(between FE and all accessible terminals) Insulation resistance 10 M ohm or more (500 VDC is given between FE and all accessible terminals) Ambient temperature Operation: -10 C to 50 C Storage: -20 C to 60 C Ambient humidity 35% to 85% RH (non-condensing) 10 Hz to 57 Hz (constant amplitude) 0.75 mm 57 Hz to 150 Hz (constant acceleration) 49 m/s2 2 hours for each direction X, Y and Z (complies
M D2 L A D1 M5 X 0.8 M6 X 1.0 36.5 KSH04-M5 KSH04-M6 KSH04-01S KSH06-M5 KSH06-M6 KSH06-01S KSH06-02S KSH08-01S KSH08-02S KSH08-03S KSH10-02S KSH10-03S KSH10-04S KSH12-03S KSH12-04S 9 12 37 33 8 16 10.4 2.5 4.0 4.0 4 38 37.5 38 39.5 42.5 44 47 48 54 55 57.5 57 60 14 34 33.5 34 35.5 36.5 40 41 41.5 48 48.5 49.5 50.5 52 12 1 8 M5 X 0.8 M6 X 1.0 2.5 3 4.0 4.0 5.6 5.6 12 8 6 17 14 12.8 1 8 1 4
Thomas Liquid Diaphragm Pump Flow Rate: 150 ml / min , 150 ml / min, Max Pressure: 30 m H20 , 30 m H20, Max Suction: 5 m H20 , 5 m H20, Voltage (DC): 24, DC Motor Type: Standard, Item Dimensions: Length: 2.05 in / 52 mm Width: .91 in / 23 mm Height: 1.46 in / 37 mm , Length: 2.05 in / 52 mm, Width: .91 in / 23 mm, Height: 1.46 in / 37 mm, Net
Thomas Liquid Diaphragm Pump Flow Rate: 180 ml / min , 180 ml / min, Max Pressure: 30 m H20 , 30 m H20, Max Suction: 6 m H20 , 6 m H20, Voltage (DC): 12, DC Motor Type: Standard, Item Dimensions: Length: 2.05 in / 52 mm Width: .91 in / 23 mm Height: 1.46 in / 37 mm , Length: 2.05 in / 52 mm, Width: .91 in / 23 mm, Height: 1.46 in / 37 mm, Net
Thomas Liquid Diaphragm Pump Flow Rate: 180 ml / min , 180 ml / min, Max Pressure: 30 m H20 , 30 m H20, Max Suction: 6 m H20 , 6 m H20, Voltage (DC): 24, DC Motor Type: Standard, Item Dimensions: Length: 2.05 in / 52 mm Width: .91 in / 23 mm Height: 1.46 in / 37 mm , Length: 2.05 in / 52 mm, Width: .91 in / 23 mm, Height: 1.46 in / 37 mm, Net
Thomas Liquid Diaphragm Pump Flow Rate: 150 ml / min , 150 ml / min, Max Pressure: 30 m H20 , 30 m H20, Max Suction: 5 m H20 , 5 m H20, Voltage (DC): 24, DC Motor Type: Low Cost, Item Dimensions: Length: 2.05 in / 52 mm Width: .91 in / 23 mm Height: 1.46 in / 37 mm , Length: 2.05 in / 52 mm, Width: .91 in / 23 mm, Height: 1.46 in / 37 mm, Net
Thomas Liquid Diaphragm Pump Flow Rate: 150 ml / min , 150 ml / min, Max Pressure: 30 m H20 , 30 m H20, Max Suction: 5 m H20 , 5 m H20, Voltage (DC): 12, DC Motor Type: Standard, Item Dimensions: Length: 2.05 in / 52 mm Width: .91 in / 23 mm Height: 1.46 in / 37 mm , Length: 2.05 in / 52 mm, Width: .91 in / 23 mm, Height: 1.46 in / 37 mm, Net
Thomas Liquid Diaphragm Pump Flow Rate: 180 ml / min , 180 ml / min, Max Pressure: 30 m H20 , 30 m H20, Max Suction: 6 m H20 , 6 m H20, Voltage (DC): 24, DC Motor Type: Low Cost, Item Dimensions: Length: 2.05 in / 52 mm Width: .91 in / 23 mm Height: 1.46 in / 37 mm , Length: 2.05 in / 52 mm, Width: .91 in / 23 mm, Height: 1.46 in / 37 mm, Net
Thomas Liquid Diaphragm Pump Flow Rate: 180 ml / min , 180 ml / min, Max Pressure: 30 m H20 , 30 m H20, Max Suction: 6 m H20 , 6 m H20, Voltage (DC): 12, DC Motor Type: Low Cost, Item Dimensions: Length: 2.05 in / 52 mm Width: .91 in / 23 mm Height: 1.46 in / 37 mm , Length: 2.05 in / 52 mm, Width: .91 in / 23 mm, Height: 1.46 in / 37 mm, Net
