5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mA (within the flow rate range)Linearity: ?5% F.S. or less; allowable load resistance: 300 or less with 12 VDC, 600 or less with 24 VDC12 to 24 VDC (ripple ?10% or less)110 mA or lessIP65Operating: 0 to 50C, Stored: ?
Manifold base for VQZ200/300 body ported valves, Top mounted piping, Maximum 20 stations available as standard, 1/8 PT or NPT(VQZ200); 1/4 PT or NPT(VQZ300) P and R ports, Optional DIN rail mount, MANIFOLD, VALVE, VV3QZ* MANIFOLD VQZ 3-PORT, UJ, VV3QZ* BUILT IN FITTING ( 0.99208 lb
5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mA (within the flow rate range)Linearity: ?5% F.S. or less; allowable load resistance: 300 or less with 12 VDC, 600 or less with 24 VDC12 to 24 VDC (ripple ?10% or less)100 mA or lessIP65Operating: 0 to 50C, Stored: ?
5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mA (within the flow rate range)Linearity: ?5% F.S. or less; allowable load resistance: 300 or less with 12 VDC, 600 or less with 24 VDC12 to 24 VDC (ripple ?10% or less)100 mA or lessIP65Operating: 0 to 50C, Stored: ?
Stations: 05 (5 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 5 (Remote Sensor Unit), Rated Flow Range: 20 (2 to 16 L/min), Return Unit Components: Flow Adj.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Tie rod base, EX250 type manifold for SV2000 valve, Serial wiring with input/output unit, IP67 protection, Number of inputs/outputs: 32 each, Maximum 20 stations available as standard, Optional DIN rail mount, 6 port sizes available, MFLD, PLUG-IN, VALVE, SS5V2 MANIFOLD SV2000, UP, SS5V2 BUILT IN FITTING (
5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mA (within the flow rate range)Linearity: ?5% F.S. or less; allowable load resistance: 300 or less with 12 VDC, 600 or less with 24 VDC12 to 24 VDC (ripple ?10% or less)100 mA or lessIP65Operating: 0 to 50C, Stored: ?
5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mA (within the flow rate range)Linearity: ?5% F.S. or less; allowable load resistance: 300 or less with 12 VDC, 600 or less with 24 VDC12 to 24 VDC (ripple ?10% or less)100 mA or lessIP65Operating: 0 to 50C, Stored: ?
5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mA (within the flow rate range)Linearity: ?5% F.S. or less; allowable load resistance: 300 or less with 12 VDC, 600 or less with 24 VDC12 to 24 VDC (ripple ?10% or less)100 mA or lessIP65Operating: 0 to 50C, Stored: ?
5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mA (within the flow rate range)Linearity: ?5% F.S. or less; allowable load resistance: 300 or less with 12 VDC, 600 or less with 24 VDC12 to 24 VDC (ripple ?10% or less)110 mA or lessIP65Operating: 0 to 50C, Stored: ?
5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mA (within the flow rate range)Linearity: ?5% F.S. or less; allowable load resistance: 300 or less with 12 VDC, 600 or less with 24 VDC12 to 24 VDC (ripple ?10% or less)110 mA or lessIP65Operating: 0 to 50C, Stored: ?
Base mounted connector type plug lead manifold for VQZ**5* valve, Optional DIN rail mounting for ease of installation, Both 3 and 5 port valves can be mounted on the same manifold, Maximum 20 stations available as standard, 16 port sizes available, MFLD, 5-STA, VQZ1000 BASE MT, VALVE, VV5QZ* MANIFOLD VQZ 4/5-PORT, 2J, VV5QZ* NO SIZE RATING, .39600 lb
5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mA (within the flow rate range)Linearity: ?5% F.S. or less; allowable load resistance: 300 or less with 12 VDC, 600 or less with 24 VDC12 to 24 VDC (ripple ?10% or less)100 mA or lessIP65Operating: 0 to 50C, Stored: ?
5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mA (within the flow rate range)Linearity: ?5% F.S. or less; allowable load resistance: 300 or less with 12 VDC, 600 or less with 24 VDC12 to 24 VDC (ripple ?10% or less)100 mA or lessIP65Operating: 0 to 50C, Stored: ?
5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mA (within the flow rate range)Linearity: ?5% F.S. or less; allowable load resistance: 300 or less with 12 VDC, 600 or less with 24 VDC12 to 24 VDC (ripple ?10% or less)100 mA or lessIP65Operating: 0 to 50C, Stored: ?
Stations: 05 (5 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.
Stations: 05 (5 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: Flow Adj. Valve: None; Stop Valve: None, Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 05 (5 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: Flow Adj. Valve: None; Stop Valve: None, Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.