SMC Corporation of America
Elite Part Number Search
Search Results "11-LEFSH32T7A-350"

, 11, 12 and 13, which can be ordered using the kit number for each cylinder bore size. 2 Series MHS2 2 Finger Air Gripper Gripping Point The work piece gripping point distance should be within the gripping force ranges given for each pressure in the effective gripping force graphs below.

Note 5) Refer to cautions on page 9 if IZN10E-11-(Female threads for piping) is used.

Moving Parts: With Magnet for Auto Switch [g] 100 Allowable lateral load at rod end [N] 80 Bore size [mm] Cylinder stroke [mm] 63 5 10 15 20 25 30 35 40 45 50 50 40 32 12 6 7 8 9 10 11 10.0 16 7 8 9 10 11 12 20 16 17 19 21 23 25 27 29 31 33 25 25 25 28 31 34 37 40 43 46 49 53 20 32 43 48 52 57 61 66 70 75 79 83 16 40 69 75 81 87 93 99 105 111 117 123 1.0 12 50 127 137 147 157 167 177 187

SET-ON 10 Start readiness signal CN2 24V DC + COM 1 COM 11 NO. 0 Indicates operation in progress when ON. ON when program is being executed and when returning to the home position. 2 BUSY 11 Operating signal NO. 1 12 NO. 2 3 <1> When this signal is OFF, an alarm is being generated for the actuator/controller.

Power Supply Cable. p. 11 Dustproof Filter. p. 11 Specific Product Precautions. . p. 12 4 HEF Series Cooling Capacity Calculation Air-cooled Example When cooling the object below a certain temperature in certain period of time.

-m;;:r~t 1~ 2M6 Screw depth 11 1 5 2-M6 Screw depth 11 ' ~ Lsii S ~ 60 L 4L.I Applicable clamp Part No. A cylinder , Maleual :Casl iron Malerial: Carbon steel I Matefial : Cast lIon . Part No.

Fluid Nil No L Yes Thread type*1 5 Steam Nil Rc A G B NPT Body material/Port size/Orifice diameter Symbol Body material Port size Orifice diameter A Bronze (CAC) *1 The thread type for the main piping and pilot piping is the same. 3/8 11 B 1/2 14 C 3/4 18 D Stainless steel 316L equivalent Pressure type 3/8 11 E 1/2 14 F 3/4 18 Nil Standard H High pressure Other Special Options Special Entry

VVZS3000-4-1 VVZS2000-4 14.4 x 12 x 1.2 7.5 x 4.5 x 1.5 VVZS2000-11-n (1) q Description Material Seal B Seal A NBR NBR NBR NBR Carbon steel Carbon steel Note 1) n: Stations Note 2) Manifold block assembly is attached with tie-rod for increasing stations. w e O-ring O-ring r t Tie-rod y Tie-rod for station addition VVZS2000-11-1-1 (2) Assembly part no.

G F 300 G F 280 G F Terminal part Flat terminal connector 11 23 9 H C 15 6.5 H C H C G1/2 Terminal: T DIN terminal: D Applicable cable O.D.: 6 to 12 G F G F Width across flats 22 G1/2 32 H (44) H 31.5 25 C C J G1/2 J Dimensions [mm] Model A B C D E F M P Q Grommet: G Grommet: GS Conduit: C Flat terminal: F DIN terminal: D Terminal: T G H G H G H G H G H J G H J XSA1-1P(N) 30 30 66 30 11

0.5 M4 x 0.7 7 35 + Stroke 35 + Stroke 7 Standard type: MQQT CC 40 + Stroke 8.5 13 to 17 M5 x 0.8 M6 x 1 45 + Stroke 9 RB 7.5 50 + Stroke 8 to 11 M3 x 0.5 65 + Stroke M4 x 0.7 7 J Anti-lateral load type: MQQL (Built-in ball bushing type) 70 + Stroke 5.5 80 + Stroke 8 13 to 17 M5 x 0.8 M6 x 1 D6.5 85 + Stroke 105 + Stroke 7 -X : Stroke 20Data 10-5-11 11 Series MQQ Dimensions Basic style (Through-hole

For details, refer to page 8-30-32. 8-20-11

(The selection should allow a sufficient margin because the value calculated by the selection software involves an error with reference to the actual value.) m3max m1max m2max Weight kg MY340 20 30 40 50 Collision deceleration G 1500 N 10 5 4 3 2 1 40 30 20 10 5 4 3 2 1 m3 max m1 max m2 max Weight kg 8-14-11 11 Series MY3A/3B Model Selection 2 Calculation of Guide Load Factor 1.

Enable Val165000 5 ON/OFF ON/OFF 10 4 Disable ON/OFF ON/OFF 0 11 83 1( 2Hold/Clear Via software 3PLC 4 5x1000 -48No.EX-OMS0026CN No.

Window of I/O Configurator (NFC version) 11 3.1. Basic characteristics 11 3.1.1. Login to administrator mode 13 3.2. Display for Wireless Base 14 3.2.1. Information tab 14 3.2.2. Input/Output monitor tab 16 3.2.3. Setting tab 20 3.3. Display for Wireless Remote 30 3.3.1. Information tab 30 3.3.2. Input/Output monitor tab 32 3.3.3. Setting tab 36 3.4.

Window of I/O Configurator (NFC version) 11 3.1. Basic characteristics 11 3.1.1. Login to administrator mode 13 3.2. Display for wireless master 14 3.2.1. Information tab 14 3.2.2. Input/Output monitor tab 16 3.2.3. Setting tab 20 3.3. Display for wireless slave 30 3.3.1. Information tab 30 3.3.2. Input/Output monitor tab 32 3.3.3. Setting tab 36 3.4.

No.EX-OMT0009 PRODUCT NAME PROFINET Compatible Fieldbus System MODEL / Series / Product Number EX500-GPN2 EX500-S103 EX500-DXP# Table of Contents Safety Instructions 3 Product Overview 9 System construction 9 EX500 GW unit Model Indication and How to Order 10 Summary of Product parts 10 Mounting and Installation 11 Installation 11 Wiring 12 LED Display 17 Hardware Configuration 18 Connection

Window of I/O Configurator (NFC version) 11 3.1. Basic characteristics 11 3.1.1. Login to administrator mode 13 3.2. Display for wireless master 14 3.2.1. Information tab 14 3.2.2. Input/Output monitor tab 16 3.2.3. Setting tab 20 3.3. Display for wireless slave 30 3.3.1. Information tab 30 3.3.2. Input/Output monitor tab 32 3.3.3. Setting tab 36 3.4.

Name Alarm flag 1,2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Unused 1 ERR01 System error 1 2 ERR02 System error 2 3 ERR03 Back-up data error Alarm flag 1 4-10 Unused 11 ERR11 DC power supply failure 12 ERR12 Internal temperature sensor High temperature failure 13 ERR13 Internal temperature sensor Low temperature failure 14 ERR14 Thermostat alarm Alarm given off status

(Refer to Table 11 (P21)) Before mounting a support bracket, make sure the product is aligned by placing on the leveled surface. It is recommended to secure the mounting screws temporarily to insure alignment before tightening with the specified torque. Fig 3. Order for tightening mounting screws 11 2-10.

Piping 11 10. Operating Environment 12 11. Speed Control 12 12. Clean Series / Precautions 13 13. Troubleshooting 17 14. Auto Switch 18 1 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.