The VX3000 series is a direct operated, 3 port solenoid valve, for use with a wide variety of fluids. When used in combination with the manifold, configuration can be changed from N.C. to N.O. and from N.O. to N.C. by simply changing a gasket. Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure
The VX3000 series is a direct operated, 3 port solenoid valve, for use with a wide variety of fluids. When used in combination with the manifold, configuration can be changed from N.C. to N.O. and from N.O. to N.C. by simply changing a gasket. Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure
Valves for both are easily replaced without changing existing piping.Direct air operated, 2 port valve for manifold, N.C. or N.O. style, Compatible with a wide variety of fluids, Effective area mm2 (Cv): 6~19 (0.33~1.05), Max. system pressure (MPa): 1.0, "VALVE, VXA, 2 PORT VALVE
Valves for both are easily replaced without changing existing piping.Direct air operated, 2 port valve for manifold, N.C. or N.O. style, Compatible with a wide variety of fluids, Effective area mm2 (Cv): 6~19 (0.33~1.05), Max. system pressure (MPa): 1.0, "VALVE, VXA, 2 PORT VALVE
Valves for both are easily replaced without changing existing piping.Compatible with a wide variety of fluids, Maximum operating pressure (MPa): 0.3~1.0, Effective area mm 2 (Cv): 1.4~9 (0.08~0.5), Orifice size (mm): 1.5, 2.2, 3, 4, Maximum system pressure: 1.0, "VALVE, VXA, 2 PORT VALVE, N lb
The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110
The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110
The SYJ Valve is an innovative combination of space efficiency and performance superiority which provides real value to the design solution. Whether designed in a manifold or used as a single valve, this small profile increases design flexibility and minimizes space requirements. The SYJ valve utilizes a low power (0.5 watts standard) pilot solenoid design, which dramatically reduces thermal
The SYJ Valve is an innovative combination of space efficiency and performance superiority which provides real value to the design solution. Whether designed in a manifold or used as a single valve, this small profile increases design flexibility and minimizes space requirements. The SYJ valve utilizes a low power (0.5 watts standard) pilot solenoid design, which dramatically reduces thermal
The SYJ Valve is an innovative combination of space efficiency and performance superiority which provides real value to the design solution. Whether designed in a manifold or used as a single valve, this small profile increases design flexibility and minimizes space requirements. The SYJ valve utilizes a low power (0.5 watts standard) pilot solenoid design, which dramatically reduces thermal
The SYJ Valve is an innovative combination of space efficiency and performance superiority which provides real value to the design solution. Whether designed in a manifold or used as a single valve, this small profile increases design flexibility and minimizes space requirements. The SYJ valve utilizes a low power (0.5 watts standard) pilot solenoid design, which dramatically reduces thermal
The SYJ Valve is an innovative combination of space efficiency and performance superiority which provides real value to the design solution. Whether designed in a manifold or used as a single valve, this small profile increases design flexibility and minimizes space requirements. The SYJ valve utilizes a low power (0.5 watts standard) pilot solenoid design, which dramatically reduces thermal
The SYJ Valve is an innovative combination of space efficiency and performance superiority which provides real value to the design solution. Whether designed in a manifold or used as a single valve, this small profile increases design flexibility and minimizes space requirements. The SYJ valve utilizes a low power (0.5 watts standard) pilot solenoid design, which dramatically reduces thermal
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, "POWER VALVE, VEX, PROPORTIONAL VALVE, N lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com