Series CXS is available in six bore sizes and stroke lengths up to 100mm. This series is very compact and has a very accurate non-rotating specification. It is suited for accurate pick-and-place applications or light duty material handling. The CXS can be used with either reed or solid state switches. Available in clean room versions. Dual rod cylinder with slide bearing, Bore sizes: 6, 10
Dual rod cylinder with air cushion, Slide bearing or ball bushing bearing, Bore sizes: 20mm, 25mm, 32mm, Standard strokes: 20-100mm, Thread types: M, Rc, NPT, G, Auto switches available "Cylinder. GUIDED CYLINDER. N lb. CXS.
Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side, Temperature: 5 to 60°C, Version: 2 (Refresh), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: B (1pc, Valve Open)
Flange Size: 40, Flange Type: KF(NW), Port Direction: Flange Side, Temperature: 5 to 60°C, Version: 2 (Refresh), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: L (3m), Number: A (2pcs, Valve Open/Closed)
The 100mm slide bushing model can stop a load of 3,000 lbs. traveling at 55ft/min, or smoothly lift a centered load of 1,000 lbs. with a 40% safety factor. The overall package is very compact, and pre-tapped mounting holes ensure easy attachment of fixtures. Mounts on side or bottom.
Applications that call for precise movement ranging from 10-150mm * typically require a cylinder and a precision guide. The MXS accomplishes this by integrating a cross roller bearing with a guide and two small air cylinders for compact force generation. The MXS is available in six sizes each with set stroke lengths and is standard with auto switch capability. Stroke adjustments are available
Body Size: 40, Back Flow: w/o Backflow, Thread: Rc, Port Size: 04 (1/2), Options: M (Round Type Pressure Gauge, w/Color Zone), Set Pressure: 0.05 to 0.85 MPa Setting, Bowl: 6 (Nylon Bowl), Bowl Guard: None, Drain Port: w/Drain Cock, Exhaust Mechanism: Relieving Type, Flow Direction: Flow Direction: Left to Right, Drain Cock w/Barb Fitting: W (Drain Cock w/Barb Fitting), Pressure Units: Product
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 3/4, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: Yes, Lead Wire: w/M12 -M8 Conversion Lead Wire, 0.1 m, Unit Specification: Instantaneous Flow: gal/min; Accumulated Flow: gal; Temperature: °C, Bracket: None, Calibration
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 3/4, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None, Calibration Certificate
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 1/2, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: gal/min; Accumulated Flow: gal; Temperature: °C, Bracket: None, Calibration Certificate
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 3/4, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None, Calibration Certificate
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 1/2, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None, Lead Wire: w/M12 -M8 Conversion Lead Wire, 0.1 m, Unit Specification: Instantaneous Flow: gal/min; Accumulated Flow: gal; Temperature: °C, Bracket: None, Calibration
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 1/2, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None, Lead Wire: w/M12 -M8 Conversion Lead Wire, 0.1 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None, Calibration Certificate
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 3/4, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None, Lead Wire: w/M12 -M8 Conversion Lead Wire, 0.1 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None, Calibration Certificate
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 3/4, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: Yes, Lead Wire: w/M12 -M8 Conversion Lead Wire, 0.1 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None, Calibration Certificate
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 1/2, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None, Calibration Certificate
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: G, Port Size: 1/2, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None, Calibration Certificate
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 10 (1), Output Specification/Temperature Sensor: L2 (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: None), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 10 (1), Output Specification/Temperature Sensor: L2T (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 10 (1), Output Specification/Temperature Sensor: LT (Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket