(increment of 1 sec.), 20 sec., 30 sec., 40 sec., 50 sec. and 60 sec.
The slant angle of each rope should be 60 degrees or less. Never lay the product on its side. The compressor oil will leak in to the refrigerant piping, which may cause early failure of the compressor. Drain the residual fluid from the piping as much as possible to prevent any spillage.
Thermostat working temp. : 60+/-5 C (at radiating water side) Thermostat ERR14 Alarm 90+/-5 C (at recirculating fluid side) After alarm occurrence : The unit (temp. control, pump) stop.
. -3No.LEY*-OMZ0010 1Rod type / LEY Series 1.1 Specification Model LEY 25E-X8 LEY 32E-X8 LEY 40E-X8 (3000 [mm/s2]) 20 40 60 30 45 60 50 60 80 Horizontal Work load [kg] Note1) (2000 [mm/s2]) 30 55 70 40 60 80 60 70 90 Vertical (3000 [mm/s2]) 7 15 29 10 21 42 12 26 52 Pushing force [N] Note2) Note 3) Note 4) 63 to 122 126 to 238 232 to 452 80 to 189 156 to 370 296 to 707 132 to 283 266 to 553
VXF21A VXF22A VXF23A VXF24A VXF27B VXF28B VXF25(A,B) VXF26(A,B, C,D) Product number Orifice size mm 22 28 44 53 70 80 90 100 Air Fluid Minimum operating pressure Maximum operating pressure MPa 0.03 0.1 MPa 0.7 Fluid temperature -10 (Non-freezing) to 60 Ambient temperature -10 to 60 Coil insulation type Class B Enclosure IP65 Alloable voltage fiuctuation 10% of rated voltage AC VA 10 7
Operation/ Shutdown Fig 3.8 Timing chart of signals Reset a counter of Abnormal stop 10 min Abnormal stop 4 (1) The abnormal stop will be automatically reset until 4 times within 60 minutes, but the 5th time will not be automatically reset in this case, reset Automatic return 60 min Abnormal stop 3 Abnormal stop 2 Abnormal stop 1 Manual Abnormal stop 5 (2) When the alarm is generated by the
.* Standard dew point -60oC : about 60 min.* * This time can be shortened as described below. 1) Provide a valve on the outlet side of the membrane air dryer. 2) Supply air with the valve closed so that only purge air flows through the membrane air dryer. 3) After 15 minutes or more, open the valve and let air flow to the outlet side equipment. Selection Caution a.
), ACMA (Australia/New Zealand), IMDA (Singapore), SIRIM (Malaysia), ENACOM (Argentine), ICASA (South Africa), NCT (Philippines), FAC (Russia), CoC (Ukraine), ANRT (Morocco) -67No.EX-OMU0028-D Models EX600-WSV1 EX600-WSV2 Enclosure rating Conforms to IP67 (with manifold assembled) Ambient temperature (Operating temperature) -10 to +50 oC Ambient temperature (storage temperature) -20 to +60
Order 42 Summary of Product parts 42 Mounting and Installation 43 Installation 43 Separate power supply 46 LED Display and Settings 47 Specification 48 Specifications 48 Dimensions 49 1 No.EX-OMS0014-A Input unit Model Indication and How to Order 50 Summary of Product parts 50 Mounting and Installation 51 Installation 51 Wiring 52 LED Display 58 Specification 59 Specifications 59 Dimensions 60
), ACMA (Australia/New Zealand), IMDA (Singapore), SIRIM (Malaysia), ENACOM (Argentine), ICASA (South Africa), NCT (Philippines), FAC (Russia), CoC (Ukraine), ANRT (Morocco) -78No.EX-OMW0006-D Models EX600-WSV1 EX600-WSV2 Enclosure rating Conforms to IP67 (with manifold assembled) Ambient temperature (Operating temperature) -10 to +50 oC Ambient temperature (storage temperature) -20 to +60
Port Layout 60 11. Exhaust/Flow Rate Characteristics 70 11.1. Ejector Exhaust Characteristics/Flow Rate Characteristics 70 11.2. Vacuum Pump System Flow Rate Characteristics 72 11.3. Vacuum Release Flow Rate Characteristics 72 12. Limitations of Use 74 13. Troubleshooting 76 -1No.
