SMC Corporation of America
Elite Part Number Search
Search Results "25A-ISE20C-T-M-02-W"

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire,

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C01 (Rc1/8), Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

2 q w e r t y !1 !0 o i u Component Parts No.

How to Order Elements EJ T S 701 002 Element seal T PTFE Element classification EJ HEPO 2 Element size symbol Filtration accuracy (Filtration efficiency 99%) 701 801 901 For FGH100 For FGH200 For FGH300 002 004 006 013 2 m 4 m 6 m 13 m 70 HEPO 2 Element for FGH Series EJ Series Construction EJ701S, 801S, 901S FGD FGE FGG Reinforcement material FGA FGC FGF FGH FGH Filter media FQ1 FN EB ES

L R L R L R L R L R L R Glass q w e Stainless steel Stainless steel Cross recessed round head screw Brass Stainless steel r t Stub 3.8-2 ISA Specifications Fluid Dry air (Filtered through a 5m filter) Operating pressure range 0.05 to 0.2MPa Recommended pressure range 0.1 to 0.2MPa Detection zone 10 to 300 m Repeatability including temperature characteristics 10m (for 0 to 60C on the basis

Process Pump (Diaphragm Pump) PB Series Compact, large capacity diaphragm pump, suitable for transferring and collecting a wide range of fluids Compact, large capacity diaphragm pump, suitable for transferring and collecting a wide range of fluids o t p m s l a i PA z P e Built-in solenoid valve only RoHS Smaller, lighter, 25% reduction in volume Smaller, lighter, 25% reduction in volume

Lead wire length (m) Load voltage Auto switch part no.

Stations: 02 (2 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.

Stations: 02 (2 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: W (w/Flow Adj.

g n n k k ra oc c a o t r cl cl en nt er er e tm e m nt nt is us u t u w C 0 us o 90 k o c lo o C l dj C C 19 dj se c Cl 1 A k A A wi e w oc ge dj k A is oc k ng dj u wi e Cl an st us se ro ra m r ta t ot m r d at ti n e n io on e n e on nt e nt tio nd r r a a ti n n g ta e 5 9 g ta e 9 ro 5 ro m m u im u im ax M ax M Note) The drawing shows the rotation range of the positioning pin hole

(kg) Fig. (2) Overhang: Ln (mm), Correction Values for Moment Center Distance: An (mm) Pitch moment Yaw moment Roll moment W My Mr Mp W W W L3 A5 L1 A1 Adjusting bolt Static moment L2 A3 W MX Mp Mr My MTS W W W MY L1 A2 L3 A5 W L2 A4 CY Mey Note) No need to consider this load factor in the case of using perpendicularly in a vertical position.

IDX-OM-O004-B 2010 11 B2011 6 / Series IDF15E1-10 (-A,C,K,L,M,R,S,T) IDF15E1-20 (-A,C,K,L,M,R,T) URLhttp://www.smcworld.com/ English instruction manual can be downloaded from our URLhttp://www.smcworld.com/ 2011 SMC CORPORATION All Rights Reserved.

Load factor an Va Item Note CX W Examine W.

Connector type A B D M8-3 pins M8-4 pins M12-4 pins CJP Lead wire length S 0.5 (m)(1.64 ft) CJ2 M 1.0 (m)(3.28 ft) Auto Switch Mounting Bracket Part No.

Connector type A B D M8-3 pins M8-4 pins M12-4 pins CJP Lead wire length S 0.5 (m)(1.64 ft) CJ2 M 1.0 (m)(3.28 ft) Auto Switch Mounting Bracket Part No.