SMC Corporation of America
Elite Part Number Search
Search Results "PVQ13-5LO-08-M5-A"

, 40, 50, 75, 100, 125, 150, 175, 200 20, 30, 40, 50, 75, 100, 125, 150, 175, 200 26 64 17 10 19 52 74 2 8.5 4 46 36 72 8 30 10 60 37 13 18 47 8 M5 x 0.8 13 M5 x 0.8 7 M5 x 0.8 Rc 1/8 10.5 32 76 21 10 21 62 88 2 9 2 56 42 86 8 38 12 70 37.5 14 26 47.5 9 M6 x 1.0 15 M6 x 1.0 8 M6 x 1.0 Rc 1/8 11.5 MGQM (Slide bearing) A, DB, E Dimensions MGQL (Ball bushing bearing) A, DB, E Dimensions E E

Use this as a standard when mounting, etc. Misc.

Use this as a standard when mounting, etc. Misc.

A MPa ON kPa OUT1 OFF OUT2 CH 1 2 3 4 PRESSURE Min. B Released SET Work 1 Work 2 Work n Atmosphere Max. A: Maximum pressure value when work piece is adsorbed. A B 4 ON = A A B 4 SET OFF = B + Min. B: Minimum pressure value when work piece is not adsorbed. OUT1 auto preset For adsorption verification: In this mode, repeat the adsorption and release of the work piece for a few times.

In actual application, only one color is displayed at a time. Abnormal conditions can be detected at a glance!

6 15 8 0 -0.3 18.3 9.5 21 28 55.5 + Stroke 83.5 + Stroke With rear end lock / CBJ2B16-HN 0 h8-0.022 10 6 2-M10 x 1 Piping port 2-M5 x 0.8 8 M5 x 0.8 20 19.8 5 0 -0.3 18.3 12.5 15 8 12.5 50 + Stroke 8 28 86 + Stroke 3 Series CBJ2 Dimensions Flange With front end lock / CBJ2F16-RN 14.5 M10 x 1 Cover side (rear side) Piping port 2-M5 x 0.8 5 6 20 M5 x 0.8 20.3 19 20 2-5.5 Mounting hole 2.3

Proper auto switch mounting positions (Series CE1) (mm) Bore size (mm) Auto switch model Symbol 20 32 40 50 63 12 A B A B A B A B A B A B A B A B A B 40.5 47 55 79 82 85.5 D-A7, A8 4 13 17 39 44 41.5 Contact protection box internal circuits 41 47.5 55.5 79.5 82.5 86 D-A7H, A80H, A73C, A80C, D-F7, J79, F7V, J79C 4.5 13.5 17.5 39.5 44.5 42 Choke coil OUT Brown [Red] CD-P11 38 44.5 52.5 76.5

C 0.2 B 0.2 A 0.2 Hexagon socket head mounting screws D Bore size (mm) A (mm) B (mm) C (mm) MGPM MGPL W 20 12 54 14 M5 x 0.8 24 72 25 18 15 M6 x 1.0 64 82 30 B 32 22 18 M8 x 1.25 98 34 78 A A 40 18 22 40 86 M8 x 1.25 106 50 22 110 27 M10 x 1.5 46 130 B W 63 27 22 M10 x 1.5 124 142 58 B: Retraction locking F: Extension locking 80 33 28 M12 x 1.75 180 54 156 100 33 39 62 188 M14 x 2.0 210 23

C 0.2 B 0.2 A 0.2 Hexagon socket head mounting screws D Bore size (mm) A (mm) B (mm) C (mm) MGPM MGPL W 20 12 54 14 M5 x 0.8 24 72 25 18 15 M6 x 1.0 64 82 30 B 32 22 18 M8 x 1.25 98 34 78 A A 40 18 22 40 86 M8 x 1.25 106 50 22 110 27 M10 x 1.5 46 130 B W 63 27 22 M10 x 1.5 124 142 58 B: Retraction locking F: Extension locking 80 33 28 M12 x 1.75 180 54 156 100 33 39 62 188 M14 x 2.0 210 23

When using as a stopper, select a model with 30 stroke or less for bore sizes 20 and 25, and 50 stroke or less for bore sizes 32 to 100. 2. When selecting a model with a longer l dimension, be sure to choose a bore size which is sufficiently large.

7 N@4 CL1 A' A A' A MLGC CNG B MNB @5 !5 CNA CNS 20, 25: 50 stroke or less Over 100 stroke CLS CLQ Extension locking (Type F) Retraction locking (Type B) MLGP N#2 u #6 y @2 u #6 #2 y #5 @2 i i RLQ MLU ML1C D-X Section B-B' Section B-B' 20Section A-A' !6 !6 Section A-A' Data Component Parts Description Material Note No. !7 !8 !

When air with high purity is required, please either mount the above separator on the outlet side or use a made-to-order product (refer to page 14-19-50), which is provided with a micro mist separator (Series AWD) instead of a regulator. 3.

Diaphragm B moves to the right, and at the same time diaphragm A also moves to the right pushing pilot valve A. 3. When pilot valve A is pushed, air acts upon the switching valve, drive chamber A switches to a supply state, and the air which was in drive chamber B is exhausted to the outside. 4. When air enters drive chamber A, diaphragm B moves to the left pushing pilot valve B. 5.

Bulkhead female union P. 77 KCE Use for transit connection of a tube and a male screw for installation of panel. 74 Series KC Self-seal Fittings M5 Half union: KCH M5 Applicable tube O.D. (mm) Effective orifice(mm 2) Weight (g) A Thread R(PT) Part No. H (Hex.)

(Pitch) P=19 1/8 (A port) 21 46 Series SYJ700 Type 21R Manifold: Top Ported (External Pilot Type)/SS3YJ7-21RStations (-00) [ ] for AC Grommet (G) M5 x 0.8 (X port) 63.5 L2 L1 30.5 21.5 6 1.5 14 22.5 9.5 6 21.5 49 (DIN 50.3) 26 X P A A A A 43 71.2 [73.4] 2-5.5 (For mounting) R 1/4 (P, R port) 1/8 (A port) (Pitch) P=19 21 Manual override Approx. 300 (Lead wire length) (Station n) (Station

fitting R1/8, M5 x 0.8 2 1 6 One-touch fitting 5/32" One-touch fitting NPT1/8, M5 x 0.8 1/4" One-touch fitting M5 x 0.8 female thread is cut inside the pipe.

To use a floating joint to connect the cylinder rod to a driven body, secure it in place by applying a torque that is appropriate for the thread size. Also, if there is a risk of loosening during operation, take measures to prevent loosening, such as using a locking pin or thread adhesive.

To use a floating joint to connect the cylinder rod to a driven body, secure it in place by applying a torque that is appropriate for the thread size. Also, if there is a risk of loosening during operation, take measures to prevent loosening, such as using a locking pin or thread adhesive.