The circuit can be wired normally open or closed, with either AC or DC voltage and an optional micro load amperage. Optional indicator lights are also available. Any non-corrosive, non-flammable gas can be monitored. IP40 enclosure rating.
Flow ranges (lpm): 0-0.5, 0-1.0, 0-3.0, -0.5-0.5, -1.0-1.0, -3.0-3.0 (selectable from PFMV5); Analog input, sensor (DC): 1-5V; Analog output, monitor (DC): 1-5V or 4-20mA; Switch output modes: Hysteresis, window comparator, accumulation set point, accumulation pulse; Display accuracy: ±0.5% F.S.; Analog output accuracy: ±1% F.S.
Flow ranges (lpm): 0.2-10, 0.5-25, 1-50, 2-100 (selectable from PFM5 ranges); Analog input, sensor (DC): 1-5V or 4-20mA; Analog output (DC): 1-5V or 4-20mA; Switch output modes: Hysteresis, window comparator, accumulation set point, accumulation pulse; Display accuracy: ±0.5% F.S.; Analog output accuracy: ±0.3% F.S.
No lubrication is required. 3-port pilot operated poppet valve; Material restriction type; Low power consumption: 4.8W DC (standard type); 2W DC (energy-saving type); Possible to use in cacuum or under low pressure; Series 25A-VG342 is compatible with secondary battery applications
PFG3 is IP40 rated, and CE and RoHS compliant. 9 selectable flow ranges, plus custom user ranges; Analog input, sensor (DC): 1-5V or 4-20mA; Analog output, monitor (DC): 0-10V, 1-5V or 4-20mA; Switch ouput modes: Hysteresis, window comparator, accumulation set point, accumulation pulse, error, and OFF; Display accuracy: ±0.5% F.S.; Analog output accuracy: ±0.3% F.S.
PSE200A is CE and RoHS compliant, with an IP65 front face when panel mounted (IP40 otherwise). 12 selectable pressure ranges, plus custom user ranges; Analog input, sensor (DC): 1-5V or 4-20mA; Analog output, monitor (DC): 1-5V or 4-20mA; 10 pressure units: Pa, kPa, Ma, kgf/cm2, mbar, bar, psi, inHg, mmHg, mmH20; Display acuuracy: ±0.5% of F.S.; Display repeatablility: ±0.1% of F.S.
PSE300A is CE, C-RU-US and RoHS compliant, with an IP40 enclosure rating. 11 selectable pressure ranges, plus custom user ranges; Analog input, sensor (DC): 1-5V or 4-20mA; Analog output, monitor (DC): 1-5V or 4-20mA; 10 pressure units: Pa, kPa, Ma, kgf/cm2, mbar, bar, psi, inHg, mmHg, mmH20; Display acuuracy: ±0.5% of F.S.; Display repeatablility: ±0.1% of F.S.
Having the amplifier built into the electro-pneumatic pilot valve, only an external (24V DC) power supply and (1 to 5V DC) signal voltage need to be connected making handling simple. Using the VVEXB/2/4 series, a maximum 10 station manifold is possible.
Having the amplifier built into the electro-pneumatic pilot valve, only an external (24V DC) power supply and (1 to 5V DC) signal voltage need to be connected making handling simple. Using the VVEXB/2/4 series, a maximum 10 station manifold is possible.
The circuit can be wired normally open or closed, with either AC or DC voltage and an optional micro load amperage. Optional indicator lights are also available. Any non-corrosive, non-flammable gas can be monitored. IP40 enclosure rating.
The circuit can be wired normally open or closed, with either AC or DC voltage for a range of inductive or non-inductive loads. Choose bronze/brass or 316 stainless steel wetted parts to monitor vacuum for a range of gases and liquids. CE compliant option, with IP40 or IP44 enclosure rating. Model with indicator light also available.
