SMC Corporation of America
Elite Part Number Search
Search Results "AL40-02B-38-A"

* 1015 10 1% 2162 LCD * -8No.PS-OMV0008CN-E ISE70G 02 L2 M 3 Y K T ISE70G 0~1 MPa ISE75G 0~2 MPa ISE76G 0~5 MPa ISE77G 0~10 MPa ISE78G 0~16 MPa 2 A A B B 02 Rc1/4 N02 NPT1/4 F02 G1/4 :ISO1179-1 1 M12 5m M12 5m T S : L IO-Link/1+2 NPNorPNP L2 1 M SI2 1 2kPaMPa / A ZS-50-A M46 2 B ZS-50-B M46 2 ZS-48-A ZS-31-B 5 m M12 ZS-31-C 5 m -9No.PS-OMV0008CN-E M12 4 24 OUT1 IO-Link

Flow Characteristics With DIN terminal block With terminal block Port size Flow characteristics 2 3 (A R) b Cv C [dm 3/(sbar)] 1 2 (P A) b Cv C [dm 3/(sbar)] 26 38 0.38 0.30 7.0 9.8 27 38 0.37 0.32 7.4 9.8 27 40 0.36 0.22 7.3 9.8 25 40 0.37 0.20 6.8 9.6 2 1 (A P) b Cv C [dm 3/(sbar)] 3 2 (R A) b Cv C [dm 3/(sbar)] 1/2 3/4 Port size Effective area (mm2) 2 3 (A R) 1 2 (P A) 235

V Assy ZB1-VPN3--A KJ-C1 ZB1-FE3-A 30m 10 1 ZB1-SE1-A 10 1 Assy ZB1-PS-A Assy ZB1-ZS-A Assy ZZB26 - No.ZB-OM00301 () ZB1-VQ110U() ZB1-VQ110LZB03 ZB04 ZB05 ZB06 ZB00 () ZB1-VQ120U() ZB1-VQ110 K1 N.C. N.C. () () () () () () () () () () J1 N.C.

(ZS-24-A/ZS-35-A) B *(ZS-24-D) C D + F02 ISO228-1 1 *1 L M SI*2 P (psi)*1 1 2 ISE80H: MPa MPa kpa N NPN1 P PNP1 A NPN2 B PNP2 R NPN2+/ T PNP2+/ S NPN2+/ V PNP2+/ / ZS-24-A ZS-24-D ZS-35-A ZS-35-C ZS-35-B ZS-35-F ZS-35-E + -9No.PS-OMM0002CN-F LCD (UP) (SET) ) (DOWN) () LCD 4 (UP) ON/OFF (DOWN) ON/OFF (SET) -10No.PS-OMM0002CN-F 2 ON/OFF 2 7 "8"7 "-"()7 digit()

A part B part Procedure Calculation Calculation example 1. Check the operating conditions, dimensions of attachment, etc. Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.

Block off the heat with a cover, etc. 5. Do not use in locations where static electric charges will be a problem. Please consult with SMC regarding use in this kind of environment. 6. Do not use in locations where spatter occurs. There is a danger of spatter causing a fire. Please consult with SMC regarding use in this kind of environment. 15-17-8

6 r A A A A !4 i u q i !4 r y t y !2 o !5 r u t q !5 e i o !2 r Component Parts No. Description Material Note No. Description Material Note Body A O-ring PBT NBR q !3 Elbow body O-ring PBT NBR w !4 Body B O-ring Electroless nickel plated Brass NBR e !5 Body B O-ring Electroless nickel plated Brass NBR r !6 Needle Spacer Electroless nickel plated Brass POM (2) t !

(A-B)/4 n_1(n_2)=B+(A-B)/4 A= H_1(H_2)=(A-B)/2 H_1(H_2)=(A-B)/2 B= UPDOWN1 -36No.PS-OMV0003CN-G [F 6] 5R.D. <> UPDOWN[F 6] SET UP DOWN SET [F 6] -37No.PS-OMV0003CN-G [F10] 39 <> UPDOWN[F10] SET UP DOWN 2 OFF (OUT1) (OUT2) [dUAL]2 SET () [LinE] SET () () 40 () UP DOWN () SET , (SET ) SET () [dUAL]2 SET () AbY(Z) 40 () 019 ( ) UP DOWN / () SET 1 () SET SET [F10

L plug connector: VQD1151l-lL-M5 M plug connector: VQD1151l-lM-M5 5 5 5.5 SY 4(A) 2(B) SYJ SX VK VZ Lead wire length: 300mm Direct manual override Light 27 VF VFR SMC 17.6 11.2 3(R) VP7 9 3 2-3.5 Mounting hole 10.9 9.1 VP4 5.5 VQ VQ4 33.5 38 37 12 28.5 VQZ 1(P) 1(P) VQD 4-M5 X 0.8 5.5 (P, A, B, R port) 13 VZS L plug connector (L) 49 50.5 VFS M plug connector (M) VS VS7 1.13-7 Series VQD1000

A bumper at the end of the bumper bolt is replaceable. In case a missing bumper, or a bumper has a permanent setting, use the following part numbers for ordering. 3. Secure the plate before mounting the load. Load mounting without securing the plate may cause galling of the piston rod, leading to particle generation.

