SMC Corporation of America
Elite Part Number Search
Search Results "ZH20DSA-10-12-12"

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, IP65 (DC

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN, VALVE

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC

VY1 How to Order G Port size (IN, OUT) PPA 1/8 (Male thread), M5 x 0.8 (Female thread) 1/8 (Female thread) IN OUT 01 AL ARJ 3 10 01 BG ARJ 3 10 F BG With One-touch fitting 04 01 Option Body size 0.7 MPa setting (Standard) 0.2 MPa setting (1) Nil 1 S Model With seal Relieving type 10 Note 1) Compared with standard specifications, its adjusting spring has been only changed for 0.2 MPa.

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC

Reference) The recommended flow rate for one coolant (oil-based) element at a kinematic viscosity of 20 mm2/sec is the recommended flow rate when viscosity is equivalent to water (400 L/min) x flow coefficient (95%) = recommended flow rate 380 L/min at a kinematic viscosity of 20 mm2/sec. 20 Initial flow rate: Recommended setting range (Pressure drop: 7 to 10 kPa or less) 10 7 Pressure drop

Model XT13-394-06 XT13-394-10 INA-48-1-06 INA-48-1-10 INA-48-16-10 INA-48-16-06 INA-48-58-10-H INA-48-58-06-H Port size Rc3/4 Rc1 Rc3/4 Rc1 Rc3/4 Rc1 Rc3/4 Rc1 Relief mechanism Non-relief Relief Non-relief Fluid Deionized water (Pure water) Air, N2 Proof pressure 1.9 MPa 1.5 MPa Max. operating pressure 1.3 MPa 1.0 MPa Set pressure 0.1 to 1.0 MPa 0.05 to 0.5 MPa 5 to 60C Ambient and fluid

Seal NBR I-35S-A 12 x 8 x L42 I-36S-A 14 x 10 x L45 I-39S-A Note) Spare elements and O-rings for the cover are sold in sets of 10 pieces each. 13-10-4 2 Air Suction Filter With One-touch Fittings Series ZFB Application Example Flow Characteristics (Piping tube: Metric size, Inch size) Fluid Air Measured pressure Downstream Temperature Room release to temperature atmosphere (pressurized)

10 8 5 4 ZZMA Stations 04 ZQ 10 10 8 6 ZZMA Stations 04B Effective area of external silencer is 160 mm2.

Reference Heavy duty auto drain 6.3 Outer dimensions [IDF100F-30-W] Ball valve (O.D.10, Length approx. 2m) is also available.)

, 2m) ) 4 (10 4x ( 20 4x 25 2m) (10, 0.7m) (10,0.7m) 107 267 460 R2 735 64 75 7001 1120 R2 (17) 17) 40 127 479 51 1276 1418) (14~18) 1375 1,3 -W4 -W4 (-W4) (-W4) Y1/2 Y 1/2 () () R1/2 R1/2 (50) 20 (143) 335 7122 752 670 1,3 (-W5) -W5 -W5 (-W5) R1/2 R1/2 IDF100F150F-W 6 3 IDX-OM-Z004 6 IDF125F-30-W () K16K (10, 2m) (10 ) ( 4 4x JIS 65A 10K (K16K) 2m) 20 JIS 65A 10K

Crean class Amount of Type Speed recommended vacuum (mm/s) ISO 14644-1 Fed.Std.209D aspiration 6 1000 10 5 100 20 4 10 30 6 1000 50 5 100 60 4 10 70 6 1000 20 5 100 30 4 10 50 6 1000 30 5 100 70 4 10 90 600 11-LEJS40 1200 600 *Please aspirate it from the port on both sides when aspirating 50/min(ANR). Please select "D" about the type. 11-LEJS63 1200 * Based on SMC test condition.

Measure the amount of clean water which is dispensed 10 times continuously and convert it to one shot of dispensed volume. Repeat this measurement 10 times, and indicate the difference (%) between the average value of 10 sets of data (converted value of one shot) and the maximum and minimum values.

-32 nominal) M3 x 0.5 Port size Top ports M3 x 0.5 M5 x 0.8 (10-32 nominal) Deflection accuracy 0.03mm or less (0.0012") 2.

Option: Pressure gauge G15-10-01 How to Order NARM2000-4A2-N01G G15 P10 01 Symbol Units Nil MPa P PSI Common IN Individual IN IN M5 x 0.8 .39 (10) Max. pressure indication 10 150PSI (1.0MPa) .59 (15) IN OUT OUT *Pressure gauge for 30psig (0.2MPa) is not available.