High flow rate: Cv factor 0.16 to 2.1 Smaller size: Single valve volume reduced by 15% (Class 3) Manifold length reduced by 18% (Class 3: 5 stations) (SMC comparison) Clip type Quick change coils Clip design makes coil replacement easy Flame resistance Coil size and weight reduced Conforms to UL94 V-0 New compact coil reduces the overall size and weight of the valve Volume 15% Weight 20%
H L1 L2 L3 L4 L5 L6 M1 M2 Q Model C D J E F G K 1(P)2(A) 2(A)3(R) 18 1(P) 2(A) 4 4 47.6 23.8 23.8 16.5 15.8 15.8 11 3.4 1.2 15 VHK-B1A 44.5 14.5 1 27 22 16.5 26 41 3.5 VHKl-04F-04F VHKl-06F-04F 18 6 4 6 41 48 48.6 24.3 23.7 16.5 3.5 16.8 15.8 11 5.1 1.2 15 16 VHK-B1A 44.5 14.5 1 27 22 16.5 26 VHKl-06F-06F 24.3 16.8 7.2 VHKl-08F-06F 18 8 6 8 41 50.5 52.4 26.2 24.3 16.5 3.5 18.7 16.8 11 9 1.2
Proper tightening torque Nm {kgfcm} Tightening torque for piping Connection threads M5 Rc(PT) 1/8 1.5 to 2 {15 to 20} 7 to 9 {71 to 92} Reference: Tightening into the M5 fitting threads After tightening by hand, tighten about 1/6 of a turn further using a tightening tool.
20, 25, 30 20, 25, 32 5, 10, 15, 20, 25, 30, 40, 50 TN TF R Rod piping/ Pad direct mounting 32 32 mm Note) In the case of rod piping (Q, R), TF (G1/8) is not available.
F.S. or less (adjustable) 2% F.S. or less (fixed) 0 to 15% F.S. or less (adjustable) 2% F.S. or less (fixed) Display 2-digit red LED Display accuracy 3 %F.S. 2 digits Output indicator light Lights up when output is ON (red LED).
fl 110+559120+559 Differenl 1 5 90 100 1 1 0 Same 90 100 1 1 0 Ditterent 15+5d!
Rotation Speed Range Model: 10, 15, 20O.O3 0.3 sec,/90' Model 300.04-0.3 sc,/90' lf a rotation soeed is used slower than 0.3sec/90", sticking may occur.
Port Thread Optional Specitications Standard specif icalion CE marked . 17. 18. 19 For manifold mountinq 2. 3. 15 CE marked DeviceNet comoatible 4,5.6.8. 14 CE marked 1 6 oreset tvoe 4 , 5 . 7 , 1 0 DeviceNet comoalible 5. 6, 8. 14 1 6 Dreset tvDe 5.7.10. 16 0 1s hiqh speed response Digital input type Reverse output 1 2 . 1 3 CE marked lar manilold mountinq 3. 15 CE rnarked 0.1s high speed
Seal VCW20-15-6 Note) Please order separately. 17-6-7 2/3 Port Process Valve Precautions 5 Be sure to read before handling. For detailed precautions on every series, refer to main text.
1 q t i 385 PF2D Series Dimensions: Remote Type Sensor Unit PF2D504-11/520-13 60 70 176 40 15 A Model PF2D504 PF2D520 9.52 12.7 62 52 42 A 4 x 4.5 52 1 18 PF2D540-19 Internal Circuits and Wiring Examples 78 86 186 -1/2 Analog voltage output Analog current output 56 15 Sensor Monitor PF2D3 Black Output for PF2D3 4 8 Switch output Main circuit Main circuit Main circuit Main circuit 3 7 U DC
SET Proceed to the auto shift mode. 16-3-15 15 Series PSE530/200 Operation 3: Special Setting 3 Auto shift Refer to C Auto shift function on page 16-3-17 for details.
NCA1-AC325 NCA1-AC800 NCA1-AC1000 A 3/4-16 1-14 1 1/4-12 B 1 3/4 2 1/2 2 1/2 C 2 5/16 2 15/16 2 15/16 D 5/16 1/2 1/2 E 1 1/8 1 5/8 1 5/8 F 31/32 1 3/8 1 3/8 G 7/8 1 1/4 1 1/4 Pivot Pins CP DD CL CD CL CD Dimensions Dimensions CL 2 5/8 3 1/8 4 1/8 CP 2.72 3.22 4.25 Part No. NCA1-325 NCA1-800 NCA1-1000 CD 3/4 1 1 3/8 Part No.
2 28 DIN connector 233 Series VCH400 Dimensions VCH410 G1/4 x 7 Pilot EXH G1/2, 3/4:97 G1:102 41 17.5 62 50.5 17 16 (6) 106 (76) 42.5 51.5 G1/2 Applicable cable O.D. 6 to 12 3(EXH) 188 3 3 2(OUT) 2 2 75 15 1 1 66 47 28 50 2 x 8.5 Mounting hole 3 x G1/2 x 15 G1/2, 3/4: 70 G1: 80 3 x G3/4 x 16.3 3 x G1 x 19.1 1(IN) 234 Made to Order Made to Order Specifications: Please consult with SMC for
Compact size (Width: 15 mm) Low power consumption: 1.8 W DC Valve configuration Pilot type 4 port solenoid valve Air 0.15 to 0.7 10 to 50 (No freezing. Refer to page 3-13-4.) 15 or less 15 Refer to the table below.
0.5 MPa Flow rate (l/min (ANR)) Effective area (mm2) Effective area (mm2) 300 06 07,08,09 2 4 200 100 1 2 100 0 0 0 5 10 0 5 10 Number of needle rotations Number of needle rotations ASP530F ASP630F 1500 1000 14 Flow rate (l/min (ANR)) Inlet pressure : 0.5 MPa Inlet pressure : 0.5 MPa Flow rate (l/min (ANR)) Effective area (mm2) Effective area (mm2) 20 10 11,12,13 12 10,11 08,09 1000 10 15
The installation torque is 0.3 to 0.5 Nm. 14-11-15
Option Blank plate AXT512-9A Model Effective area (WitH sub-plate) (mm 2) (Nl/min) Response time (2) (sec) Weight (3) (kg) 0.040 or less 0.020 or less 0.05 or less 0.05 or less 0.06 or less Max. operating rate (1) No. of positions Model 3 8 (cycle/sec) 15 15 10 10 8 VS7-8-FG-S--Q VS7-8-FG-D--Q VS7-8-FHG-D--Q VS7-8-FJG-D--Q VS7-8-FPG-D--Q 58 (3140.80) 58 (3140.80) 58 (3140.80) 58 (3140.80)
VS3135 XT019-6 XT013-13-2 XT010-15 Description VS3145 No. Cap AXT103-4 XT021-12 XT103-5 XT010-20 XT010-21 XT041-1 Resin Resin Bushing Spring Rubber plug for wire Round head combination screw Plug for cover r t y u i o Gasket XT013-31-2 NBR NXT030-8 !
Applicable Auto Switch/Refer to page 9-15-1 for further information on auto switches.
RZQ Lever type (3) Energy absorbing Adjustable deformation MI W S Cylinder stroke (mm) 12 16 20 32 40, 50 10 10, 15 10, 15, 20 10, 15, 20 20, 25, 30 Double acting Double acting with spring loaded Single acting (Spring extend) Note 3) The lever types are applicable only to bore sizes 32, 40 and 50.