 on both sides X416 on one side, X417 on the other side X416 on A unit side X416 on L unit side X416 on A unit side, X417 on the other side X416 on L unit side, X417 on the other side X417 on one side X417 on both sides X417 on A unit side X417 on L unit side Nil W Z A L
15 20 A A L1 L2 4 Manual override + + + + 10 10 3.2 63.3 [65.5] 15.3 32 111.5 [115.9] 17 7.5 (4.4) 12.5 1 98.6[103] 16 A A A A A A R P R P 31.2 31.5 64.1 [66.3] 36.5 B B B B B B 65.3 17 50.5 70.3 2-4.5 (For mounting) + + + + + + Triangle mark 1/8 (P, R port) (Pitch) P = 12.5 18.5 1/8 (P, R port) (Station n) (Station 1) (Light/surge voltage suppressor) Applicable connector: 26 pins MIL type
or less 0.5 A or less 0.5 A or less Power supply fuse 3 A 1 A 1 A Two-time Hitting Function Interrupt Operation Function A two-time hitting function has been adopted to improve the bag filter dusting efficiency.
Grade 4 M4.5 ISO class 6 10 M5.5 ISO class 7 0.1 0.5 1 1 M6.5 ISO class 8 Particle diameter (mm) Selection procedure (1) Required clean room cleanliness? Class M2.5 or Class M3.5 or Class M4.5? Diagram 1 Air flow (2) Air flow to the workpiece (Refer to Diagram 1.) Workpiece A The air flow is blocked before it reaches the workpiece.