Ensure input branch current does not exceed the specification range. 3 Mode No.4 Number of branch Valid port A OFF 16 points per port COM A and B B ON 8 points per port COM A to D Check the connection of UNLIT COM port branch to input unit. 4 COM A-D is not LIT 23 22
Add to Cart SMC AXT100-DR-22 din rail, VV5Q* MANIFOLD VQ 4/5 PORT*** $8.60 + Add to Quote Add To Cart Add to Cart SMC AXT100-DR-23
Add to Cart SMC AXT100-DR-22 din rail, VV5Q* MANIFOLD VQ 4/5 PORT*** $8.60 + Add to Quote Add To Cart Add to Cart SMC AXT100-DR-23
Actuation: 3 (3 Postion Closed Center), Piping/EXH: 23 (Body Ported), Coil Specification: Standard, Voltage: 5 (24 VDC), Electrical Entry: D (DIN Terminal, w/Connector), Light/Surge Voltage Suppressor: Z (w/ Light/Surge Voltage Suppressor), Manual Override: D (Push-turn Locking Slotted Type), Port Size: 01 (1/8 w/Sub-plate, Piping 23 w/o Sub-plate), Thread: T (NPTF)
Actuation: 3 (3 Postion Closed Center), Piping/EXH: 23 (Body Ported), Coil Specification: Standard, Voltage: 5 (24 VDC), Electrical Entry: DO (DIN Terminal, w/o Connector), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: D (Push-turn Locking Slotted Type), Port Size: 01 (1/8 w/Sub-plate, Piping 23 w/o Sub-plate), Thread: T (NPTF)
Actuation: 3 (3 Postion Closed Center), Piping/EXH: 23 (Body Ported), Coil Specification: Standard, Voltage: 5 (24 VDC), Electrical Entry: DO (DIN Terminal, w/o Connector), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: E (Push-turn Locking Lever Type), Port Size: 01 (1/8 w/Sub-plate, Piping 23 w/o Sub-plate)
Actuation: 1 (2 Position Single), Piping/EXH: 23 (Body Ported), Coil Specification: Standard, Voltage: 5 (24 VDC), Electrical Entry: D (DIN Terminal, w/Connector), Light/Surge Voltage Suppressor: Z (w/ Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size: 01 (1/8 w/Sub-plate, Piping 23 w/o Sub-plate), Thread: T (NPTF)
Actuation: 1 (2 Position Single), Piping/EXH: 23 (Body Ported), Coil Specification: Standard, Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Connector, w/o Connector), Light/Surge Voltage Suppressor: Z (w/ Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size: 01 (1/8 w/Sub-plate, Piping 23 w/o Sub-plate), Thread: T (NPTF)
Actuation: 1 (2 Position Single), Piping/EXH: 23 (Body Ported), Coil Specification: Standard, Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: D (DIN Terminal, w/Connector), Light/Surge Voltage Suppressor: Z (w/ Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size: 01 (1/8 w/Sub-plate, Piping 23 w/o Sub-plate), Thread: N (NPT)
Actuation: 1 (2 Position Single), Piping/EXH: 23 (Body Ported), Coil Specification: Standard, Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: D (DIN Terminal, w/Connector), Light/Surge Voltage Suppressor: Z (w/ Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size: 01 (1/8 w/Sub-plate, Piping 23 w/o Sub-plate), Thread: T (NPTF)
Actuation: 1 (2 Position Single), Piping/EXH: 23 (Body Ported), Coil Specification: Standard, Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: G (Grommet, Lead Wire 300mm), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Port Size: 01 (1/8 w/Sub-plate, Piping 23 w/o Sub-plate), Thread: N (NPT)
Actuation: 3 (3 Postion Closed Center), Piping/EXH: 23 (Body Ported), Coil Specification: Standard, Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Connector, w/Lead Wire 300mm), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: E (Push-turn Locking Lever Type), Port Size: 01 (1/8 w/Sub-plate, Piping 23 w/o Sub-plate)
Actuation: 3 (3 Postion Closed Center), Piping/EXH: 23 (Body Ported), Coil Specification: Standard, Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Connector, w/Lead Wire 300mm), Light/Surge Voltage Suppressor: Z (w/ Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size: 01 (1/8 w/Sub-plate, Piping 23 w/o Sub-plate), Thread: T (NPTF)
treatment Diaphragm shell holder Seal 1 1 Stem O-ring 1 1 JIS B2401 P7 Valve O-ring 1 1 Rubber lining material: HNBR JIS B2401 P10 Valve guide O-ring 1 1 Chromate treatment Industrial Filters Static pressure tube O-ring 1 1 JIS B2401 P20 Set nut O-ring 1 1 JIS B2401 P42 Bonnet O-ring 1 1 Chromate treatment JIS B2401 G70 Valve seat Steel ball 1 1 5 Diaphragm holder Retaining ring 1 1 TE-23
Note 2) Applicable fittings Note 2) 3) One-touch fittings, Insert fittings, Self-align fittings, Miniature fittings Caution Min. bending radius Min. bending 15 12 23 17 45 34 55 42 65 50 90 70 18 12 27 15 30 23 55 42 65 50 radius mm Note 4) Bending value (Reference) 1. Compatible with water due to a change in materials.
Bodysize Metricsize Inchsize 100 200 205 300 400 M3,M5standard 1/8standard 1/4standard 3/8standard 1/2standard Grease-free(Sealant:Fluorocoated)+ Restrictor(WithoutCheckValve) -X21 02 23 04 06 08 10 12 01 03 07 09 11 13 1/8" 5/32" 1/4" 5/16" 3/8" 1/2" 2 3.2 Ex.)AS2002F-04-X21 Note)Notparticle-free 4 6 8 10 12 Withone-touchfittings Restrictor(WithoutCheckValve) -X214 Use1/8"tube.
Port size ASV Model M3 x 0.5 ASV120F-M3 0.3 0.3 AK M5 x 0.8 ASV220F-M5 1.3 1.3 R 1/8 ASV310F-01 8 7 ASS R 1/4 ASV310F-02 8 7 R 1/8 ASV410F-01 14 13.5 ASR R 1/4 ASV410F-02 14 13.5 R 3/8 ASV410F-03 14 13.5 ASF R 1/4 ASV510F-02 27 23 R 3/8 ASV510F-03 29 27 R 1/2 ASV510F-04 29 27 10-32 UNF 1.3 1.3 ASV220F-U10/32 NPT 1/8 ASV310F-N01 8 7 NPT 1/4 ASV310F-N02 8 7 NPT 1/8 ASV410F-N01 14 13.5 NPT 1
Add to Cart SMC AXT100-DR-22 din rail, VV5Q* MANIFOLD VQ 4/5 PORT*** $8.60 + Add to Quote Add To Cart Add to Cart SMC AXT100-DR-23
Add to Cart SMC AXT100-DR-22 din rail, VV5Q* MANIFOLD VQ 4/5 PORT*** $8.60 + Add to Quote Add To Cart Add to Cart SMC AXT100-DR-23
An application which has the possibility of having negative effects on people, property, or animals, requiring special safety analysis. 23 Process Pump Common Precautions 1 Be sure to read before handling. Refer to the main catalog sections for detailed precautions on each series. Precautions on Design Warning Warning 1. Confirm the fluid to be used.