Applicable model 02 03 04 06 10 1/4 3/8 1/2 3/4 1 8 3 Pressure gauge 3 4 5 6 1 AMR300-02/03 AMR400-02 to 04 AMR500-04 to 06 AMR600-10 3 4 5 6 1 2 Nil E2 E3 E4 E6 E10 None None With pressure switch S Nil 4 3 1/4 3/8 1/2 3/4 1 Port size Adapter assembly Thread type Symbol Port size Nil N F Rc NPT G Thread type 02 03 04 06 10 1/4 3/8 1/2 3/4 1 The port size of adapter assembly is same as the
E 3 Auto drain Additional symbol Port size 1 None With auto drain 0 Flow direction: left to right MR unit Flow direction: right to left 02 03 04 06 10 1/4 3/8 1/2 3/4 1 Applicable model AMR300-02 to 03 AMR400-02 to 04 AMR500-04 to 06 AMR600-10 R 3 4 5 6 Body size 3 4 5 6 Adapter ass'y port size (2 pcs.) 8 3 standard standard standard Pressure switch 1 2 E2 E3 E4 E6 E10 None With pressure
Electrical entry SC (T only) Type SU Type SC Type SC Type SU Type SC Type SU AXT622-5A AXT336-4AStations AXT336-5Stations Description AXT336-1A-1 01 02 01 02 01 02 02 03 02 03 02 03 02 03 Manifold block assembly AXT336-1A-2 AXT336-1A-3 AXT336-2A-1AXT336-2A-2AXT336-3A-1AXT336-3A-2q End plate (U side) assembly w End plate (D side) assembly e Terminal assembly Junction cover assembly Tie-rod
For the IR400-02/03/04□□: IR3000-02/03/04□□-A
For the IR401-02/03/04□□: IR3010-02/03/04□□-A
For the IR402-02/03/04□□: IR3020-02/03/04□□-A
For the IR412-02/03/04□□: IR3120-02/03/04□□ (IR-A series air operated regulators will be available at a later date.)
Note) Select option “H” when panel mounting the product.
Tap water : Standard of The Japan Refrigeration and Air Conditioning Industry Association(JRA GL-02-1994) Deionized water : Electric conductance 0.4 S/cm or higher (Electrical resistivity 2.5Mcm or lower) (Note2) (1)Facility water temp. : 32, (2)Circulating fluidTap water, (3)Circulating fluid temp. : CH1:20/CH2:25, (4)Circulating fluid rated flow:Rated flow, (5)Power supply200 VAC.
Helium leak volume 4.0 x 10-9 Pam3/sec or less Case/Cover Stainless steel 316 (Interior/Exterior: Electrolytic polishing) Main material Filter medium PTFE membrane Seal Fluororubber (FKM) -8- 2-3 Dimensions 1) SFC100-02, SFC100-03 Model A SFC100-02 Rc1/4 SFC100-03 Rc3/8 2) SFC102-02, SFC102-03 Model A SFC102-02 TSJ1/4 SFC102-03 TSJ3/8 3) SFC105-02, SFC105-03 Model A B C SFC105-02 URJ1/4 22
L1 L2 L3 L4 L5 L6 L7 L8 D Model Bore size ASS AS2000-01 AS2000-02 AS3000-02, 03 1 8 Rc Rc Rc , 40 40 56 30 30 45.5 5 5 5.25 17 23 25 10 11.5 13.2 15.5 17 20.6 54.5 56 68 50 51.5 61 16 20 26 4.5 4.5 5.5 1 4 1 4 ASR Effective thread depth 6 8 3 Dimensions: AS5000 ASF 2-1/4 to 1/2 2-M4 x 0.7 Effective thread depth 7 15-9-31
Load factor: ((Load weight x 9.8)/Theoretical force) x 100% VS4 VQ7 EVS Conditions VFN Base mounted Series MB Series CS1 6A x 1 m AS4000-02 AN200-02 10A x 1 m AS420-03 AN300-03 6A x 1 m AS4000-02 AN200-02 10A x 1 m AS420-03 AN300-03 Base mounted Series MB Series CS1 10A x 1 m AS4000-03 AN300-03 15A x 1 m AS420-04 AN400-04 10A x 1 m AS4000-03 AN300-03 15A x 1 m AS420-04 AN400-04 SGP (Steel
Note 3) Polyurethane is only applicable for the ZFC050-02. SP ZCUK Made to Order (Refer to page 1115 for details.)
