Body Size: 50, Thread: N (NPT), Port: 06 (3/4), Option: CE (C + E), Attachment: TV (T + V), Semi-Standard 1: Standard, Semi-Standard 2: RZ (R + Z)
Body Size: 50, Thread: Rc, Port: 06 (3/4), Option: C [Float Type Auto Drain (N.C.)], Attachment: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 50, Thread: N (NPT), Port: 06 (3/4), Option: Standard, Attachment: S (Pressure Switch), Semi-Standard 1: 6 (Nylon Bowl), Semi-Standard 2: RZ (R + Z)
Body Size: 40, Thread: Rc, Port: 06 (3/4), Option: CE (C + E), Attachment: Standard, Semi-Standard 1: 8 (Metal Bowl w/Level Gauge), Semi-Standard 2: Standard
Body Size: 40, Thread: N (NPT), Port: 06 (3/4), Option: Standard, Attachment: S (Pressure Switch), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: NZ (N + Z)
Body Size: 3 (3/8), Type: 3 (Universal), Control Type: 0 (Meter-out), Thread: N (NPT), Port Size: 02 (1/4), Applicable Tubing: 06 (ø6), Seal Method: None
Body Size: 3 (3/8), Type: 3 (Universal), Control Type: 1 (Meter-in), Thread: N (NPT), Port Size: 03 (3/8, Applicable Tubing: 06 (ø6), Seal Method: None
Body Size: 3 (3/8), Type: 2 (Elbow), Control Type: 0 (Meter-out), Thread: N (NPT), Port Size: 02 (1/4), Applicable Tubing: 06 (ø6), Seal Method: None
Body Size: 3 (3/8), Type: 2 (Elbow), Control Type: 1 (Meter-in), Thread: N (NPT), Port Size: 02 (1/4), Applicable Tubing: 06 (ø6), Seal Method: None
Body Size: 3 (3/8), Type: 2 (Elbow), Control Type: 0 (Meter-out), Thread: N (NPT), Port Size: 03 (3/8, Applicable Tubing: 06 (ø6), Seal Method: None
Body Size: 3 (3/8), Type: 2 (Elbow), Control Type: 0 (Meter-out), Thread: G (G), Port Size: 03 (3/8, Applicable Tubing: 06 (ø6), Seal Method: None
Body Size: 3 (3/8), Type: 3 (Universal), Control Type: 0 (Meter-out), Thread: G (G), Port Size: 03 (3/8, Applicable Tubing: 06 (ø6), Seal Method: None
Body Size: 3 (3/8), Type: 2 (Elbow), Control Type: 0 (Meter-out), Thread: G (G), Port Size: 02 (1/4), Applicable Tubing: 06 (ø6), Seal Method: None
Body Size: 3 (3/8), Type: 2 (Elbow), Control Type: 1 (Meter-in), Thread: N (NPT), Port Size: 03 (3/8, Applicable Tubing: 06 (ø6), Seal Method: None
Body Size: 3 (3/8), Type: 2 (Elbow), Control Type: 1 (Meter-in), Thread: G (G), Port Size: 03 (3/8, Applicable Tubing: 06 (ø6), Seal Method: None
Body Size: 3 (3/8), Type: 3 (Universal), Control Type: 0 (Meter-out), Thread: N (NPT), Port Size: 03 (3/8, Applicable Tubing: 06 (ø6), Seal Method: None
Body Size: 3 (3/8), Type: 3 (Universal), Control Type: 0 (Meter-out), Thread: G (G), Port Size: 02 (1/4), Applicable Tubing: 06 (ø6), Seal Method: None
Body Size: 40, Thread: N (NPT), Port Size: 06 (3/4), Option: Standard, Attachment: Standard, Semi-Standard 1: 6 (Nylon Bowl), Semi-Standard 2: NRZ (N + R + Z)
Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: None, Port Size: 06 (3/4), Thread: F (G), Passage: A (Normally Closed)
Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: None, Port Size: 06 (3/4), Thread: N (NPT), Passage: A (Normally Closed)