terminology 9 Assembly 10 Mounting and Installation 12 SI Unit Model Indication and How to Order 15 Summary of Product parts 15 Mounting and Installation 16 LED Display 17 Specification 19 Specifications 19 Dimensions 20 End Plate Model Indication and How to Order 21 Summary of Product parts 22 Mounting and Installation 24 Wiring 24 Specification 26 Specifications 26 Dimensions 27 Maintenance 33
The recommended bend radius of the lead wire is 6 times the outside diameter of the sheath, or 33 times the outside diameter of the insulation material, whichever is larger. Replace the damaged lead wire with a new one. Wire correctly. Incorrect wiring can break the product. Do not perform wiring while the power is on.
The recommended bend radius of the lead wire is 6 times the outside diameter of the sheath, or 33 times the outside diameter of the insulation material, whichever is larger. Replace the damaged lead wire with a new one. Wire correctly. Incorrect wiring can break the product. Do not perform wiring while the power is on.
The recommended bend radius of the lead wire is 6 times the outside diameter of the sheath, or 33 times the outside diameter of the insulation material, whichever is larger. Replace the damaged lead wire with a new one. Wire correctly. Incorrect wiring can break the product. Do not perform wiring while the power is on.
limiting RDYCOM 12 25 TLC RA3 Positioning completion READY 11 RD 49 24 INP RA4 PULSE F + 15 PP 10 PULSE F 16 PG 11 10 m or less NP 35 17 PULSE R + S/S NG 36 4 LA 18 PULSE R A phase pulse detector (Differential line driver) 9 PG0 LZ 8 5 LAR PG0 COM 10 LZR 9 6 LB B phase pulse detector (Differential line driver) LG 3 7 LBR Control common SD Plate 34 LG Control common 10 m or less Note 5) 33
Operation at occurrence of circulating fluid discharge pressure rise alarm RUN HIPRS ALARM(Alternately displayed) HRR Series 5.5 Advanced setting mode 5-33 HRX-OM-W002 Chapter 5 Display and Setting of Various Functions The user can decide the chiller behaviour if alarm "AL 09: circulating fluid discharge pressure rise" occurs.
Model Operating Conditions Plate non-rotating accuracy () Allowable plate rotation torque (T) Allowable lateral load (F) Non-rotating accuracy () Stroke 50 75 100 125 150 175 200 Load (N) Stroke 50 75 100 125 150 175 200 Torque (Nm) 42 2.87 0.09 42 2.47 40 2.17 + 42 2.38 32 2.16 24 1.98 17 1.82 F T F Refer to page 304 for deflection data. 240 33 Courtesy of Steven Engineering, Inc.-230 Ryan
If the cylinder piston does not reach the end of the stroke, locking might not work or locking might not be released. 33 1011Series CM2X Low speed cylinder Double acting single rod / 20, 25, 32, 40 How to Order Mounting style B L F G BZ Basic style Axial foot style Rod side flange style Head side flange style Boss-cut basic style Boss-cut rod side flange style Port thread type Clean series
The recommended bend radius of the lead wire is 6 times the outside diameter of the sheath, or 33 times the outside diameter of the insulation material, whichever is larger. Replace the damaged lead wire with a new one. Wire correctly. Incorrect wiring can break the Pressure switch. -6No.PS-OMX0002-A Do not perform wiring while the power is on.
gauge measurement value 16 bit No flag integer 32 to 47 SUP port pressure gauge measurement value 16 bit No flag integer 48 to 63 Distance measurement (guideline) displayed value 16 bit No flag integer Bit offset 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 Item Distance measurement (guideline) display value (16 bit With flag integer) Bit offset 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
Mounting orientation. 33 Series SZ3000 5 Port Solenoid Valve Precautions 2 Be sure to read before handling. Mounting 2. When fittings other than SMC fittings are used, follow the instructions of the respective fitting manufacturer. 5. Connection of piping to products. When connecting piping to a product, refer to its instruction manual to avoid mistakes regarding the supply port, etc.
L dimension 33 No. 510.5 34 523 35 535.5 36 548 37 560.5 38 573 39 585.5 40 598 41 610.5 42 623 43 635.5 Mounting screw tightening torques L dimension 44 648 45 660.5 46 673 47 685.5 No. 48 698 49 710.5 50 723 51 735.5 52 748 53 760.5 54 773 M2: 0.17 Nm M3: 0.8 Nm M4: 1.4 Nm L dimension 55 No. 785.5 56 798 57 810.5 58 823 59 835.5 60 848 61 860.5 62 873 63 885.5 64 898 65 910.5 L dimension
The recommended bend radius of the lead wire is 6 times the outside diameter of the sheath, or 33 times the outside diameter of the wire insulation material, whichever is larger. Replace any damaged lead wire with a new one. Wire correctly. Incorrect wiring can damage the product. Do not perform wiring while the power is on.
6th Floor, BG-1715 Sofia Czech Republic SMC Industrial Automation CZ s.r.o. (420) 541-426-611 Hudcova 78a CZ-61200 Brno Denmark SMC Pneumatik A/S (45) 70 25 29 00 Egeskovvej 1, DK-8700 Horsens Estonia SMC Pneumatics Estonia O (372)651-0370 Laki 12, EE-10621 Tallinn Finland SMC Pneumatiikka Finland Oy (358) 20 7513 513 PL72, Tiistinniityntie 4, SF-02231 Espoo France SMC Pneumatique S.A. (33
(f) (g) 3) Keep pressing until the 7-segment LED (f) is flashing. 33 No.JXC-OMU0030-A 4) Move the electric actuator slider to the position to register slowly using external force. 5) Keep pressing the set button (g) from the flashing state of the 7-segment LED (f) until it remains on, for (g) registration of the position.
CRBU2W30 90 CRBU2W40 90 Vane type Model (size) 180 270 90 180 270 90 180 270 90 180 270 180 270 Rotating angle Single vane Double vane Volume (cm3) 1.2 1.5 2.9 3.7 6.1 7.9 15 25 41 20.2 31.5 1 (0.6) 1.5 (1.0) 4.8 (3.5) 11.3 (8.5) Side ported M5 x 0.8 Port size Axial ported M5 x 0.8 M3 x 0.5 90 100 90 100 90 100 90 100 90 100 Rotating angle Caution Volume (cm 3) 1 1.1 2.6 2.7 5.6 5.7 14.4 14.5 33
Note 2) : Stations 01 to 16 33 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.
11 Features and Summary 11 System Configuration 12 System compatibility 13 How to Order 17 Summary of Product parts 18 EXW1-BMJA* 18 EXW1-RD* 21 Setting and Adjustment 27 Flow chart for operating the wireless system 27 I/O Configurator (NFC version) 28 Preparation 29 Installation of the software 29 Before starting the software 30 Download the I/O Configurator (NFC version) 33
Figure 5-33 Initial Setting Screen 3: Setting Confirmation (OUT) [Tips] To cancel a selection, press the [SEL] key, not [ENT] key. With the press of the [SEL] key, the cancellation takes effect and the screen is switched to the Menu screen 1. 7. Press the [SEL] key to display the Menu screen 1.
-port valve (A) 2(B) 4(A) A Note) 1(P) 5(R1) 3(R2) 4-position dual 3-port valve (B) 2(B) 4(A) B Note) 1(P) 5(R1) 3(R2) 4-position dual 3-port valve (C) 2(B) 4(A) C Note) 1(P) 5(R1) 3(R2) Note) Only rubber seal type Refer to the SMC website or the VQC1000/2000 series catalog (CAT.NAS11-101) for details on solenoid valve specifications, Common Precautions and Specific Product Precautions. 33