SMC Corporation of America
Elite Part Number Search
Search Results "IS10M-60-1-D"

Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet, type D DIN connector, type Y DIN connector, SOFT START-UP VALVE, VALVE, SOFT START, 239, 0.80000 lb

Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet, type D DIN connector, type Y DIN connector, SOFT START-UP VALVE, VALVE, SOFT START, 237, 1.25000 lb

Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet, type D DIN connector, type Y DIN connector, SOFT START-UP VALVE, VALVE, SOFT START, 239, 1.25000 lb

Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet, type D DIN connector, type Y DIN connector, SOFT START-UP VALVE, VALVE, SOFT START, 239, 1.25000 lb

Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet, type D DIN connector, type Y DIN connector, PILOT VALVE ASSEMBLY, VALVE, SOFT START, 237, 0.06500 lb

Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet, type D DIN connector, type Y DIN connector, SOFT START-UP VALVE, VALVE, SOFT START, 239, 0.45000 lb

Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet, type D DIN connector, type Y DIN connector, SOFT START-UP VALVE, VALVE, SOFT START, 237, 1.25000 lb

Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet, type D DIN connector, type Y DIN connector, SOFT START-UP VALVE, VALVE, SOFT START, 239, 1.30000 lb

Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet, type D DIN connector, type Y DIN connector, SOFT START-UP VALVE, VALVE, SOFT START, 237, 0.43000 lb

Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet, type D DIN connector, type Y DIN connector, SOFT START-UP VALVE, VALVE, SOFT START, 239, 0.43000 lb

Model: 3 (SGC300), Valve Type: 2 (Normally Open), Seal Material: A (NBR), Pressure Range: 05 (0 to 0.5 MPa), Thread: N (NPT), Port Size: 20 (3/4), Pilot Valve: Y (0.35 W Type, V116), Voltage: 4 (220 VAC (230 VAC) 50/60 Hz), Electrical Entry: D (DIN Terminal), Surge Suppressor: Z (With Light and Surge Voltage Suppressor)

Type of Actuation: 2 (2 Position Double), Manifold Type: 60 (Body Ported Plug-in Cassette), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: WO (M8 Connector w/o Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: D (Push-turn Locking Slotted Style), A, B Port Size: N3 (5/32" One-touch Fitting)

Type of Actuation: 4 (3 Position Exhaust Center), Manifold Type: 60 (Body Ported Plug-in Cassette), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: LO (L Plug w/o Connector), Lead Wire Length: None, Surge Suppressor: None, Manual Override: D (Push-turn Locking Slotted Style), A, B Port Size: C4 (Body Ported ø4 One-touch Fiitting)

Type of Actuation: 5 (3 Position Pressure Center), Manifold Type: 60 (Body Ported Plug-in Cassette), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: D (Push-turn Locking Slotted Style), A, B Port Size: C4 (Body Ported ø4 One-touch

Material: SS400, Number of Arranged Elements: 83, Element Length: D [ℓ1000 (ℓ250 x 4)], Port Size: 60 [150 (6B)], Element Type: Sintered Metal, Bronze Material, Nominal Filtration Accuracy: 40 μm, Element Seal Material: NBR