Please note that the graph should only be used as a guide as there is a tolerance of about 10% in the clamp cylinder body. D) In the state of C), adjust shim so that the arm side block contacts the workpiece.
AC 110 12 2 12 3 q e w e t y 220 10 1 10 1.5 440 6 1 3 1 550 5 0.8 2 0.5 r b contact w a contact r q DC 24 3 2.5 3 2.5 C C 48 1.5 1.2 1.5 1.25 When rising pressure q w = ON e r = OFF When rising pressure q e r y = ON q w r t = OFF 110 0.5 0.25 0.5 0.2 220 0.25 0.1 0.25 0.1 Insulation resistance: 100 M or more at 500 VDC by megameter Voltage resistance: 2000 VAC/1 min. 16-9-5 2 Series
L O L G H F K J E D I A B C 2-4.5 A B C D E F G H I J K L Model 4 ZFC100-04 6 ZFC100-06 53.2 9.1 30 14.1 10 18 11.6 19.5 23 20 29 5/32" ZFC101-03 1/4" ZFC101-07 6 ZFC200-06 8 ZFC200-08 67 15.5 34 17.5 14 22 15.6 23.1 27 24 35 1/4" ZFC201-07 5/16" ZFC201-09 Element Replacement Element replacement procedure 1) Stop operation and reduce the filter's internal pressure to atmosphere. 2) Turn cover
C 10 to 30 Cooling capacity Note 3), 11) (50/60 Hz) W 1000/1200 For option -T: 900/1100 1400/1600 For option -T: 1300/1500 Temperature stability Note 4) C 2 Circulating uid system Pump capacity (50/60 Hz) Note 5) MPa 0.08 (at 7 L/min)/0.11 (at 7 L/min) For option -T: 0.13 (at 7 L/min)/0.18 (at 7 L/min) Rated ow (50/60 Hz) Note 6) L/min 7/7 Tank capacity L Approx. 5 Port size Rc1/2 Fluid
A5 A5 A6 A6 A7 A7 Internal Internal A8 A8 resistance resistance 10[k ] 10[k ] 24 VDC 24 VDC A9 A9 Main circuit Main circuit power supply power supply for the input for the input A10 A10 signals signals B1 B1 B2 B2 B3 B3 B4 B4 B5 B5 Maximum output Maximum output B6 B6 current: 10 mA current: 10 mA B7 B7 Pulse input internal circuit Note2) B8 Pulse input internal circuit Note2) B8 Pulse input
equipment +10% 15% +10% 15% Single phase 200 to 230VAC (50/60Hz) For 100V Single phase 100 to 115VAC (50/60Hz) R T 1MCCB Noise filter External noise is prevented by the noise filter Servo malfunction indicator PL For power supply switching Power supply 5Ry ON 1MC A surge voltage suppressor should be attached to the electromagnetic contactor and relay.
(Including O-ring for element) 5 m 10 m 20 m Model FH150-02 FH150-03 FH150-04 Element size EP910-005N EP910-010N EP910-020N 55 x 90 Note 1) The symbol at the end of the element part no. indicates the hydraulic fluid type. N: Petroleum, V: Phosphoric ester, W: Water-glycol, Emulsion (10 m only) Note 2) Refer to page 528 for micromesh elements.
C, prevent water droplets from entering the inlet port. (No freezing of the fluid) * Note 2. ANR indicates the flow rate converted to the value at 20 deg. C, under the atmospheric pressure and the state of relative humidity 65%. * Note 3.