A A Solid state auto switch D-M9B, D-M9N Reed auto switch D-A93 (mm) (mm) Stroke (mm) 20 41 29 47 35 Stroke (mm) 20 45 25 51 31 Auto switch operating range Auto switch operating range 15 40.5 20.5 Model Model 25 50.5 30.5 30 59 39 10 35 15 25 46.5 34.5 30 55 43 10 31 19 15 36.5 24.5 A B A B A B A B A B A B 11-/22-MXP10 11-/22-MXP10 11-/22-MXP12 11-/22-MXP12 3 5 11-/22-

- (2-3-1) LECPA . 32 (2-3-2) LECPA . 32 (2-3-3) LECPA . 34 5.4 .36 5.4.1 .36 (1) .36 (2) .38 5.4.2 .40 (1) .40 (2) .41 6. .42 6.1 .42 (1) .42 (2) .44 (2-1) LECPLECA .44 (2-2) LECPLECA .45 (2-3) LECPA .46 6.2 .47 (1) .47 (2) .47 (3) .48 (4) .50 (5) .51 (6) .52 (7) .54 (8) .54 6.3 .56 (1) .56 (2) .56 (2-1) .56 (2-2) .56 (3) .57 (3-1) .57 (3-1-a) TB Ver1.**. 57 (3-1-b) TB Ver2.**. 58 (3-2) .59

30 55 43 10 31 19 15 36.5 24.5 A B A B A B A B A B A B 11-/22-MXP10 11-/22-MXP10 3 5 11-/22-MXP12 11-/22-MXP12 11-/22-MXP16 11-/22-MXP16 99 Air slide table MXP/MXPJ6 11221122Dimensions / MXPJ6 5 C 11-/22-MXPJ6-5 Depth 2.5 2.5 7 H 5 10.05 3 3.5 4M3 x 0.5 depth 3 +0.030 0 D B 16.5 3.5 18 14 13 20 6 +0.030 0 Depth 2.5 2.5 6 E 5 2-M4 x 0.7 Piping port F QL 6 13.5 Prepared hole diameter 3.3

Bowl a-ring NBR 11297 111512 111636 4D Valve a-ring NBR 1349247 131544 131645 CB a-ring NBR JIS B2401P5 JIS B240 1P5 Note) Bowl assembly of AW3001 and AW4001 are f,tted with a bowl guard(SPC) as standard. 8 Series AW Dimensions Panel mounting hole AW2001 ~ A W2001 : Max.3.5t 5 34 1 .4

Windows Edition Operating environment Model: LC1-1-W1 A model with a Pentium 75MHz or faster CPU, and able to fully operate Windows 95. Computer Windows 95 16MB or more 5MB of disk space required OS Memory Disk drive Windows is a registered trade mark of the Microsoft Corporation. Pentium is a domestic trade mark of the Intel Corporation.

(A-B)/4 n_1=B+(A-B)/4 A= H_1=(A-B)/2 H_1=(A-B)/2 B= OUT2P_1n_1H_1P_2n_2H_2 1 -39No.PS-OMU0005CN-C [F 5] FUNC /FUNC 0 57[F97] <> [F 5] FUNC FUNC FUNC [ASin] [CoPY]( ) [AoUt] -40No.PS-OMU0005CN-C OUT1 OUT2 OUT1 OUT2 [F 5] FUNC 5ms ASin ooo1 C_5 5ms ASino.r1 ( ) C_5(44 ) C_5 -105.0105.0 kPa -210210.0 kPa -0.1051.050 MPa -1.1551.155 MPa 10.0-105.0 kPa -115.0115.0 kPa -41No.PS-OMU0005CN-C

(A-B)/4 n_1=B+(A-B)/4 A= H_1=(A-B)/2 H_1=(A-B)/2 B= OUT2P_1n_1H_1P_2n_2H_2 1 -40No.PS-OMU0008CN-D [F 5] FUNC /FUNC 0 58[F97] <> [F 5] FUNC FUNC FUNC [ASin]( ) [AoUt]( ) [CoPY]( ) -41No.PS-OMU0008CN-D OUT1 OUT2 OUT1 OUT2 [F 5] FUNC 5ms ASin ooo1 C_5 5ms ASin o.r1 ( ) C_5(45 ) C_5 -105.0105.0 kPa -210210.0 kPa 1 MPa -0.1051.050 MPa -1.1551.155 MPa 2 MPa -0.1052.100 MPa -2.202.205

Enclosure Note) Impact resistance: No malfunction when tested with a drop tester in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states.