Thomas Liquid Diaphragm Pump Flow Rate: 150 ml / min , 150 ml / min, Max Pressure: 30 m H20 , 30 m H20, Max Suction: 5 m H20 , 5 m H20, Voltage (DC): 12, DC Motor Type: Low Cost, Item Dimensions: Length: 2.05 in / 52 mm Width: .91 in / 23 mm Height: 1.46 in / 37 mm , Length: 2.05 in / 52 mm, Width: .91 in / 23 mm, Height: 1.46 in / 37 mm, Net
(mm) I 9 11 Model MHS2-50D MHS2-63D G 37.5 44 FZ 6 7 FX 31 38 FY 28 34.5 EC 22 30 EO 34 46 DC 70 86 DO 82 102 M 2 3 B 70 86 K 10 11 AC 3 4 J 24 28 AA 55 66 AB 52 62 NA 18 24 L 4H9 6H9 NB 10h9 12h9 CA 9 12 CB 20 22 0 -0.036 0 -0.043 +0.030 0 +0.030 0 Model MHS2-50D MHS2-63D SC 12 14 RB 34 38 O 5 5.5 4H9 5H9 VA Q 14 17 RA 52 66 VB 4 5 WA WB 2 2.5 XA XB 4 5 YC 7 7.5 +0.030 0 +0.030 0 +0.074
M Element Replacement Procedure Body Model A B C D E F G H I J K L M N Size ZFB100-04 ZFB100-06 ZFB200-06 ZFB200-08 ZFB300-08 ZFB300-10 12.8 4 6 53 54 8.5 14.4 15.5 50 15 17.5 24 12.5 26 22.5 48 Metric size Inch size 15.2 6 8 9.5 16.6 17.5 61 16 19.5 27 13.5 28 65 24.5 52 Collar part arrow 57 8 10 69.5 70 18.5 11 18 21.5 65 17 21 29.5 14.5 30 27 Transparent cover 3 16 1 4 " 1 4 " 3 8 " 1
(EX245-EA2-1) No. 1 SI ON/OFF 2 IO-Link IO-Link 3 4 5 SI 6 . 1-1 12 No.EX-OMW0014CN-A 2. . 2-1 EX245 DC24 V 1 msec IP65(,) (IEC 60529 ) CE/UKCA UL(CSA) RoHS EN505812012 AC500 V1 FE 10 M -FE DC500 V -1050 -2060 35%85%RH 1057 Hz0.75 mm p-p 57150 Hz49 m/s 2 XYZ 2 (IEC60068-2-6) 147 m/s 2 XYZ 3 () (IEC60068-2-27) 13 No.EX-OMW0014CN-A 3. 3.1. 6 2M5( = 1.5 Nm
PNP 1~5 V F PNP 4~20 mA G NPN H PNP J 1~5 V 1~5 V K 4~20 mA 4~20 mA OUT2 C (1) T V + (2m) N M L/min L G gal/min gal F gal/min gal J L/min L GFJ : 1[L/min]0.2642[gal/min] 1[gal/min]3.785[L/min] []=9/5[]+32 15 V PF3W5--1(T) -9No.PF-OMN0011CN-C C (1 ) T V -10No.PF-OMN0011CN-C / ZS-26-B ZS-26-C ZS-26-01 ZS-40-W 2 m (e-con) ZS-28-CA-4 1 ZS-40-Y 10 -11No.PF-OMN0011CN-C
Do not use a cable longer than 10 m. Wire the DC (-) line (blue) as close as possible to the power supply.
Figure 5-52 Initial Setting screen 1 4. With the use of the arrow keys([],[]), Move the cursor to Initial Setting screen 3. Figure 5-53 Initial Setting screen 3 5.4 Examples of System Operation HRZ Series 5-40 HRX-OM-X010 Chapter 5 System Operation 5. With the use of the arrow keys([],[]), move the cursor toPUMP IVand press the [ENT]key.
Length of communication cable for RS-485 shall be limited to around 500[m] in total, and that for RS232C shall be 15[m].
LEC6 DC24 0V Shutdown is lifted Switch Ry Stop Switch Gateway EMG + Surge suppressor Ry Unit EMG Power supply plug (1st. unit) BK RLS EMG Ry C 24V Controller input power 24V 0V 0V M 24V Power supply plug (2nd. unit) BK RLS EMG Ry C 24V Controller input power 24V 0V 0V M 24V Power supply plug (3rd. unit) BK RLS EMG Ry C 24V Controller input power 24V 0V 0V M 24V Caution When the stop signal
LEC6 DC24 0V Shutdown is lifted Switch Ry Stop Switch Gateway EMG + Surge suppressor Ry Unit EMG Power supply plug (1st. unit) BK RLS EMG Ry C 24V Controller input power 24V 0V 0V M 24V Power supply plug (2nd. unit) BK RLS EMG Ry C 24V Controller input power 24V 0V 0V M 24V Power supply plug (3rd. unit) BK RLS EMG Ry C 24V Controller input power 24V 0V 0V M 24V Caution When the stop signal
Lubrication Not required Mounting orientation Unrestricted 300/50 Note 2) Impact/Vibration resistance (m/s2) Note 1) In the case of single type, be certain that pressure within operating pressure range be supplied to supply port, because return pressure is introduced from supply port {1(P)} for activation.