Applicable cable Cable O.D. : 4.5 to 7 (Reference ) 0.5 mm2 to 1.5mm2, 2-core or 3-core, equivalent to JIS C 3306 Applicable crimped terminal O terminal : Equivalent to R1.25-3 that is specified in JIS C 2805 Y terminal : Equivalent to 1.25-3, which is released by JST Mfg.Co.,Ltd Use O terminal when a ground terminal is used. 10 No.VF1000-OMN0002-A VF1000/3000/5000 Series Specific Product
Recommended Sonic Conductance and Solenoid Valves (Reference) C [dm3/(sbar)] ZH10--X185 1.48 or more ZH20--X185 3.12 or more ZH30--X185 5.92 or more ZH40--X185 11.08 or more Model VQZ200 VP300 VP500 VP700 Solenoid valve (Reference) Sonic conductance C [dm3/(sbar)]: 1.7 Sonic conductance C [dm3/(sbar)]: 4.2 Sonic conductance C [dm3/(sbar)]: 8.9 Sonic conductance C [dm3/(sbar)]: 15.3 791 C
Applicable cable Cable O.D.: 4.5 to 7 (Reference) 0.5 mm2 to 1.5mm2, 2-core or 3-core, equivalent to JIS C 3306 Applicable crimped terminal O terminal: Equivalent to R1.25-3 that is specified in JIS C 2805 Y terminal: Equivalent to 1.25-3, which is released by JST Mfg.Co.,Ltd Use O terminal when a ground terminal is used. 10 No.VP300-OMM0002-A VP Series Specific Product Precautions 4 Be
C A , C D A F A 2 C A , C D A F A 2 C A , C D A F A 2 C A , C D A F A 2 C A F A 2 C A F A 2 C A F A 2 C A t e n n o B C D A r e b m a h C F A 2 C A , C D A F A 2 C A , C D A F A 2 C A , C D A F A 2 C A , C D A F A 2 C A F A 2 C A F A 2 C A F A 2 C A e d i u g e v l a V F A 2 C A , C D Z F A 2 C A , C D Z F A 2 C A , C D Z F A 2 C A , C D Z F A 2 C A F A 2 C A F A 2 C A F A 2 C A ) f g k (
Fluid Vacuum of inert gas Ambient temperature: 20 oC 5 to 60 (5 to 150 for high temperature type) Operating pressure Pa Atmospheric pressure to 1 x 10-5 Main exhaust valve 200 300 800 Conductance l/s Note 1 Bypass valve MAX31.5Viscosity / Theoretical value Internal 1.3 x 10-9 for the standard material (FKM) at ambient temperature, excluding gas permeation Leakage Pam3/s External 1.3 x 10-
SUS304> 5 (SUS304) () 2 4 (A6063) < A6063> C D E E F C H B G A A mm A B C D E F G H XLH-16 40 100.5 38 1 30 17 35 XLH-25 50 114 48 1 12 40 26 41 XLH-40 65 162.5 66 2 11 55 41 57 XLH-50 70 179.5 79 2 11 75 52 70 8 XL-OMY0003
5 10 []18 12 O 1) FKM M 10 FKM : 110 Pa <> 9 XL-OMY0003
6 6-1. 1 1P4P5 10 XL-OMY0003
6-2 1 2 b 3 1 2 O 4 a aa b O O
Take note that the leakage voltage will increase when a resistor is used in parallel with a switching element or when a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the leakage voltage passing through the C-R circuit. The suppressor residual leakage voltage should be as follows. 8.
Release of residual pressure resistor is used in parallel with switching element or a C-R circuit (surge voltage suppressor) is used for protecting a For maintenance purposes install a system for releasing switching device because of the passing leakage voltage residual pressure. 6. Operation in a vacuum condition through the C-R circuit.
Table 1: Stroke adjustment range (Without spacer, with short spacer, with long spacer) -10 -20 -30 -40 -50 0 0 to 10 10 to 20 20 to 30 L unit MY2*16 Without spacer Short spacer Long spacer H unit 0 to 12 12 to 24 24 to 36 L unit MY2*25 Without spacer Short spacer Long spacer H unit 0 to 16 16 to 32 32 to 48 L unit H unit Without spacer MY2*40 Short spacer Long spacer -9- Warning 1.
DRail mounting Direct mounting 20D-A7H/A80H D-A73C/A80C D-F7BAL/F7BAVL D-F7/J79 D-F7V/J79C D-F7W/F79F D-F7WV D-J79W D-M9 D-M9V D-F9W D-F9WV D-F9BA D-A7/A80 D-A79W D-A9 D-A9V Bore size (mm) A 9 13 11 13.5 B 6 8.5 11.5 14.5 A 9.5 13.5 11.5 14 B 6.5 9 12 15 A 6.5 10.5 8.5 11 B 3.5 6 9 12 C 8 12 10 12.5 D 5 7.5 10.5 13.5 C 12 16 14 16.5 D 9 11.5 14.5 17.5 C 11 15 13 15.5 D 8 10.5 13.5 16.5 32
DRail mounting Direct mounting 20D-A7H/A80H D-A73C/A80C D-F7BAL/F7BAVL D-F7/J79 D-F7V/J79C D-F7W/F79F D-F7WV D-J79W D-M9 D-M9V D-F9W D-F9WV D-F9BA D-A7/A80 D-A79W D-A9 D-A9V Bore size (mm) D 8 10.5 13.5 16.5 C 11 15 13 15.5 D 9 11.5 14.5 17.5 C 12 16 14 16.5 D 5 7.5 10.5 13.5 C 8 12 10 12.5 B 3.5 6 9 12 A 6.5 10.5 8.5 11 B 6.5 9 12 15 A 9.5 13.5 11.5 14 B 6 8.5 11.5 14.5 A 9 13 11 13.5 32
D E F G H J Model 1 8 1 4 1 4 VND50D-32A VND60D-40A VND70D-50A 1 4 1 2 1 1 2 105 120 140 77 96 113 53 60 74 26.5 30 37 121.5 138 161 20 24 24 130.5 148 171 8 10 12 55 63 74 LVA LVH LVD Port size Flange: 32F, 40F, 50F LVQ J (Valve open) LQ Indicator (Option) LVN Pilot port TI/ TIL PA PAX PB 4 x 2-18 mounting hole Applicable flange Pilot port Rc A B C D E F G H J Model 8 10 12 50 40 32 1 8