The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Type of Mount Support: Basic type, Rod Tip Shape: Without thread, Custom-made Specifications: Fluororubber seal, Connector Type: -
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: M9P, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: M9P, Lead
Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.12 to 0.7, Specification: Built-in magnet, Auto Switches: M9NW, Lead
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: M9N, Lead
The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Type of Mount Support: Basic type, Rod Tip Shape: Without thread, Custom-made Specifications: Heat-resistant cylinder (150°C), Connector Type: -
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: Without cushion, Specification: Built-in
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: With cushions on both sides, Specification
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: With cushions on both sides, Specification
The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Type of Mount Support: Rod-end flange type, Rod Boot: None, Custom-made Specifications: None, Type: Non-lube, Energized push/pull: Retracted when energized, Solenoid valve: 2 position single, Solenoid valve voltage: 24 V DC, Lead wire electrical entry: DIN terminal
The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Type of Mount Support: Rod-end flange type, Rod Boot: None, Custom-made Specifications: None, Type: Non-lube, Energized push/pull: Retracted when energized, Solenoid valve: 2 position single, Solenoid valve voltage: 24 V DC, Lead wire electrical entry: DIN terminal
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Rubber cushion
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Rubber cushion
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard / Drip-Proof / Lubrication Free, Valve Type: 5-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Pressure Differential Return), Valve Positions: 2-Position Exhaust, Applicable Cylinder Diameter(Ø): 80 or Less, Pipe Port Type: [Rc (R)] Rc, Port Size
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard / Drip-Proof / Lubrication Free, Valve Type: 5-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Pressure Differential Return), Valve Positions: 2-Position Exhaust, Applicable Cylinder Diameter(Ø): 80 or Less, Pipe Port Type: G, Port Size: 1/8, Connecting
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard / Drip-Proof / Lubrication Free, Valve Type: 5-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Pressure Differential Return), Valve Positions: 2-Position Exhaust, Applicable Cylinder Diameter(Ø): 80 or Less, Pipe Port Type: NPT, Port Size: 1/8,
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard / Drip-Proof / Lubrication Free, Valve Type: 5-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Pressure Differential Return), Valve Positions: 2-Position Exhaust, Applicable Cylinder Diameter(Ø): 80 or Less, Pipe Port Type: NPTF, Port Size: 1/8