Model Motor size Set value of pushing force[%] LEPY6 LEPS6 Basic 70 to 100% LEPY10 LEPS10 Basic 50 to 100% Compact 60 to 100% 43 - a. Posn failed alarm is generated The product cannot reach a pushing start position due to variation in the width of workpieces. b. Pushing ALM alarm is generated The product is pushed back from a pushing start position after starting to push. c.
If operated beyond the limiting ranges, excessive impact will occur and this may cause damage to equipment. 2.00 25 1.50 20 1.00 0.50 0.00 20 30 40 50 60 70 80 90 100 Stroke (mm) Cushion Needle Adjustment Caution : Operating pressure 0.5MPa : Operating pressure 0.4MPa Graph 1 1.
50 Mounting hole IR300-0 IR2120-02 36 2 Bracket (optional) 30 82 Mounting hole Pressure gauge (optional) 60 2.3 48 Bracket (optional) 5.5 9.5 M5 depth 7 75 83 Approx. 119 18 1 1 SMC IN Bleed Pressure gauge (optional) Exhaust SUP(1) OUT(2) OUT 43 Approx. 60 50 50 2-Rc(PT) 1/4 Port size Rc(PT) 1/8 Pressure gauge port M6 x P0.5 15.5 9 82 60 IR3120-0 Mounting hole 48 2.3 76 Approx. 148 22
Output deviation (%F.S.) 0.5 0.5 Out VE 40 0 0 Return VY G 60 0.5 0.5 AL 80 1.0 1 0 2 4 6 8 10 0 25 50 75 100 0 25 50 75 100 Input signal (%F.S.) Input signal (%F.S.)
80 100 120 140 0 10 20 30 40 50 60 70 80 90 100 Flow rate l/min (ANR) Flow rate l/min (ANR) SRP1-01 SRP1101-01 Conditions/Upstream pressure: 0.5MPa Conditions/Upstream pressure: 0.7MPa 0.25 0.50 0.20 0.40 Downstream pressure MPa Downstream pressure MPa 0.15 0.30 0.10 0.20 0.05 0.10 0.00 0.00 0 20 40 60 80 100 120 140 160 180 200 0 20 40 60 80 100 120 140 Flow rate l/min (ANR) Flow rate l
80 100 120 140 0 10 20 30 40 50 60 70 80 90 100 Flow rate l/min (ANR) Flow rate l/min (ANR) SRP1-01 SRP1101-01 Conditions/Upstream pressure: 0.5MPa Conditions/Upstream pressure: 0.7MPa 0.25 0.50 0.20 0.40 Downstream pressure MPa Downstream pressure MPa 0.15 0.30 0.10 0.20 0.05 0.10 0.00 0.00 0 20 40 60 80 100 120 140 160 180 200 0 20 40 60 80 100 120 140 Flow rate l/min (ANR) Flow rate l
Hz 00 01 Without sub-plate Rc 1/8 (6A) Accessory 2 200 VAC, 50/60 Hz Without sub-plate (For manifold) 4 Indicator light (DC is possible only for DL.)
Hz 200 VAC 50/60 Hz 100 VAC 50/60 Hz Symbol A: Non-locking push type A (projecting) N.C. 0.5 MPa N.O. 1 MPa N.C. 1 MPa 4 1 6A 8A 10A 10A 15A 20A 25A 32A 1 8 1 4 3 8 3 8 1 2 3 4 220 VAC 50/60 Hz Valve size 1 7 5 6 24 VDC 12 VDC B: Slotted locking type B (tool required) 7 240 VAC 50/60 Hz 15 (11) 2 Semi-standard For other rated voltages, please consult with SMC. 20 (14) 3 25 (16) 4 1 1
NCY3B10 0.10 NCY3B6 0.05 0.00 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Stroke (inch) The above deflection data represent values at the time when the external sliding part moves to the middle of the stroke. Vertical Operation The load should be guided by a ball type bearing (linear guide, etc.).