(Equivalent lead (8)Cable length * [m] (7)Cable type (9)Driver type Power supply Without cable Nil Without cable Nil Compatible drivers voltage [V] Standard cable 3 3 S R Nil Without driver Robotic cable (Flexible cable) 5 5 200 to 230 200 to 230 M2 LECYM2-V A 10 U2 LECYU2-V C 20 * The length of the motor and encoder cables are the same.
Maximum Speeds for Each Transfer Load Unit (mm/s) Transfer load (kg) 15 20 25 30 1000 1000 930 740 600 500 Model Note LG1H202PC-500-F LG1H202PC-600-F LG1H202PC-700-F LG1H202PC-800-F LG1H202PC-900-F LG1H202PC-1000-F 700 700 600 600 500 500 500 500 500 500 500 500 500 500 500 500 500 500 Power supply: 100/110(V)AC 10% Compatible controller: LC1-12HC1Power supply: 200/220(V)AC 10% Compatible
AS 0 0.1 0.15 0.2 0.25 0.3 Return stroke pressure (MPa) ASP ASN v v w w a a o o l l v v l l F F e e AQ ASV u u r r e e s s v v s s a a e e l l v v r r P P e e AK ASS ASR ASF Working stroke Working stroke Return stroke Return stroke Pressure valve Flow valve 15-16-1 2 Cuts air consumption by operating the return stroke at a reduced pressure.
Bore size Operating range Bore size mm (in) OUT () Blue [Black] 180 200 8 (0.3) 8 (0.3) Operating range l (mm) 10 Compact Cylinder Series CQ2 2 Colour Indicator Type Solid State Switches/Direct Mounting Type D-YNW(V), Y7PW(V), D-Y7BW(V) Auto Switch Specifications D-Y7W, D-Y7WV (with indicator light) D-Y7NW D-Y7NWV D-Y7PW D-Y7PWV D-Y7BW D-Y7BWV Auto switch model no.
(same side) 60 D-Y59A(B), Y69A(B) Y7P(V) 1 pc., 2 pcs. (different sides) 20 2 pcs. (same side) 70 D-Y7NW(V), Y7PW(V) Y7BW(V) Solid state switch 1 pc., 2 pcs. (different sides) 25 2 pcs. (same side) 70 D-Y7BAL 1pc., 2 pcs.
Brown Brown Load Load Switch 1 Switch 1 Blue Blue Brown Brown Switch 2 Switch 2 Blue Blue Load voltage at ON = Power supply voltage Internal voltage drop x 2 pcs. = 24 V 4 V x 2 pcs. = 16 V Load voltage at OFF = Leakage current x 2 pcs. x Load impedance = 1 mA x 2 pcs. x 3 k = 6 V Example: Power supply is 24 VDC Internal voltage drop in switch is 4 V. Example: Load impedance is 3 k.
Solenord side. .9 fi V f--'.--ry] f+r-q | r + r i | | t-?-!+-<-{ l r l tF)-)-+++--(lr{ I , _ ' I{ANIFOLD BLOCK PART NO. NO. PRESSURE CYLII{OEF " A & 8 " EXHAUST "EA & E8" SIDE aoTTor !OYTOT MSA 1010.02 Yes '/f t2) Yes MBA 10't r.02 11 Yes 't"et t ' l Z YE MAA 4210.02 t6 Y5 v." 11) v.' t2\ t " t2:l t ' l a STATX)flS 2 3 a 5 6 7 I t t0 -1 nm) 5 .
(v) Repeat (iii) to (v) until eight shifts have been performed. (vi) After the last eight shifts, exclusive OR the result of (vi) with the next 1-byte (2nd byte). (vii) The processes (iii) to (vii) are repeated to all the remaining bytes of the message (3rd byte to the last byte). (viii) The 2-byte data of the result of (viii) is the CRC value. (2) Calculation example e.g.)
PWR(V) PWR L ERR L RUN 1 2 If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system. Check the product regularly for proper operation. Otherwise malfunction can result, causing an accident.
Linked/N.C.), 3rd Selection Vacuum V Port: 8 (Vacuum, V Port: Ø8), 3rd Selection Quantity: 1, /: /, 4th Nominal Nozzle Size: 3 (ø1.2), 4th Selection Supply Valve and Release Valve: R ( Self-holding Release Valve Linked/N.C.), 4th Selection Vacuum V Port: 6 (Vacuum, V Port: Ø6), 4th Selection Quantity: 1
/N.C., 3rd Selection Vacuum V Port: Vacuum, V Port: Ø8, 3rd Selection Quantity: 4, /: -, 4th Nominal Nozzle Size: -, 4th Selection Supply Valve and Release Valve: -, 4th Selection Vacuum V Port: -, 4th Selection Quantity: -
Vacuum V Port: Vacuum, V Port: Ø8, 3rd Selection Quantity: 1, /: /, 4th Nominal Nozzle Size: ø1.2, 4th Selection Supply Valve and Release Valve: Self-holding Release Valve Linked/N.C., 4th Selection Vacuum V Port: Vacuum, V Port: Ø6, 4th Selection Quantity: 1
Maximum 30 V (NPN only), 80 mA, Residual voltage 1 V or less See the operation manual for information on how to set and on handling precautions. Output -43 Output -65 DC (+) DC (+) (Brown) (Brown) N.C.
Normally open Grommet, Conduit, DIN terminal, Other (Option) VNB01V VNB02V Grommet, Grommet terminal, Conduit terminal, DIN terminal Electrical entry 10 (P2) 12 (P1) Air operated Coil rated voltage (V) AC (50/60 Hz) 100 V, 200 V, other voltage (Option) 24 V, other voltage (Option) 15% to +10% of rated voltage Class B or equivalent (130C) DC 2 (B) 1 (A) 2 (B) 1 (A) Allowable voltage fluctuation
Note 2) Value on option V (Non-leak, Vacuum).
Insulation type Electrical entry Electrical option Class B G C D, T S Note) S L, Z 1 (100 V) 2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) 5 (24 V) 6 (12 V) AC DC Note) Surge voltage suppressor is attached in the middle of a lead wire. 17-3-72 3 The VX series will be revised shortly.
/N.C.), 3rd Selection Vacuum V Port: 6 (Vacuum, V Port: Ø6), 3rd Selection Quantity: 1, /: /, 4th Nominal Nozzle Size: 4 (ø1.5), 4th Selection Supply Valve and Release Valve: K (N.C./N.C.), 4th Selection Vacuum V Port: 6 (Vacuum, V Port: Ø6), 4th Selection Quantity: 1
The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple. PRESSURE SWITCH, ISE1-6. 3 SCREEN HI PRECISION DIG PRESS SWITCH. 26.00000 lb. N59.
The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple. PRESSURE SWITCH, ISE1-6. 3 SCREEN HI PRECISION DIG PRESS SWITCH. 71.00000 lb. N59.
The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, PRESSURE SWITCH, ISE1-6, N59, 73.00000 lb