Mechanical vacuum switch suitable for various gases and liquids; Vacuum range: -100 to -10 kPa; CE-compliant rated voltage: 110 VDC/220 VAC or less; Switch output is applied AC/DC circuit voltage for standard industrial loads; Repeatability: ±2 kPa; Hysteresis adjusting range: 7 to 53 kPa
PFG3 is IP40 rated, and CE and RoHS compliant. 9 selectable flow ranges, plus custom user ranges; Analog input, sensor (DC): 1-5V or 4-20mA; Analog output, monitor (DC): 0-10V, 1-5V or 4-20mA; Switch ouput modes: Hysteresis, window comparator, accumulation set point, accumulation pulse, error, and OFF; Display accuracy: ±0.5% F.S.; Analog output accuracy: ±0.3% F.S.
Flow ranges (lpm): 0.2-10, 0.5-25, 1-50, 2-100 (selectable from PFM5 ranges); Analog input, sensor (DC): 1-5V or 4-20mA; Analog output (DC): 1-5V or 4-20mA; Switch output modes: Hysteresis, window comparator, accumulation set point, accumulation pulse; Display accuracy: ±0.5% F.S.; Analog output accuracy: ±0.3% F.S.
PSE200A is CE and RoHS compliant, with an IP65 front face when panel mounted (IP40 otherwise). 12 selectable pressure ranges, plus custom user ranges; Analog input, sensor (DC): 1-5V or 4-20mA; Analog output, monitor (DC): 1-5V or 4-20mA; 10 pressure units: Pa, kPa, Ma, kgf/cm2, mbar, bar, psi, inHg, mmHg, mmH20; Display accuracy: ±0.5% of F.S.; Display repeatability: ±0.1% of F.S.
PSE200A is CE and RoHS compliant, with an IP65 front face when panel mounted (IP40 otherwise). 12 selectable pressure ranges, plus custom user ranges; Analog input, sensor (DC): 1-5V or 4-20mA; Analog output, monitor (DC): 1-5V or 4-20mA; 10 pressure units: Pa, kPa, Ma, kgf/cm2, mbar, bar, psi, inHg, mmHg, mmH20; Display accuracy: ±0.5% of F.S.; Display repeatability: ±0.1% of F.S.
PSE300A is CE, C-RU-US and RoHS compliant, with an IP40 enclosure rating. 11 selectable pressure ranges, plus custom user ranges; Analog input, sensor (DC): 1-5V or 4-20mA; Analog output, monitor (DC): 1-5V or 4-20mA; 10 pressure units: Pa, kPa, Ma, kgf/cm2, mbar, bar, psi, inHg, mmHg, mmH20; Display acuuracy: ±0.5% of F.S.; Display repeatablility: ±0.1% of F.S.
PSE300A is CE, C-RU-US and RoHS compliant, with an IP40 enclosure rating. 11 selectable pressure ranges, plus custom user ranges; Analog input, sensor (DC): 1-5V or 4-20mA; Analog output, monitor (DC): 1-5V or 4-20mA; 10 pressure units: Pa, kPa, Ma, kgf/cm2, mbar, bar, psi, inHg, mmHg, mmH20; Display acuuracy: ±0.5% of F.S.; Display repeatablility: ±0.1% of F.S.
PSE200A is CE and RoHS compliant, with an IP65 front face when panel mounted (IP40 otherwise). 12 selectable pressure ranges, plus custom user ranges; Analog input, sensor (DC): 1-5V or 4-20mA; Analog output, monitor (DC): 1-5V or 4-20mA; 10 pressure units: Pa, kPa, Ma, kgf/cm2, mbar, bar, psi, inHg, mmHg, mmH20; Display accuracy: ±0.5% of F.S.; Display repeatability: ±0.1% of F.S.
Flow ranges (lpm): 0.2-10, 0.5-25, 1-50, 2-100 (selectable from PFM5 ranges); Analog input, sensor (DC): 1-5V or 4-20mA; Analog output (DC): 1-5V or 4-20mA; Switch output modes: Hysteresis, window comparator, accumulation set point, accumulation pulse; Display accuracy: ±0.5% F.S.; Analog output accuracy: ±0.3% F.S.