Cover Cushion Location E, F , G or H G B (Cushion Location Standard) C HEAD END CHART 1 Spare Parts and Repair Kit Item Quantity Description 11 1 Head 12 1 Cap 13 1 Barrel 14* 2 Barrel Seal 15 4 Tie Rods 16 4 Tie Rod Nuts 21 1 Piston (See Note1) 22 1 Piston Rod (See Note1) 24* 2 Piston Packings 26A 1 Piston Rod Assembly (See Note1) 28 1 Wear Band 31 1 Gland Bushing 32* 1 Gland Packing 33

Clean Room Specication Dimensions: Ball Screw Drive 11-LEFS16 (72) ( ) +0.025 0 3H9 depth 3 40 Body mounting Note 1) reference plane 4 x M4 x 0.7 thread depth 6.4 24 28 3.5 39.4 ( ) +0.025 0 3H9 depth 3 L Cable length 250 (37) A (Table traveling distance) Note 2) (110) 37 40 (41) [39] 39 [(41)] Stroke (2.4) 7 65 [Origin] Note 4) Origin Note 3) 27 4 [2] 2 [4] 9.2 Motor cable (2 x 5) 46 6 20 33

remote display unit type : Output from remote sensor unit type For Water P.12 16l/min 4l/min 100l/min 40l/min Flow rate measurement range l/min Integrated display type Remote type Output specifications Port size (Rc, NPT, G) Switch output Analog output Accumulated pulse output 3/8 1/2 1 3/4 Display unit Sensor unit PF2W504 520 540 511 PF2W704 720 740 711 0.5 to 4 PF2W30 2 to 16 5 to 40 33

Table Deflection ..,. .page 20 Working Range & Operating Conditions .pa9e 21 How To Order. .pages 22 & 23 How to Mount .Page 24 Dimensions. .pa9es 25 & 26 Specif ications/Construction/Parts List .page 27 Selection Chart & Duty Ratio .page 28 Kinetic Moment Allowance/Iable Deflection. ...,.page 29 Criteria of Accelerating Speed . .page 30 How To Order,. .pages 31 & 32 How to Mount .Page 33

The recommended bending radius of the lead wire is 6 times the outside diameter of the sheath, or 33 times the outside diameter of the insulation material, whichever is larger. 3. Do not tighten the handle with tools such as nippers. This can result in breakage due to idle turning. How to Use Pressure Sensor Assembly Handling Caution Connection Caution 1.

The recommended bend radius of the lead wire is 6 times the outside diameter of the sheath, or 33 times the outside diameter of the insulation material, whichever is larger. Replace the damaged lead wire with a new one. Wire correctly. Incorrect wiring may cause malfunction or damage to the product. Do not perform wiring while the power is on.

The recommended bend radius of the lead wire is 6 times the outside diameter of the sheath, or 33 times the outside diameter of the insulation material, whichever is larger. Wire correctly. Incorrect wiring can break the Pressure switch. Do not perform wiring while the power is on. Otherwise damage to the internal parts can result, causing malfunction.

14 35 26 18 13.6 2.7 depth 14 3/8 28 22 32 40 50 4.5 5 1.5 78 54 30 60 45.6 40.6 15.2 27 18 39 30 18 13.6 2.7 depth 12 3/8, 1/2 34 30 42 48 58 4.5 5 1.5 98 71 38 68 53.6 48.6 19.2 32 28 49 35 28 16.8 2.7 depth 12 1/2, 3/4 44 36 48 58 70 5.5 7 2.0 124 92 46 77 62.6 57.6 23.0 41 42 63 48 28 18.0 3.5 depth 14 3/4, 1 104 74 31 52 39.5 1 1/4, 1 1/2 PF3W721/521 108 76 56 91 76.6 71.6 28.5 54 33

Cover Cushion Location E, F , G or H G B (Cushion Location Standard) C HEAD END CHART 1 Spare Parts and Repair Kit Item Quantity Description 11 1 Head 12 1 Cap 13 1 Barrel 14* 2 Barrel Seal 15 4 Tie Rods 16 4 Tie Rod Nuts 21 1 Piston (See Note1) 22 1 Piston Rod (See Note1) 24* 2 Piston Packings 26A 1 Piston Rod Assembly (See Note1) 28 1 Wear Band 31 1 Gland Bushing 32* 1 Gland Packing 33

Note that when the SETON output is OFF, the AREA signal will also be OFF. *1) It maybe takes about ten seconds from turning on SVON to SVRE turned on when after the power supply. *2) The ALARM and ESTOP become the negative-true logic output. 33 - The change of output signal under the condition of the driver.

