Actuator 10% Air 20% Air leakage 20% Other 50% Air blow Coolant 30% 70% Figure 1. Electric consumption Figure 2. Air consumption The point is 3:1. The pressure loss is suppressed and air consumption reduced by adjusting the effective sectional areas of the inlet side piping system and the nozzle side so that they are in the ratio of 3:1.
Flow ranges (lpm): 1-10, 5-50, 10-100, 20-200, 50-500; Port sizes (Rc, NPT, G): 1/8, 1/4, 3/8, 1/2 (flow range dependent); Rated pressure range (MPa): -0.05 to 0.5, or-0.05 to 0.75 (flow range dependent); Output options: 1-5V or 4-20mA; Accuracy: ±5% F.S.; Repeatability: ±1% F.S.
Flow ranges (lpm): 1-10, 5-50, 10-100, 20-200, 50-500; Port sizes (Rc, NPT, G): 1/8, 1/4, 3/8, 1/2 (flow range dependent); Rated pressure range (MPa): -0.05 to 0.5, or-0.05 to 0.75 (flow range dependent); Output options: 1-5V or 4-20mA; Accuracy: ±5% F.S.; Repeatability: ±1% F.S.
Indicator light Operating Range [mm] Auto switch model Bore size 16 20 25 32 40 50 63 D-M9NJ D-M9PJ 4.5 4.5 4.5 5 4.5 5 5 22 64.5 4 Since the operating range is provided as a guideline at room temperature, it cannot be guaranteed. It may change substantially depending on the ambient environment.
Open type, Dripproof/Rainproof, Splashproof /Low jetproof type 1 0 NBR FPM Metal material for wetted parts Enclosure 0 Open type 1 0 Brass, Phosphor bronze Dripproof/Rainproof type (Equivalent to IP42) 1 Stainless steel 304 Splashproof/Low jetproof type (Equivalent to IP44) 2 Port size 10 06 3/4 1 Thread type ON-flow range Note 1) IF30 is available for 06.
G Stainless steel Body material Applicable tubing O.D. 04 06 08 10 12 4 6 8 10 12 Body size 2 Elbow Type 2 3 4 5 6 M5 1/8 1/4 3/8 1/2 Control type Port size 0 1 Meter-out Meter-in M5 01 02 03 04 M5 x 0.8 R1/8 R1/4 R3/8 R1/2 With one-touch fitting 1
1% F.S. or less (at 25C water)?5% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2D 300/301(Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output Note 5) 1 to 5 VLinearity: ?2% F.S. or less, allowable load resistance: 100 k or moreCurrent output Note 6) 4 to 20 mALinearity: ?
1% F.S. or less (at 25C water)?5% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2D 300/301(Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output Note 5) 1 to 5 VLinearity: ?2% F.S. or less, allowable load resistance: 100 k or moreCurrent output Note 6) 4 to 20 mALinearity: ?
1% (Full span)Within 0.5% (Full span)Within ?0.5% (Full span)Within 0.2% (Full span)Within ?0.12% (Full span)/C?2%F.S. 1 digitkPa Note 5) Minimum display: 10 to 50C (No condensation)IP65350 g
1% F.S. or less (at 25C water)?5% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2D 300/301(Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output Note 5) 1 to 5 VLinearity: ?2% F.S. or less, allowable load resistance: 100 k or moreCurrent output Note 6) 4 to 20 mALinearity: ?
This product is not designed to be explosion proof. + 12 to 24 VDC 1 k Black OUT Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system.
fitting 1/4" One-touch fitting 5/16" One-touch fitting Possible to replace only the one-touch fitting.
5 to 60C Note 1)/?5 to 60C Note 1) (NBR seal)?5 to 60C Note 1)/?5 to 99C Note 1) (FKM seal)0.25 to 0.7 MPa?5 to 50C Note 1)Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)10.5 MPa?5 to 50C Note 1)20 times/minVertical upwards1/2?5.2 ?291/83.180
5 to 60C Note 1)/?5 to 60C Note 1) (NBR seal)?5 to 60C Note 1)/?5 to 99C Note 1) (FKM seal)0.25 to 0.7 MPa?5 to 50C Note 1)Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)10.5 MPa?5 to 50C Note 1)20 times/minVertical upwards3/4?6.2 ?3/81/45.6100
5 to 60C Note 1)/?5 to 60C Note 1) (NBR seal)?5 to 60C Note 1)/?5 to 99C Note 1) (FKM seal)0.25 to 0.7 MPa?5 to 50C Note 1)Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)10.5 MPa?5 to 50C Note 1)20 times/minVertical upwards3/8?3.9 ?151/8260
5 to 60C Note 1)/?5 to 60C Note 1) (NBR seal)?5 to 60C Note 1)/?5 to 99C Note 1) (FKM seal)0.25 to 0.7 MPa?5 to 50C Note 1)Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)10.5 MPa?5 to 50C Note 1)20 times/minVertical upwards3/8?3.9 ?151/8260
5 to 60C Note 1)/?5 to 60C Note 1) (NBR seal)?5 to 60C Note 1)/?5 to 99C Note 1) (FKM seal)0.25 to 0.7 MPa?5 to 50C Note 1)Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)10.5 MPa?5 to 50C Note 1)20 times/minVertical upwards3/8?8541/8260
5 to 60C Note 1)/?5 to 60C Note 1) (NBR seal)?5 to 60C Note 1)/?5 to 99C Note 1) (FKM seal)0.25 to 0.7 MPa?5 to 50C Note 1)Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)5.5 MPa?5 to 50C Note 1)20 times/minVertical upwards1/2?8.7 ?861/83.180
5 to 60C Note 1)/?5 to 60C Note 1) (NBR seal)?5 to 60C Note 1)/?5 to 99C Note 1) (FKM seal)0.25 to 0.7 MPa?5 to 50C Note 1)Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)5.5 MPa?5 to 50C Note 1)20 times/minVertical upwards1/2?8.7 ?861/83.180