SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ7-40-03-01T"

VV5FRA3-10-061-03 1 pc. VFRA3111 5 pcs. VVFS3000-10A 1 pc.

EX) VV5FRA4-10-061-03 1 pc. VFRA4111 5 pcs. VVFS4000-10A 1 pc. 3.2-23 VFRA4000 Dimensions 2 position single: VFRA4111-03 04 2 position double: VFRA421103 04 SlA VlA SlA VlA VM/VR VH 03 04 03 04 03 04 3 position closed center: VFRA43113 position exhaust center: VFRA44113 position pressure center: VFRA45113.2-24

Temperature setting (without writing EEPROM) No 02 31 32 35 30 30 03 3F 38 0D 06 0D Set at 25.0 deg.C 31 32 Reading internal sensor No 05 32 33 32 0D 02 32 32 35 30 32 03 3F 3B 0D Answer 25.02 deg.C 33 Reading external sensor No 05 33 33 33 0D 02 33 33 30 30 32 03 3F 38 0D Answer 30.02 deg.C 34 Reading alarm status No 05 34 33 34 0D 02 34 30 38 30 03 3C 3C 0D Answer ERR11 Answer -1.52 deg.C

The series is available in base mounted or body ported styles.Bar stock type manifold for SYJ7000 valves, Supply and exhaust ports common, Valves individually wired, Maximum 20 stations available as standard (types 21, 40, 41, 42); maximum 15 stations available as standard (type 20), 11 port sizes available, MANIFOLD BASE, 4/5 PORT SOLENOID VALVE, 0.19700 lb

;'16" 03/4" 'ol/2~ AsP330F'!U R(PT)1/8 M5 X 0.8 J\SP. 4;JOF~02 R(PT)I /4 Rc(PD1 /8 IIS'P530F:03 R(PT)318 Rc(PT)lIS 'ASi"!)30l"'lJ4 " R(PT)1!2 Rc(PT)1I4 ASP;l3OF:,FO~ RIPT)114 G(PF)1I8 I\Sps:ioFf;03' R(PT)318 G(PF)118 ),I'SPsJOF;;04: R(PT)1 /2 G{PF)1/4 A~P33!1F" 'l Il1 NPT1 /8 10-32UNF ,~Sp430FNO,?

VSA4220-01 VSA4220-02 VSA4220-03 VSA4320-01 VSA4320-02 VSA4320-03 VSA4420-01 VSA4420-02 VSA4420-03 2 position single VA 1 4 1 8 Rc 0.60 1 8 Rc 1 8 Rc SA 2 position double 1 4 1 8 Rc 0.70 1 8 Rc VA 1 8 Rc 3 position closed center 1 4 1 8 Rc 0.86 VM 1 8 Rc Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (

Page 4 last updated 11/03/03 10:05 AM Microprocessor-Controlled Electro-Pneumatic Regulator ITV2000 EASY PROGRAMMING GUIDE ADJUSTING THE MINIMUM AND MAXIMUM PRESSURES The ITV allows the user to customize the minimum pressure (zero point) at 0% input signal and the maximum pressure (span) at 100% input signal.

Refer to the following details of the kit. rThreaded Stud Kit for Manifold Part number Applicable model 4 stations 6 stations 8 stations 10 stations Metric size Inch size AS-1AB AS-3AB AS-5AB AS-7AB AS1002FS-23 AS1002FS-01 AS1002FS-04 AS1002FS-03 AS-4AB AS-6AB AS-8AB AS1002FS-06 AS-2AB AS-23AB AS1002FS-07 AS-9AB AS-10AB AS-11AB AS-12AB AS2002FS-04 AS2002FS-03 AS2002FS-06 AS2002FS-07 AS

(Request):010307F5 [CR][LF] (Response):01030E00D40D02010A [CR][LF] Request message Response message Code Contents Code Contents 01 Slave Address 01 Slave Address 03 Function 03 Function 0 Head address of specified register 0E Quantity of bytes to read 0007 Quantity of register to read 00D4 Information of 0h (circulating fluid discharge temperature) F5 LRC 0 Information of 0001h (Reserved)

