Please note, when selecting a product without an auto switch(es) (excluding those with built-in magnet), it is not possible to mount an auto switch(es) following receipt of the product from an SMC factory. Mounting Caution All models 1. In high humidity environments, keep the valve packed until the time of installation. 2.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, MUFFLER 1 PT, AIRLINE EQUIPMENT, AN SILENCER, HB, AN 1 INCH STANDARD (PT), .43503 lb, ModelEffective area mm2Sonic conductance C [dm3/(s?
Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 m or smaller. 1) These valves can be used without lubrication. 2) If a lubricant is used in the system, use class 1 turbine oil (no additives), ISO VG32. For details about lubricant manufacturers brands, refer to the SMC website.
IFW5 10 03 N 1 1 PSE Z I SE3 Diaphragm style flow switch PS Light 0 None Z I SE1 2 1 With neon light (110 VAC, Red) 2 With neon light (110 VAC, Green) Flow range ZSP 3 With neon light (220 VAC, Red) Low flow setting possible (1 l/min) 10 1 to 10 l/min 4 With neon light (220 VAC, Green) 20 10 to 20 l/min Simple flow setting Without removing the cover, you can set with a screwdriver from
Contact SMC representative for the applicable grease. 9/10 9-1. Model Selection 1 10/10 9-2.
(C) 55 50 60 70 80 IDU3D to 6D 45 50 55 65 75 IDU8D to 15C 45 50 55 65 70 IDU22C1, 37C1 40 45 50 55 60 IDU55C, 75C Ambient temperature (C) Outlet air pressure dew point (C) 15 10 5 15 10 5 15 10 5 15 5 10 5 15 10 1.35 1.35 0.60 1.35 1.35 0.60 1.35 1.35 0.60 1.35 0.60 1.35 0.60 1.35 1.35 25 1.35 1.05 0.50 1.35 1.05 0.50 1.35 1.10 0.50 1.35 0.60 1.20 0.55 1.35 1.25 30 1.25 0.95 0.45 1.25 0.95
Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 m or smaller. 3. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause the malfunction of pneumatic equipment, such as valves.
Install an air filter at the upstream side close to the impact blow valve. Select an air filter with a filtration degree of 5m or finer. 2. Take appropriate measures to ensure air quality, such as by providing an aftercooler, air dryer, or water separator.
Precautions on Selection 4 10. Precautions on Design 4 11. Mounting Methods 5 12. Piping 7 13. Operating Environment 8 14. Speed Control 8 15. Troubleshooting 9 16. How to exchange seals 10 17. Construction 12 18. Auto Switch 14 Series MGQ Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
An injury or failure can result. Caution (1) Pay attention to the length of time the auto switch will operate at an intermediate stroke position.
Install an air filter. When connecting piping to the product, refer to the catalog to avoid mistakes regarding the supply port, etc. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 m or smaller. Wiring 2. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator.
Install an air filter at the upstream side of valve. Select an air filter with a filtration degree of 5m or finer. 19 - 3. Install an aftercooler, air dryer or drain catch before the filter and take appropriate measures. Compressed air that contains excessive foreign material may cause malfunction of valves and other pneumatic equipment.
Install an air filter at the upstream side of valve. Select an air filter with a filtration degree of 5m or finer. 18 - 3. Install an aftercooler, air dryer or drain catch before the filter and take appropriate measures. Compressed air that contains excessive foreign material may cause malfunction of valves and other pneumatic equipment.
An application which could have negative effects on people, property, or animals requiring special safety An application which could have negative effects on people, property, or animals requiring special safety analysis. analysis. 4.Use in an interlock circuit, which Use in an interlock circuit, which Use in an interlock circuit, which Use in an interlock circuit, which requires the provision
Caution (1) Install an air filter. (4) When connecting the tubing, take pressure or possible changes to the tubing length into account, and allow a sufficient margin. Install an air filter at the upstream side of valve. Select an air filter with a filtration degree of 5m or finer. Failure to do so may result in fitting breakage or detachment of the tubing.
Our pressure switches do not have an explosion proof rating. Never use it in the presence of an explosive gas as this may cause a serious explosion. Panel Caution Panel mounting adapter A Panel mounting adapter B 1. Do not use in an environment with spattering liquid of oil or solvent. 2.
Please consult with SMC. 2) Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 m or smaller. 3) Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator.
Adopt an electrical circuit which will not cause chattering at the contact. The voltage variation must stay within the -10 to +10% range of the rated voltage.