For Water Digital Flow Switch Series PFW How to order PFW7 20 03 27 Integrated display type Flow rate range 0.5 to 4l/min 2 to 16l/min 5 to 40l/min 04 20 40 Unit specification Thread type Nil M With unit switching function Fixed SI unit Note) Rc NPT G Nil N F Wiring specification Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l 3m lead wire with connector Without lead wire
Housing Port Size (1/16 of an inch) Shaft Port Size (1/16 of an inch) Housing Port Configuration: 01 = Male NPTF(Non-Standard)* 02 = Female NPTF 03 = Male JIC 37 Degree 05 = Male SAE O-Ring Straight Thread 06 = Female JIC 37 Degree 07 = Female NPSM Pipe Swivel 10 = Female SAE Straight Thread JM = Seal-Lok Shaft Port Configuration: 01 = Male NPTF 02 = Female NPTF 03 = Male JIC 37 Degree 05
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in6R 3/8-03-06AS3211FG-03-06-03-06-03-06
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in10R 3/8-03-10AS3211FG-03-10-03-10-03-10
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in12R 3/8-03-12AS3211FG-03-12-03-12-03-12
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in10R 3/8-03-10AS3211FG-03-10-03-10-03-10
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in12R 3/8-03-12AS3211FG-03-12-03-12-03-12
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in6R 3/8-03-06AS3211FG-03-06-03-06-03-06
Element size Symbol 501S 601S Element size 190 x L440 190 x L770 Applicable model For FGFA For FGFB 268 High Precision Filter for Liquids Series FGH 1 Replacement Procedure is P.480 Replacement Parts and Seal List How to Order FGH 100 03 J002T Actuators Modular F.R.L.
FC2W-X110 How to Order Piping port size Flow rate control range Symbol Port size 03 3/8 0.5 to 4.0 L/min FC2W504 03 X110 3 2.0 to 16.0 L/min FC2W520 X110 3 04 Piping port size Lead wire 3 Lead wire with connector (3 m) Symbol Port size 04 1/2 Specications Model FC2W504-03-3-X110 FC2W520-04-3-X110 Applicable uid Water Flow rate detection method Karman vortex Flow rate control range 0.5 to
DC (+) 1 NC 2 Flow direction DC () 3 OUT 4 8 Digital Flow Switch for Water Series PFW How to order 20 03 27 PFW7 Flow rate range 0.5 to 4l/min 2 to 16l/min 5 to 40l/min 04 20 40 Wiring specifications 1l/min=0.0353SCFM 3m lead wire with connector Without lead wire Nil N Thread type Rc NPT G Nil N F Output specifications 27 67 NPN (2 outputs) PNP (2 outputs) Piping port size 03 04 06 3/8 1
VER2000 02 Series VER2000 AV AU 03 0 VER400 Series VER4000 AF Nil Thread type Pilot type Internal pilot External pilot 0 1 AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rc Nil Port size F N G NPT T IR Without sub-plate 03 04 06 3 8 1 2 3 4 NPTF VEX AMR ITV Note
Left IN1(P) Piping VHS500-06 VHS501-06 VHS400-04 VHS401-04 VHS400-03 VHS401-03 VHS400-02 VHS401-02 Right IN1(P) 3 4 1 2 3 8 1 4 Port size Effective area (mm2)(CV) Weight (kg) 93(5.22) 57(3.20) 35(1.97) 21(1.18) 105(5.90) 76(4.27) 54(3.03) 35(1.97) 0.29 1(P)2(A) 2(A)3(R) 0.34 0.25 0.27 Left or right to the front face of the handle.
Suitable for applications where copper free specifications are required, the in.?FGin. series can also be used in areas where wash down could degrade standard flow controls, such as food and packaging. This series is designed to offer the maximum control by increasing the number of turns of the needle to 10. The body and adjustment are made of high impact white resin for a clean look. This
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FILTER REGULATOR, MODULAR, AIRLINE EQUIPMENT, AW MASS PRO, EA, AW MASS PRO 3/8 MODULAR (PT), 1.10231 lb
This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc. The AW is part of the family of modular air preparation units and
Lightweight, compact, and precision control make these speed controls the right choice for many heavy-duty applications. These speed controls are offered with in-line and elbow construction to give the widest choice to your unique application. Locking nuts are included as standard as well as simplified mounting. Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MIST SEPARATOR, MODULAR, AIRLINE EQUIPMENT, AFM MASS PRO, EA, AFM 3/8INCH MODULAR (PT), .66138 lb, ModelPort sizeFluidProof pressureMaximum operating pressureMinimum operating pressureAmbient and fluid temperatureRated flow ( /min (ANR)) (1)Nominal filtration ratingOutlet side oil mist concentrationBowl
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MIST SEPARATOR, MODULAR, AIRLINE EQUIPMENT, AFM MASS PRO, EA, AFM 3/8INCH MODULAR (PT), 1.24508 lb, ModelPort sizeFluidProof pressureMaximum operating pressureMinimum operating pressureAmbient and fluid temperatureRated flow ( /min (ANR)) (1)Nominal filtration ratingOutlet side oil mist concentrationBowl
Series AFM modular style mist separator is available in body sizes 20, 30, and 40, and is offered with Rc, NPT or G thread types. The AFMs standard filtration is 0.3µm with a 99.9% filtered particle size. Body size 30 and 40 now have a transparent bowl guard that offers 360 visibility, while completely protecting the bowl from the environment. The modular design allows connection with