(Request):010307F5 [CR][LF] (Response):01030E00D40D02010A [CR][LF] Request message Response message Code Contents Code Contents 01 Slave Address 01 Slave Address 03 Function 03 Function 0 Head address of specified register 0E Quantity of bytes to read 0007 Quantity of register to read 00D4 Information of 0h (circulating fluid discharge temperature) F5 LRC 0 Information of 0001h (Reserved)

M1 M2 Weight (g) ASV310F-01-06S ASV310F-01-08S ASV310F-02-06S ASV310F-02-08S ASV410F-01-08S ASV410F-01-10S ASV410F-02-08S ASV410F-02-10S ASV410F-03-08S ASV410F-03-10S ASV510F-02-10S ASV510F-02-12S ASV510F-03-10S ASV510F-03-12S ASV510F-04-10S ASV510F-04-12S 71.9 73.8 71.9 73.8 83.1 85.2 83.1 85.2 83.1 85.2 90.2 91.8 90.2 91.8 90.2 91.8 16.8 19.3 16.8 19.3 19.3 23.3 19.3 23.3 19.3 23.3 23.3

Symbol Body size Symbol Standard characteristics Symbol Port size Without sub-plate Rc 1/4 Rc 3/8 1 2 3 Nil 02 03 Symbol Set pressure range (MPa) 2 Without sub-plate Rc 1/4 Rc 3/8 Nil 02 03 03 04 06 0.05 to 0.65 MPa 1 2 2 Rc 1/4 Rc 3/8 Rc 1/2 Rc 3/8 Rc 1/2 Rc 3/4 0.1 to 0.9 MPa 2 02 03 04 03 04 06 1 3 30 Rc 3/8 Rc 1/2 Rc 3/4 4 0.005 to 0.15 MPa 1 1 4 45 1 2 3 4 12 8 4.5 2.5 Without sub-plate

03 03 03-3 3 3 3 0.1Nm 2 A B 1.7 ON OFF A B VQ1000 2 DC DC DC DC 2 ON OFF ON OFF 1.7 VQ20002 A B .


For the IR400-02/03/04□□: IR3000-02/03/04□□-A
For the IR401-02/03/04□□: IR3010-02/03/04□□-A
For the IR402-02/03/04□□: IR3020-02/03/04□□-A
For the IR412-02/03/04□□: IR3120-02/03/04□□ (IR-A series air operated regulators will be available at a later date.)
Note) Select option “H” when panel mounting the product.

: (952) 943-1299 Fax: (952) 943-1614 Austin Phone: (512)926-2646 Fax: (512) 836-1397 Romania Phone: 01-2552625 Fax: 01-2552630 Japan Phone: 03-3502-2740 Fax: 03-3508-2480 Malaysia Phone: 03-56350590 Fax: 03-56350602 Denmark Phone: 70252900 Fax: 70252901 Vancouver Phone: (604) 517-1646 Fax: (604) 517-1647 Nashville Phone: (615) 331-0020 Fax: (615) 331-9950 Boston Phone: (978) 326-3600 Fax:

Recommended flow rate Note) (l/min (ANR)) Internal capacity (cm3) 1.7 Mass (g) ZA Model IN side, OUT side 2 3.2 4 4 6 6 8 1/8" 5/32" 5/32" 1/4" 1/4" 5/16" ZFC050-02 ZFC050-23 ZFC050-04 ZFC100-04 ZFC100-06 ZFC200-06 ZFC200-08 ZFC051-01 ZFC051-03 ZFC101-03 ZFC101-07 ZFC201-07 ZFC201-09 2 7 10 10 20 30 50 7 10 10 20 30 50 4.9 ZX IN/OUT straight piping 1.7 4.3 ZR Metric size Easy installation

ASN AQ ASV AK How to Order VCHC F S 1 0 03 06 3 2 AS ASR ASQ Hexagon lock nut Round lock nut J Nil Lock nut option Speed controller Option None Electroless nickel plated Nil N Body size 1 2 3 4 M5 standard 01, 02 standard 03 standard 04 standard Tube size Note) With seal 04 06 08 10 12 4 6 8 10 12 Made to Order Refer to page 612 for details.