Low-Speed Rotary Actuator CRQ2X/MSQX Series CRQ2 Size: 10, 15, 20, 30, 40 MSQX Size: 10, 20, 30, 50 Possible to transfer a workpiece at low-speed. CRB2 CRB1 MSU CRJ CRA1 Realized a stable motion at 5 s/90.
Brown 2 A B-1 Cable length (L) Red 1 A A-1 Orange 6 B B-2 Yellow 5 B A-2 8 8m *1) Green 3 COM-A/COM B-3 A 10m *1) Blue 4 COM-B/ A-3 B 15m *1) Shield Cable color Terminal no. C 20m *1) Vcc B-4 Brown 12 GND A-4 Black 13 A B-5 Red 7 *1) Produced upon receipt of order. A A-5 Black 6 Only Robotic type cable can be selected.
Symmetric mounting Working principle A + A A Series CXS 6, 10, 15, 20, 25, 32 Reverse mounting Piston seal A A A R H R H 1. When the piston is retracting, air is exhausted through both A and A until piston seal H passes air passage A. 2. After piston seal H has passed air passage A, air is exhausted only through A.
Working principle A + A A Series CXS 6, 10, 15, 20, 25, 32 Reverse mounting Piston seal A A A R H R H 1. When the piston is retracting, air is exhausted through both A and A until piston seal H passes air passage A. 2. After piston seal H has passed air passage A, air is exhausted only through A.
Stroke B + Stroke L W G M K J Standard [mm] Bore size Stroke range Without magnet for auto switch With magnet for auto switch C D E F G H I J K L M N P Q W Z A B A B 50 10 to 50 37 29 42.5 34.5 15 18 57 9 M10 x 1.5 74 6.5 16 8 46 5.5 1/8 13 63.5 15 63 10 to 50 41.5 33.5 46.5 38.5 15 18 70 10 M10 x 1.5 88 6.5 16 8 56 5.5 1/8 14 76.5 15 80 10 to 50 49 40 55 46 21 22 89 12 M14 x 2.0 113
Connector A terminal no. B-1 A-1 B-2 A-2 B-3 A-3 Circuit Cable color Brown Red Orange Yellow Green Blue A A B B COM-A/COM COM-B/ 2 1 6 5 3 4 Cable color Connector D terminal no.
This pump has a sealless structure. Applicable model HRR050-A/W-40-T1 HRR050-A/W-40-T2 Rated flow50/60Hz common*1 L/min 16 24 Maximum pump head 50/60Hz common*2 m 50 Pump Output W 400 750 Circuit protector A 10 Recommended earth leakage breaker capacity A 10 Due to an increase in heat generation of the pump. The cooling reduces about 400W from the value in the catalog.
If an instantaneous flow of 10 L/min continues for 5 minutes, the accumulated flow will be 10 5 = 50 L. Accumulated flow external reset A function to reset the accumulated flow to zero by using an external signal. Accumulated pulse output A type of output where a pulse is generated every time a predefined accumulated flow passes.
AS22;1F-01-23(S)A 3.2 7.2 9 (9) AS22;1F-01-04(S)A 4 8.2 19.1 26.1 (26) 13.3 13 AS22;1F-01-06(S)A 19.1 6 1/8 10.4 11.6 30.6 29.2 27.5 26.1 10 (9) (12.7) AS22;1F-01-08(S)A 8 13.2 22.4 29.4 (29.3) 14.2 11 (10) AS22;1F-01-10(S)A 10 15.9 25.3 32.3 (32.2) 15.6 12 (11) AS22;1F-02-23(S)A 3.2 7.2 20.9 30 (30.3) AS22;1F-02-04(S)A 4 8.2 13.3 18 (19) 17 AS22;1F-02-06(S)A 22.6 6 1/4 10.4 12.6 23.4 32.5
Model CCVS CCVL -X Bore size (mm) Intermediate stop accuracy of CCVS: 50 mm/s x 0.015 sec. = 0.75 mm in case of 50 mm/s Fig. (5) Technical Data 1167 Air-hydro Unit CC Series How to Order The air-hydro unit consists of a converter and a valve unit that are compactly integrated.
2%4$2$4$5 @4 #0 Section A-A' 20A Data A' $0 $1 #4 #5 #2 @1 $6 $3 Component Parts No. Description Cam follower cap Magnet Magnet Seal magnet Rail End spacer Square nut Square nut Spring pin Parallel pin No.
