Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Fixed SI Unit, Instruction Manual: None, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment Valve

Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment Valve

Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment Valve: ZS-33

Rated Pressure Range: 0.00 to -14.69 psi, Piping: ø6 One-touch Fitting, Output Specification: NPN Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: Unit Switching Function (Not Allowed for Use in Japan), Option: Panel Mount Adapter, Calibration Certificate: None, Lead Wire: 3m

Rated Pressure Range: 0.00 to -14.69 psi, Piping: ø6 One-touch Fitting, Output Specification: NPN Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: Fixed SI Unit; for Vacuum/Compound Pressure: kPa; for Positive Pressure: MPa, Option: Panel Mount Adapter+Front Protective Cover, Calibration Certificate: Calibration Certificate, Lead Wire: 3m

Rated Pressure Range: 0.00 to -14.69 psi, Piping: ø6 One-touch Fitting, Output Specification: NPN Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: Fixed SI Unit; for Vacuum/Compound Pressure: kPa; for Positive Pressure: MPa, Option: None, Calibration Certificate: Calibration Certificate, Lead Wire: 3m

Rated Pressure Range: 0.00 to -14.69 psi, Piping: ø6 One-touch Fitting, Output Specification: NPN Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: Unit Switching Function, Initial Value psi; Not Allowed for Use in Japan, Option: None, Calibration Certificate: None, Lead Wire: 3m

Rated Pressure Range: -14.50 to 14.50 psi, Piping: ø6 One-touch Fitting, Output Specification: NPN Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: Fixed SI Unit; for Vacuum/Compound Pressure: kPa; for Positive Pressure: MPa, Option: Panel Mount Adapter, Calibration Certificate: None, Lead Wire: 3m

Rated Pressure Range: -14.50 to 14.50 psi, Piping: ø6 One-touch Fitting, Output Specification: NPN Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: Fixed SI Unit; for Vacuum/Compound Pressure: kPa; for Positive Pressure: MPa, Option: None, Calibration Certificate: None, Lead Wire: 3m

Rated Pressure Range: 0.00 to -14.69 psi, Piping: ø6 One-touch Fitting, Output Specification: NPN Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: Fixed SI Unit; for Vacuum/Compound Pressure: kPa; for Positive Pressure: MPa, Option: Panel Mount Adapter, Calibration Certificate: None, Lead Wire: 3m

Rated Pressure Range: 0.00 to -14.69 psi, Piping: ø6 One-touch Fitting, Output Specification: NPN Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: Unit Switching Function, Initial Value psi; Not Allowed for Use in Japan, Option: Panel Mount Adapter, Calibration Certificate: None, Lead Wire: 3m

Rated Pressure Range: 0.00 to -14.69 psi, Piping: ø6 One-touch Fitting, Output Specification: NPN Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: Unit Switching Function (Not Allowed for Use in Japan), Option: Panel Mount Adapter+Front Protective Cover, Calibration Certificate: Calibration Certificate, Lead Wire: 3m

Rated Pressure Range: 0.00 to -14.69 psi, Piping: ø6 One-touch Fitting, Output Specification: NPN Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: Fixed SI Unit; for Vacuum/Compound Pressure: kPa; for Positive Pressure: MPa, Option: None, Calibration Certificate: None, Lead Wire: 3m

Piping: ø6 One-touch Fitting, Output Specification: NPN Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: Unit Switching Function, Initial Value psi; Not Allowed for Use in Japan, Option: None, Calibration Certificate: None, Lead Wire: 3m

Piping: ø6 One-touch Fitting, Output Specification: NPN Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: Unit Switching Function (Not Allowed for Use in Japan), Option: Panel Mount Adapter+Front Protective Cover, Calibration Certificate: None, Lead Wire: 3m

Piping: ø6 One-touch Fitting, Output Specification: NPN Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: Unit Switching Function (Not Allowed for Use in Japan), Option: Panel Mount Adapter, Calibration Certificate: None, Lead Wire: 3m

Piping: ø6 One-touch Fitting, Output Specification: NPN Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: Unit Switching Function, Initial Value psi; Not Allowed for Use in Japan, Option: Panel Mount Adapter, Calibration Certificate: None, Lead Wire: 3m

Piping: ø6 One-touch Fitting, Output Specification: NPN Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: Fixed SI Unit; for Vacuum/Compound Pressure: kPa; for Positive Pressure: MPa, Option: None, Calibration Certificate: None, Lead Wire: 3m

-A 1/4 R Left Note 1) Set pressure range of 6P (L, R, Z) is 0.2 to 0.6 MPa (30 to 90 psi).