Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: S (Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: N (NPT)
Function: 1 (2 Position Single), Body Option: 20 (Body Ported/Individual Pilot EXH), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: N (NPT), Option: F (Foot Bracket)
Size: 01(Size 26mm), Stations: 5 Stations, A, B Port: 03 (Side, 3/8), Port Thread: T (NPTF), SI Unit: SDZEN (EtherNet/IPâ„¢), End Plate: w/o SI Unit/End Plate, SI Unit COM: N (-COM), Number of Input Blocks: 4 Input Blocks, Type of Input Block: 2 (M12, 4 Inputs), Input Block COM: PNP or w/o SI Unit/Input Block
Size: 01(Size 26mm), Stations: 1 Station, A, B Port: 03 (Side, 3/8), Port Thread: Rc, SI Unit: SDZEN (EtherNet/IPâ„¢), End Plate: w/o SI Unit/End Plate, SI Unit COM: N (-COM), Number of Input Blocks: 1 Input Block, Type of Input Block: 2 (M12, 4 Inputs), Input Block COM: PNP or w/o SI Unit/Input Block
Size: 01(Size 26mm), Stations: 4 Stations, A, B Port: 02 (Side, 1/4), Port Thread: Rc, SI Unit: SDZEN (EtherNet/IPâ„¢), End Plate: w/o SI Unit/End Plate, SI Unit COM: N (-COM), Number of Input Blocks: 0 (w/o Input Block), Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block
Size: 01(Size 26mm), Stations: 8 Stations, A, B Port: 02 (Side, 1/4), Port Thread: Rc, SI Unit: SDZEN (EtherNet/IPâ„¢), End Plate: w/o SI Unit/End Plate, SI Unit COM: N (-COM), Number of Input Blocks: 0 (w/o Input Block), Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block
Size: 01(Size 26mm), Stations: 7 Stations, A, B Port: 02 (Side, 1/4), Port Thread: Rc, SI Unit: SDZEN (EtherNet/IPâ„¢), End Plate: w/o SI Unit/End Plate, SI Unit COM: N (-COM), Number of Input Blocks: 0 (w/o Input Block), Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block
Series: 344 (VP300), Pilot Type: R (External Pilot), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115VAC), 50/60Hz], Electrical Entry: L (L-type Plug Connector, 300mm Lead Wire Length), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: E (Push-turn Locking Lever Type), Port Size: 01 (1/8), Thread Type: N (NPT), Actuation
Series: 344 (VP300), Pilot Type: R (External Pilot), Pressure Specification: Standard (0.7MPa), Coil Specification: T (w/Power Saving Circuit, DC Only), Voltage: 5 (24VDC), Electrical Entry: LO (L-type Plug Connector w/o Connector), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 01 (1/8), Thread Type: N (NPT), Actuation Type: A (
Series: 344 (VP300), Pilot Type: R (External Pilot), Pressure Specification: K (High-pressure Type, 1.0MPa), Coil Specification: T (w/Power Saving Circuit, DC Only), Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal w/Connector), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 01 (1/8), Thread Type: N (NPT), Actuation Type: A
Series: 342 (VP300), Pilot Type: Internal Pilot, Pressure Specification: K (High-pressure Type, 1.0MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115VAC), 50/60Hz], Electrical Entry: D (DIN Terminal w/Connector), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 01 (1/8), Thread Type: N (NPT), Actuation Type: A (N.C., Normally
Series: 342 (VP300), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: T (w/Power Saving Circuit, DC Only), Voltage: 5 (24VDC), Electrical Entry: H (Grommet, 600mm Lead Wire Length), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 01 (1/8), Thread Type: N (NPT), Actuation Type: A (N.C., Normally
Series: 342 (VP300), Pilot Type: Internal Pilot, Pressure Specification: K (High-pressure Type, 1.0MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: L (L-type Plug Connector, 300mm Lead Wire Length), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 01 (1/8), Thread Type: N (NPT), Actuation Type: A (N.C., Normally
Series: 342 (VP300), Pilot Type: R (External Pilot), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 6 (12VDC), Electrical Entry: M (M-type Plug Connector, 300mm Lead Wire Length), Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 01 (1/8), Thread Type: N (NPT), Actuation Type: B (N.O., Normally Open
Series: 342 (VP300), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: T (w/Power Saving Circuit, DC Only), Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal w/Connector), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 01 (1/8), Thread Type: N (NPT), Actuation Type: A (N.C., Normally Closed
Series: 342 (VP300), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: T (w/Power Saving Circuit, DC Only), Voltage: 5 (24VDC), Electrical Entry: MO (M-type Plug Connector w/o Connector), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 01 (1/8), Thread Type: N (NPT), Actuation Type: B (N.O.
Series: 342 (VP300), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115VAC), 50/60Hz], Electrical Entry: L (L-type Plug Connector, 300mm Lead Wire Length), Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 01 (1/8), Thread Type: N (NPT), Actuation Type: A (N.C
Series: 342 (VP300), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115VAC), 50/60Hz], Electrical Entry: LO (L-type Plug Connector w/o Connector), Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 01 (1/8), Thread Type: N (NPT), Actuation Type: A (N.C., Normally
Series: 342 (VP300), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115VAC), 50/60Hz], Electrical Entry: LO (L-type Plug Connector w/o Connector), Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 01 (1/8), Thread Type: N (NPT), Actuation Type: B (N.O., Normally
Series: 342 (VP300), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: LO (L-type Plug Connector w/o Connector), Light & Surge Suppressor: U (Light & Surge Suppressor, Non-polar), Manual Override: Non-locking Push Type, Port Size: 01 (1/8), Thread Type: N (NPT), Actuation Type: A (N.C., Normally Closed