VY1 How to Order G PPA Internal pilot operated relieving type regulator AR 25 4 BG R 02 Option Nil Flow direction: Right Left AL None Regulator R Body size Accessory 4 6 8 9 1 2 1 Symbol Description Applicable model Port size 1 Nil 1 4 02 03 04 06 10 12 14 20 2 1 With bracket AR45 to 65 AR25 AR35 B 8 3 2 G46-10-02 G46-2-02 Gauge 1 2 3 4 G Regulating pressure range Pressure gauges are shipped
IITV20 02 5 Example AV Valve stations Electro-pneumatic regulator Blanking plate assembly ITV1030-311S-X26 2 2 stations P398020-13 AU 8 8 stations Electro-pneumatic regulator LOCK UNLOCK RESET SET AF ITV2050-212S-X26 E SMC REGULATOR OUT port size ITV1000/2000 P 02 03 1/4 3/8 LOCK UNLOCK RESET SET MPa AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-
Option Body material Nil N Body only With silencer 1 2 ADC12 (Aluminum) SCS14 (Stainless steel) For AIR EXH: AN200-02 Port size Diaphragm material 02 03 1/4 (8A) 3/8 (10A) 1 PTFE (Fluoro resin) JIS Symbol Type Thread type Nil T Automatically operated type built-in pulsation attenuator Rc NPTF G NPT FLUID OUT AIR SUP 2 F N AIR EXH FLUID IN T, F, N are options.
Model Pressure range *1 Indication unit Connection thread Note MPa Port size 01 Rc1/8 02 Rc1/4 R1/8 R1/4 G46-7-02-SRB 0 to 0.7 R1/4 G46-10-02-SRB 0 to 1.0 G46-4-01 to 02-SRB 0 to 0.4 MPa Set pressure range: 0.05 to 0.69 MPa 02 WR110 X215 *1: Do not apply more pressure than the max. pressure displayed. It may cause a malfunction.
Load factor: ((Load weight x 9.8)/Theoretical force) x 100% VS4 VQ7 EVS Conditions VFN Base mounted Series MB Series CS1 6A x 1 m AS4000-02 AN200-02 10A x 1 m AS420-03 AN300-03 6A x 1 m AS4000-02 AN200-02 10A x 1 m AS420-03 AN300-03 Base mounted Series MB Series CS1 10A x 1 m AS4000-03 AN300-03 15A x 1 m AS420-04 AN400-04 10A x 1 m AS4000-03 AN300-03 15A x 1 m AS420-04 AN400-04 SGP (Steel
E 3 Auto-drain Pressure gauge mounting Port size 02 03 04 06 10 ARJ MR unit 1 None With auto drain 0 Flow direction: Right to left Nil Flow direction: Left to right Applicable model 1/4 3/8 1/2 3/4 1 Nil E2 E3 E4 E6 E10 R 3 4 5 6 AMR3 00-02 to 03 AMR4 00-02 to 04 AMR5 00-04 to 06 AMR6 00-10 AR425 to 935 Adapter assembly port size (2 pcs.)
Request message to read (from master) 02 30 31 52 50 56 31 03 65 Request to read Address BCC data End code Identification code Start code Response message from the product 02 30 31 06 50 56 31 30 30 32 35 30 03 06 Address Start code BCC data Affirmation code End code Numerical data Identification code Code Symbol/Data ASCII code Start code STX 02H Address 01 30H 31H Required content R
Request message to read (from master) 02 30 31 52 50 56 31 03 65 Address BCC data End code Request to read Start code Identification code Response message from the product 02 30 31 06 50 56 31 30 30 32 35 30 03 06 Address BCC data End code Start code Numerical data Affirmation code Identification code Code Symbol/Data ASCII code Start code STX 02H Address 01 30H 31H Required content R
Screw tightening torque VO307K: 1.35 to 1.45 Nm V11 : 0.14 to 0.17 Nm Parts for manifold 02 03 04 02 03 04 04 06 10 01 02 10 12 01 02 14 20 Description VEX312VEX322VEX332VEX342VEX350VEX370VEX390Bracket (with bolt and washer) VEX1-18-1A VEX5-32A VEX7-32A VEX9-32A Foot bracket (with bolt and washer) VEX1-18-2A VEX3-32-2A Silencer for pilot exhaust port (PE) AN120-M5 AN103-01 AN210-02 Note 1
Type Type Elbow type straight type In-line type REA25 AS2201F-01-06-X214 AS2301F-01-06-X214 AS2001F-06-X214 REA32 AS2201F-01-06-X214 AS2301F-01-06-X214 AS2001F-06-X214 REA40 AS2201F-02-06-X214 AS2301F-02-06-X214 AS2001F-06-X214 REA50 AS3201F-02-08-X214 AS3301F-02-08-X214 AS3001F-08-X214 REA63 AS3201F-02-08-X214 AS3301F-02-08-X214 AS3001F-08-X214 Table.
1 Thread size M5 01 02 03 04 M5 x 0.8 R R R R 1 8 1 4 3 8 1 2 M5 port only Note 1) AS221: Electroless nickel plated Note 2) AS221: Steel Note 3) Meter-in type: Black zinc chromated 15-9-8 2 Speed Controller with One-touch Fitting Elbow Type (Metal Body) Series AS Flow Rate and Effective Area AS321-03 AS421-04 AS221-01 AS221-02 AS121-M5 Model Tubing O.D. 12 10 10 8 6 8 4, 6 6, 8 Controlled