direction Port size Ventilation air inlet IDF3E-20 only Drain tube (O.D.10,length approx.0.8m) J L K [200VAC specification] [200VAC specification] Terminal block Power cable outlet(17) H P N M [100VAC specification] Power cable(Length:approx.1.9m) measure mm Model Port size A B C D E F G H J K L M N P Q IDF1E Rc3/8 69 101 270 32 21 330 IDF2E Rc3/8 51 232 138 24 327 IDF3E Rc3/8 473 67 304 33

1/8 28 7 28 7 ARJ Silencer (Option) 113 113 IN port 1/4 IN port 1/4 OUT port 1/4 AR425 to 935 23 27 23 27 OUT port 1/4 ARX 22 22 60 4 x 5.5 EXH port 1/4 40 60 4 x 5.5 8.5 AMR 70 50 70 (97) (When silencer installed: 107) (When high-noise reduction silencer installed: 126) ARM EXH port 1/4 ARP VBA11A-02 With elbow silencer (Option) 150 Pressure gauge (Option) IR-A Elbow silencer (Option) 33

Refer to the dimensions on page 15 for the mounting dimensions. (35) (25) 5.5 1.25 L Dimension [mm] No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 L 23 35.5 48 60.5 73 85.5 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5 248 260.5 No. 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 L 273 285.5 298 310.5 323 335.5 348 360.5 373 385.5 398 410.5 423 435.5 448 460.5

The recommended bend radius of the lead wire is 6 times the outside diameter of the sheath, or 33 times the outside diameter of the insulation material, whichever is larger. Replace a damaged lead wire with a new one. Wire correctly. Incorrect wiring can break the product. Do not perform wiring while the power is on.

+0.030 0 depth 6 26 D 30 5.5 63 73 12 Stroke + 181 Stroke + 198 10 43 4.5 4H9 +0.030 0 2-M3 x 0.5 (PE terminal) Cross section BB Motor wire (300mm) Effective thread depth 7 Photo micro sensor wire (300mm) M3 x 0.5 (PE terminal) 4H9 +0.030 0 Effective thread depth 4 3 6 Phillips binding head screw (included) 49 38 M3 x 4l Section C detail (Scale: 2/1) 7.5 Label Stroke + 104 Stroke + 121 33

212.5 197.5 13 9 235.5 225 208 14 L1 L2 L3 L4 L1 L2 L3 L4 L n 12 260.5 250 229 16 L n 12 273 262.5 239.5 17 10 235.5 225 208 14 11 248 237.5 218.5 15 13 273 262.5 239.5 17 14 285.5 275 250 18 15 285.5 275 260.5 12.5 16 298 287.5 271 13.5 10 248 237.5 218.5 15 11 260.5 250 229 16 13 285.5 275 250 18 14 285.5 275 260.5 12.5 15 298 287.5 271 13.5 16 310.5 300 281.5 14.5 L1 L2 L3 L4 L1 L2 L3 L4 33

Option) Heater (Option) (c) H J B A G A (b) C E Size 50, 63, 80 E C E Fn (KF flange) Fd (K flange) (a) D Heater (Option) Auto switch (Option) (c) H J K B A G A [mm] Model A B C D E*1 Fn Fd G H J K XLC-16-2 40 108 38 20 30 17 44 19 XLC-25-2 50 121 48 27 12 40 26 44 21 XLC-40-2 65 171 66 39 11 55 41 67 29 XLC-50-2 70 181 79 31 11 75 52 76 29 9 XLC-63-2 88 206 100 39 11 87 95 70 77 33

Please change the parameter in the initial setting. *3 The minimum unit of the travel distance of the actuator should be 1 [m]. *4 When the motor mounting position is right side parallel (LEY*R / LEYG*R) or left side parallel (LEY*L / LEYG*L), the rotation direction selection is 0(+: Counter motors side). -33- Recommended Value of acceleration time constant of Point table No.1 [LEY] LEY63

19.6 25 80 x (n-1) 70 10 25 Emitter cartridge n (Number of emitter cartridges), L Dimension L(mm) 300 380 620 780 1100 1260 1500 1900 2300 n Part no. 3 4 7 9 13 15 18 23 28 (Name plate position at 300 mm length) IZS31-300 IZS31-380 IZS31-620 IZS31-780 IZS31-1100 IZS31-1260 IZS31-1500 IZS31-1900 IZS31-2300 660 A Ionizer Series IZS31 Dimensions End bracket/IZS31-BE When mounted outside in (33

. + 4 x (n pcs. 1) 360.3 360.3 360.3 4 x R3 or less 4 x R3 or less 33 ZSE20(F)/ISE20 Series Function Details ZSE20C(F)/ISE20C(H) ZSE20B(F)/ISE20B ZSE20B(F)-L/ISE20B-L ZSE20A(F)/ISE20A ZSE20(F)/ISE20 Function Details Display examples of the main and sub (set value) screens of each mode.