132225 K 12 48 36 6.5 12 43.5 0.5 6.5 46 Z ZZ H G (NN 1) x H 26 10.5 26 10.5 A B 9.5 5.1 5.1 11 11 29 1.5 A B NN x M6 x 1 thread depth 12 6 5H9 ( ) depth 5 +0.030 0 GA HA B-B A-A 5H9 ( ) depth 5 +0.030 0 (mm) Model F 45 40 48 58 42 55 50 55 62 N 4 4 4 4 6 6 8 8 8 G 22 22 22 22 17 18 37 56 H 46 46 46 56 56 56 59 62 NN 2 2 2 2 3 3 4 4 4 GA 18 18 18 22 48 73 74 96 118 HA 50 50 50 56 48 56
T ground) HRSE012-A-20/23 1-phase 200V AC Lead wire end not Shared HRSE012-A-20/23-T (50/60Hz) 3 cores x 2.5mm2 treated with 100 V, 200 V HRSE018-A-20/23 (Bare cut) 15A 15A 30mA -23 Only (including HRSE018-A-20/23-T (L: Brown, N: Blue, PE:Green/Yellow) and 1-phase ground) HRSE024-A-20/23 230V 230V AC HRSE024-A-20/23-T (50/60Hz) HRSE Series 3.3 Installation 3-7 HRX-OM-R039 Chapter 3 Transport
40 40 50 62 3 4 5 8 10 12 9 10 11 8 10 12 16 20 24 20 22 29 33 43.5 51.5 19 21.5 23 33.5 34 34.5 8 5 to 50 11.5 5 to 50 H J L P Q QA R S SA T W Y Z Model ZC(D)UKD16 ZC(D)UKD20 ZC(D)UKD25 ZC(D)UKD32 ( ): In the case of a mounted auto switch.
Select a robotic cable (flexible cable) when repeated bending of the actuator cable is required. Also, do not put cables into a flexible moving tube with a radius smaller than the specified value (50 mm or longer). Electric shock, wire breakage, contact failure, or a loss of product control may occur if standard cables are used for repeated bending. 10. Confirm wiring insulation.
VQ550 Indicator light Indicator light 214 121.8 195 (200.5) 91.5 59.5 105.8 (Port A) 17.5 13.5 (Port B ) 2 2 73 (78.5) 122 106 59.5 (Port A) 17.5 13.5 (Port B) 2 4 SMC SMC 2 4 A B 40 53 66 162 50 41 37 31.5 18 A B A B 53 66 40 B A 1 3 5 14 12 35 53 2-6.5 Mounting hole Manual override 5 1 3 12 14 Manual override 35 53 2-6.5 Mounting hole G1/2 Electrical entry 18 31.5 37 41 50 98 G1/2 Electrical
How to Order EX9-FU EX510-DX EX510-DY3 EX510-DY4 10 Applicable model Rated current Rated insulation capacity Fuse resistance value 1 A 5 A Fuse rated current 48 VAC/DC 50 A 0.145 18 m 10 50 1 A 5 A 1721 Series EX510 Ordering Examples Shown is an example for ordering the EX510 series.
MA B D-F9BAL A Proper auto switch mounting positions (mm) 32 to 100 D-Z7, D-Z8, D-Y5 D-Y, D-Y7 D-Y7V, D-Y7WV D-Y7BAL B Bore size (mm) D-Z7 D-Z8 D-Y5 D-Y7 D-Y7W A 10 12 13 16.5 18.5 26.5 B 16.5 18.5 22.5 26 35 44.5 32 40 50 63 80 100 A B D-Y6 D-Y7V D-Y7WV Auto switch mounting heights (mm) SMC D-Y7BAL Bore size (mm) SMC MA 32 40 50 63 80 100 32.5 37 43 51.5 62 74.5 Approx.
Note) Operating range Note) 8.5 MY1MW 25, 32, 40, 50, 63 B A Solid state switch D-Y59 , D-Y69 , D-Y7P(V) D-Y7NW(V), D-Y7PW(V), D-Y7BW(V) A B A B Reed switch D-Z73, D-Z76, D-Z80 D-Y7BAL 40 32 25 Mounting position 25 Mounting position 32 40 50 63 25 Mounting position 32 40 50 63 139.5 184.5 229.5 278.5 323.5 A 139.5 184.5 229.5 139.5 184.5 229.5 278.5 323.5 A A 80.5 95.5 110.5 121.5 136.5